28
Installing EB-Therm
Important EB-Therm must
not
be
installed where it may be exposed to
the following:
• direct sunlight and draughts.
• extreme fluctuations in temperature
or high air humidity.
The floor sensor should be mounted in
a spiral hose laid in the floor. The hose
endings should be sealed so that the
floor sensor can easily be replaced. All
tubes leading into the appliance box
must be sealed so that the air tempe-
rature sensor cannot be affected by
draughts.
Installation
Mount EB-Therm in a 65 mm standard
appliance box.
1. Make sure the box is level with the
wall.
2. Take off the front and frame by
pressing in the latch on the right-
hand side with a screwdriver or simi-
lar tool, as shown in the illustration.
3. Connect power, voltage 230 VAC,
load and any floor sensor cable. Any
extension to the floor sensor cable
must be by means of high-voltage
current. Protective conductors for the