32
EN
5.18
5.35
5.36
5.37
5.38
5.39
5.40
5.19
5.27
5.23
5.31
5.22
5.30
5.26
5.20
5.28
5.24
5.32
5.21
5.29
5.25
5.33
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
0,5
0,5
0,5
0,5
See parameter 5.18
See parameter 5.18
See parameter 5.18
10
10
10
10
-100
-100
-100
-100
FS
FS
FS
FS
65
65
65
65
200
200
200
200
Not used
Par 1,1
Par 1,1
25
25
50
50
Bar
Bar
Hz
Hz
ºC
ºC
4
4
4
4
Not used
Not used
Not used
25
25
25
25
Bar
Bar
Bar
Bar
Hz
Hz
Hz
Hz
ºC
ºC
ºC
ºC
Not used
Total Stop
Total Stop INV
Local Stop
Local Stop INV
IN Setpoint
IN Setpoint INV
Flow Sensor
Flow Sensor INV
Slave 0-10V
0,5
0,5
25
25
Par. 5.06
Par. 5.06
Par. 5.05
Par. 5.05
65
65
Par. 5.07
Par. 5.07
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Selecting “Not used” will not affect the system.
We can use the digital input as a system start-stop or
only one pump start-stop choosing the Total Stop or Local
Stop options.
It can also be used as a different default set pressure in
the same way. Choosing IN Setpoint you can be select
another different set pressure on parameter 5.19.
Flow Sensor option is used when a flow sensor is
available, which will stop the pump.
Slave 0-10V option is used if a 0-10V active device or
a potentiometer (passive device) is connected to the
0-10V input.
Note:
INV options are used for NC inputs.
If a 0-10V device is installed, here you can set the
pressure value for the 1 volt signal.
*This parameter is available when any of the digital
input is set to Slave 0-10V.
If a 0-10V device is installed, here you can set the
pressure value for the 9 volt signal.
*This parameter is available when any of the digital
input is set to Slave 0-10V.
If a 0-10V device is installed, here you can set the speed
value for the 1 volt signal.
*This parameter is available when any of the digital
input is set to Slave 0-10V.
If a 0-10V device is installed, here you can set the speed
value for the 9 volt signal.
*This parameter is available when any of the digital
input is set to Slave 0-10V.
If a 0-10V device is installed, here you can set the
temperature value for the 1 volt signal.
*This parameter is available when any of the digital
input is set to Slave 0-10V.
If a 0-10V device is installed, here you can set the
temperature value for the 9 volt signal.
*This parameter is available when any of the digital
input is set to Slave 0-10V.
A different setpoint can be set if the input is active.
A different setpoint can be set if the input is active.
A different setpoint can be set if the input is active.
A different setpoint can be set if the input is active.
See parameter 5.18
See parameter 5.18
See parameter 5.18
DIGITAL INPUT 1
SLAVE 1V
PRESSURE SETPOINT
SLAVE 9V
PRESSURE SETPOINT
SLAVE 1V
SPEED SETPOINT
SLAVE 9V
SPEED SETPOINT
SLAVE 1V
TEMPERATURE SETPOINT
SLAVE 9V
TEMPERATURE SETPOINT
PRESSURE IN 1
PRESSURE IN 3
PRESSURE IN 2
PRESSURE IN 4
DIGITAL INPUT 2
DIGITAL INPUT 4
DIGITAL INPUT 3
SPEED IN 1
SPEED IN 3
SPEED IN 2
SPEED IN 4
TEMPERATURE IN 1
TEMPERATURE IN 3
TEMPERATURE IN 2
TEMPERATURE IN 4
E
D
C
B
A
Max.
Min.
Default
Units
Description
Par.
Programming
Application
Notes
Summary of Contents for E-SPD MT 2200
Page 2: ......
Page 40: ......
Page 78: ......
Page 116: ......
Page 154: ......
Page 192: ......
Page 230: ......
Page 268: ......
Page 306: ......
Page 344: ......
Page 391: ......
Page 392: ...392 7 SCHEMATIC DIAGRAM TT 11000 2 3 4 12 1 13 11b 11a 11b 7 9 15 14 8 17 5 6 16 10 ...
Page 395: ......