EBARA 6WY Original Instructions Manual Download Page 24

EBARA

 

Pumps Europe S.p.A.

Via Torri di Confine 2/1 int. C 

36053 Gambellara (Vicenza), Italy

Phone: +39 0444 706811

Fax: +39 0444 405811

[email protected]

www.ebaraeurope.com

Rev. A 05/2021

EBARA Pumps Europe S.p.A. UK

Unit A, Park 34

Collett Way - Didcot

Oxfordshire - OX11 7WB, United Kingdom

Tel.: +44 1895 439027 - Fax +44 1235 815770

e-mail: [email protected]

EBARA Pumps Europe S.p.A. FRANCE 

122, Rue Pasteur 

69780 Toussieu, France 

Phone: +33 04 72 76 94 82

Fax +33 08 05 10 10 71 

e-mail: [email protected]  

EBARA POMPY POLSKA Sp. z o.o.

ul. Działkowa 115 A

02-234 Warszawa, Poland

Tel. +48 22 3909920 - Fax +48 22 3909929

e-mail: [email protected]

EBARA Pumps Europe S.p.A. GERMANY

Elisabeth-Selbert-Straße 2

63110 Rodgau, Germany

Tel. +49 (0) 6106 66099-0

Fax +49 (0) 6106 66099-45

e-mail: [email protected]

EBARA Pumps RUS Ltd.

Prospekt Andropov 18, building 7, floor 11 

115432 Moscow

Tel. +7 499 6830133 

e-mail: [email protected]

EBARA PUMPS IBERIA, S.A. 

Poligono Ind. La Estación - C/Cormoranes 6-8 

28320 Pinto (Madrid), Spain 

Phone +34 916.923.630 - Fax +34 916.910.818 

e-mail: [email protected] 

Roberto Massignani 

Product Maintenance 

R&D dept. 

EBARA PUMPS SOUTH AFRICA (PTY) LTD

26 Kyalami Boulevard,Kyalami Business Park,

1684, Midrand, Gauteng

South Africa

Phone: +27 11 466 1844

Fax: +27 11 466 1933

EBARA PUMPS SAUDI ARABIA LLC 

St. 98, Dammam Second Industrial City,

P.O.Box. 9210, 

Dammam 34333, Kingdom of Saudi Arabia 

Phone 966-138022014 

Summary of Contents for 6WY

Page 1: ...WY EBARA ISTRUZIONI ORIGINALI Manuale d uso e manutenzione 2 SUBMERSIBLE MOTOR 6WY EBARA ORIGINAL INSTRUCTIONS User s Maintenance Manual 6 MOTOR SUMERGIDO 6WY EBARA INSTRUCCIONES ORIGINALES Manual de...

Page 2: ...icare visivamente l integrit del motore per individuare eventuali danni subiti durante il trasporto Controllare che la potenza del motore e il voltaggio siano quelli di utilizzo Controllare che l albe...

Page 3: ...te le movimentazioni a non danneggiarlo e soprattutto a non sollevare il motore afferrandolo per il cavo Assemblare il motore con la pompa verificando che l albero giri liberamente e mettere del grass...

Page 4: ...vo deve essere del tipo idoneo per motori sommersi La tabella a pagina 14 indica le massime lunghezze del cavo di discesa espresse in m ammissibili in funzione della sezione Queste lunghezze sono vali...

Page 5: ...ne colleg sul quadro mot monofase Collegamenti errati nel mot trifase CONTINUI ATTACCHI E STACCHI Pressostato sonde di livello danneggiati Pompa sovradimensionata Temperatura liquido eccessiva Assorbi...

Page 6: ...TION Visually check the motor integrity in order to find possibile damages due to transportation Check power and voltage according to the application Manually check that the shaft can rotate Check the...

Page 7: ...he motor while moving it and do not lift the motor by the cable After mounting the pump check that the shaft is able to rotate and put some grease on the joint Choose the lead cable according to the t...

Page 8: ...able has to be suitable for submersible applications The table on page 14 table shows the maximum cable lengths expressed in m as function of the cross section These dimensions are valid for a tension...

Page 9: ...exchanged on ctrl panel single phase mot Wrong winding connections three phase mot FREQUENT STARTS AND STOPS Damaged pressure switch or level probe Oversized pump Too high liquid temperature Too high...

Page 10: ...ena y cierre mec nico Membrana de compensaci n INSPECCION PRELIMINAR Comprobar que el motor no haya sufrido da os durante el transporte Controlar que la potencia del motor y la tensi n sean adecuadas...

Page 11: ...e de alimentaci n rogamos ser cuidados manejando el motor para no da arlo y sobre todo recuerdamos de no mover el motor arrastrandolo por el cable Asemblar el motor con la bomba comprobando que el eje...

Page 12: ...eo para uso con motores sumergidos Las tablas en la pagina 14 indican las longitudes m ximas del cable de bajada en m permitidas en funcion de la secci n del cable Las siguientes son validas para una...

Page 13: ...on de las conexi nes en la caja motor monofas co Conexi nes incorrecyas en el motor trifas co ARRANQUES Y PAROS CONTINUOS Pres statos sonda de nivel da ados Bomba sobre dimensionada Temperatura excesi...

Page 14: ...39 187 243 6WPT 2500 25 18 5 39 61 84 116 157 204 6WPT 3000 30 22 54 74 103 140 182 MOTOR Hp kW SEZIONE CAVO CABLE CROSS SECTION SECCION DEL CABLE AWG 4x11 4x10 4x8 4x6 4x4 4x2 4x1 4x0 4x00 4x000 THRE...

Page 15: ...0 1 50 440 0 48 0 32 6WP 5000400 74 8 79 3 2860 0 89 83 0 1 50 6WP 5000415 73 0 77 4 2870 0 86 83 0 1 50 Technical data for 6WP series motors 50 Hz 50Hz Thrust Load Weight H kW Hp In Imax RPM Cos EFF...

Page 16: ...16 16...

Page 17: ...17 17...

Page 18: ...18 18...

Page 19: ...19 19...

Page 20: ...20...

Page 21: ..._________________________________________________________ _______________________________________________________________________________________ ______________________________________________________...

Page 22: ..._________________________________________________________ _______________________________________________________________________________________ ______________________________________________________...

Page 23: ......

Page 24: ...929 e mail mktgpl ebaraeurope com EBARA Pumps Europe S p A GERMANY Elisabeth Selbert Stra e 2 63110 Rodgau Germany Tel 49 0 6106 66099 0 Fax 49 0 6106 66099 45 e mail mktgd ebaraeurope com EBARA Pumps...

Reviews: