EBARA PRA Operating And Maintenance Manual Download Page 3

3

EN

OPERATING AND MAINTENANCE MANUAL PART 2

THE USER SHOULD KEEP THIS DOCUMENT

1. INTRODUCTION

This instruction manual is split into two booklets: PART 1, 

containing general information regarding our whole product 

range;  and  PART  2,  containing  information  specific  to  the 

motor-driven pump you have purchased. The two publica-

tions are complementary to each other, so make sure you 

have both.

Comply with the instructions contained in them to get the 

most out of your motor-driven pump and assure its proper 

operation. If you need further information, get in touch with 

your nearest authorized dealer. 

If information in the two parts contradict each other, take 

PART 2 containing the product’s specific information as valid.

NO PART OF THESE ILLUSTRATIONS AND/OR TEXT MAY BE 

REPRODUCED FOR ANY REASON. 

The following symbols have been used in the compilation of 

this instruction booklet:

WARNING

Risk of damaging the pump or system

Risk of causing injury or damaging property

Electrical hazard

2. CONTENTS

1.  INTRODUCTION 

page 3 

2.  CONTENTS 

page 3 

3.  DESCRIPTION AND USE OF MOTOR-DRIVEN PUMP  page 3

4.  SPECIFICATIONS 

page 3

5.  PREPARING FOR USE 

page 3 

6.  DIAGRAMS AND DRAWINGS 

page 19 

3. DESCRIPTION AND USE OF MOTOR-DRIVEN PUMP

3.1. DESCRIPTION

Description

MOTOR-DRIVEN SURFACE PUMP

MODEL / Type

PRA-PRI / Peripheral

3.2. USE FOR WHICH PUMPS ARE DESIGNED

For domestic use (gardening, fountains), for feeding boilers, 

pressure vessel units, industrial, sanitary and air-condition-

ing applications. Suitable for drawing water from primary 

storage tanks or well with a difference in level of 2-3 m.

Use the motor-driven pump based on its technical specifica

-

tions.

3.3. USE FOR WHICH PUMPS ARE NOT DESIGNED

Pumps cannot be used to handle dirty water, water contain-

ing acids and corrosive liquids in general, water with tem-

peratures higher than those mentioned in chap. 4, saltwater, 

flammable liquids and hazardous liquids in general.

The motor-driven pumps must never be made to work with-

out liquid.

4. SPECIFICATIONS

4.1. PRA - PRI PUMP SPECIFICATIONS

U/M

PRA

PRI

Max. temperature 

of liquid pumped 

°C

80

90

Suction diameter

*

G1

Delivery diameter
Maximum working 

pressure

MPa

0.6 (0.50)

0.75 (0.80)

1.2 (1.00-1.50-2.00)

* = threading according to ISO 228

4.2. MOTOR SPECIFICATIONS

TYPE

TEFC

RATINGS

See motor-driven pump rating plate

OVERLOAD 

PROTECTION

SINGLE PHASE: unless otherwise 

stated on the additional sheet, 

thermal cutout w/ automatic reset

THREE PHASE: by installer

4.3. INFORMATION ON AIRBORNE NOISE

Pump

P2

[kW]

Shaft height

LpA [dB]*

PRA/PRI

0.3÷0.45

63

<70

0.6-0.75

71

1.1-1.5

80

73

The table gives maximum sound emission values for the mo-

tor-driven pumps

*  Sound pressure level - Mean value of measurements 

taken one metre from the pump. Tolerance ± 2.5 dB.

5. PREPARING FOR USE

5.1. FILLING THE PUMP

WARNING

   OPERATION TO BE PERFORMED WITH THE 

MOTOR’S TERMINAL STRIP FULLY CLOSED.

PRA-PRI 

a)   Unscrew the hexagonal cap (1) (chap. 6 FIG. 1) located on 

the fron t of the pump casing at the top;

b)   with the aid of a funnel, fill the pump casing with water to 

overflowing;

c)   screw the hexagonal cap back on until it is locked tight to 

prevent air getting in.

5.2. STARTING DIAGRAM (FIG.2)

To put the pump into operation, you must proceed as fol-

lows:

a)   Insert a flat-tip screwdriver through the fan cover, in the 

back of the pump, until it fits into the slot made on the 

end of the rotor shaft;

b)   Turn the screwdriver a couple of complete turns both 

ways;

c)  Connect the pump to the system.

Summary of Contents for PRA

Page 1: ...ISNING Brugs og vedligeholdelsesanvisninger 8 PINTA ASENNETTAVA S HK PUMPPU PRA PRI K NN S ALKUPER ISEST OHJEET K ytt ja huolto ohjeosa 2 9 ELEKTRISCHE OPPERVLAKTEPOMP PRA PR VERTALINGVANDEOORSPRONKEL...

Page 2: ...no utilizzabili per movimentare acqua sporca acqua con presenza di acidi e in genere liquidi corrosivi acqua con temperature superiori a quanto riportato nel cap 4 acqua di mare liquidi infiammabili e...

Page 3: ...technical specifica tions 3 3 USE FOR WHICH PUMPS ARE NOT DESIGNED Pumps cannot be used to handle dirty water water contain ing acids and corrosive liquids in general water with tem peratures higher t...

