P.23
PM10U
EBARA
CORPORATION
4.3 Electric Wiring
This product is not equipped with earth leakage breaker (ELB) and emergency off switch (EMO). Follow
the local regulations when installing this product.
Use adequate earth leakage breaker which
corresponds to the specifications below if necessary.
※
Use this pump with protective equipment pursuant to “About Safety Standard of The Pump”, in P.7,
when operate it according to the oversea safety standard.
Table 4.1 Power supply and capacity of breaker
EV-A03
Single phase
3 phase
Note 1
)
Type
EV-A03-1 EV-A03-2 EV-A03-3
Power supply [50/60 Hz]
100-120 V
Note 2
)
200-240 V
200-240 V
Rated Voltage
125 V or more
250 V
250 V
Rated Current
15 A
10 A
5 A
Earth
leakage
breaker
Rated Sensitivity
Current
30 mA
Note 1) The pump model is different depending on the power supply specification.
Note 2) Use this pump pursuant to the voltage range stated in P.7, “About Safety Standard of The
Pump”, when operate it according to the oversea safety standard.
DANGER
Turn off the main switch on the pump and disconnect power cable before servicing. Do not
supply power before completion of service work.
WARNING
Wiring work must be done by qualified workers.
For US installations, the EV-A03 dry pump should be installed downstream of a UL Listed Branch
Rated Circuit Breaker (Listed to UL 489) or a set of UL Listed Branch Rated fuses.
For CE installations, the EV-A03 dry pump should be installed downstream of a CE Approved Circuit
Breaker (Approved to IEC 60947-2) or a set of CE Approved Branch Rated fuses (Approved to IEC
60269.)
Connections of the dry pumps to a facility wiring system or host system must be in accordance with all
applicable wiring practices described in the National Electric Code (for US Installations only) or all
applicable facility wiring practices for the European Union (for EU installations only).