Page 4: ...R VU Ne pas les utiliser pour acheminer de l eau sale de l eau contenant des acides et en g n ral des liquides corrosifs de l eau ayant une temp rature sup rieure celles report es au chap 4 de l eau d...

Page 5: ...NICHT VORGESEHENE VERWENDUNG Nicht einsetzbar f r die Bewegung von Schmutzwasser Wasser das S uren oder tzende Fl ssigkeiten im Allge meinen enth lt Wasser mit Temperaturen die die in Kap 4 angegebene...

Page 6: ...MPLEO NO PREVISTO No se pueden utilizar para mover agua sucia agua con pre sencia de cidos y por lo general l quidos corrosivos agua con temperaturas superiores a lo indicado en el cap 4 agua de mar l...

Page 7: ...FT Kan inte anv ndas f r att s tta i r relse smutsigt vatten vatten som inneh ller syror och i allm nhet korrosiva v ts kor vatten med temperaturer som verstiger anvisningarna i kap 4 havsvatten ant n...

Page 8: ...3 UFORUDSET BRUG Elektropumperne kan ikke benyttes til h ndtering af snavset vand vand med syreindhold og tsende v sker i alminde lighed vand med en temperatur der overstiger anvisninger ne i kap 4 ha...

Page 9: ...pumpata likaista vett hap poa sis lt v vett eik yleens k n korrosoivia nesteit eik my sk n vett jonka l mp tila ylitt kohdassa 4 m ritellyt arvot merivett helposti syttyvi nesteit eik muitakaan vaaral...

Page 10: ...oor het verplaatsen van vuil water water waarin zich zuren en over het algemeen bijtende vloeistoffen bevinden water met hogere tempera turen dan aangegeven in hfdst 4 zeewater brandbare en over het a...

Page 11: ...TO N o podem ser utilizadas para movimentar gua suja gua com cidos e em geral l quidos corrosivos gua com tem peraturas superiores ao indicado no cap 4 gua do mar l quidos inflam veis e em geral perig...

Page 12: ...6 19 3 3 1 PRA PRI 3 2 2 3 m 3 3 4 4 4 1 PRA PRI PRA PRI C 80 90 G1 MPa 0 6 0 50 0 75 0 80 1 2 1 00 1 50 2 00 UNI ISO 228 4 2 T E F C 4 3 P2 kW LpA dB PRA PRI 0 3 0 45 63 70 0 6 0 75 71 1 1 1 5 80 73...

Page 13: ...n vody vody s obsahem kyselin a obecn rav ch kapalin vody s teplotou vy ne hodnoty uveden v kap 4 mo sk vody a ho lav ch kapalin a nebezpe n ch kapalin obecn Elektrick erpadla nesm j b t nikdy uv d na...

Page 14: ...ITIE Nem u by pou it pre erpanie zne istenej vody vody s obsahom kysel n a v eobecne ierav ch kvapal n vody s teplotou vy ou ako hodnoty uveden v kap 4 morskej vody hor av ch a v eobecne nebezpe n ch...

Page 15: ...ZAKAZ U YTKOWANIA ELEKTROPOMP Nie wolno stosowa pomp do przepompowywania wody zabrudzonej z zawarto ci kwas w oraz p yn w powoduj cych korozj wody w temperaturze wy szej ni podana w rozdziale 4 wody m...

Page 16: ...4 16 5 16 6 19 3 3 1 PRA PRI 3 2 2 3 3 3 4 4 4 1 PRA PRI PRA PRI C 80 90 G1 0 6 0 50 0 75 0 80 1 2 1 00 1 50 2 00 UNI ISO 228 4 2 4 3 P2 LpA PRA PRI 0 3 0 45 63 70 0 6 0 75 71 1 1 1 5 80 73 2 5 5 5 1...

Page 17: ...KULLANIM Kirli suyu asit ve genelde a nd r c s v mevcudiyetli suyu s cakl 4 b l mde a klanm s cakl a an suyu deniz suyunu yan c ve genelde tehlikeli s v lar y kseltmek i in kullan lamazlar Elektro po...

Page 18: ...PRA PRI 3 2 2 3 3 3 4 4 4 1 PRA PRI PRA PRI 80 90 C G1 0 6 0 50 0 75 0 80 1 2 1 00 1 50 2 00 MPa UNI ISO 228 18 18 18 18 18 19 4 2 T E F C 4 3 LpA dB P2 kW 63 0 3 0 45 70 71 0 6 0 75 73 80 1 1 1 5 PRA...

Page 19: ...SINS 6 PL NE UND ZEICHNUNGEN 6 ESQUEMAS Y PLANOS 6 SCHEMAN OCH RITNINGAR 6 DIAGRAMMER OG TEGNINGER 6 KAAVIOT JA KUVAT 6 SCHEMA S EN TEKENINGEN 6 ESQUEMAS E DESENHOS 6 6 SCH MATA A V KRESY 6 SCH MY A V...

Page 20: ......

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...el 48 22 3909920 Fax 48 22 3909929 e mail mktgpl ebaraeurope com EBARA Pumps Europe S p A GERMANY Elisabeth Selbert Stra e 2 63110 Rodgau Germany Tel 49 0 6106 66099 0 Fax 49 0 6106 66099 45 e mail mk...

Reviews: