background image

 
 
 

PD120 OWNERS MANUAL 

Drawing No.  :-  TPC325 
Issue 

:-  11 

Date 

:-  07/09/18

 

 

SPECIFICATIONS 

    
    

 

 

 

M

M

M

M

ODEL

ODEL

ODEL

ODEL

::::    

Ebac PD120 

H

H

H

H

EIGHT

EIGHT

EIGHT

EIGHT

::::    

17.5” (445mm) 

W

W

W

W

IDTH

IDTH

IDTH

IDTH

::::    

27” (690mm) 

D

D

D

D

EPTH

EPTH

EPTH

EPTH

::::    

26” (660mm) 

W

W

W

W

EIGHT

EIGHT

EIGHT

EIGHT

::::    

176 lbs (80Kg) 

A

A

A

A

IRFLOW

IRFLOW

IRFLOW

IRFLOW

::::    

Low 261 CFM (445 M3/hr)  

High 491 CFM (835 M3/hr) 

P

P

P

P

OWER

OWER

OWER

OWER

::::    

1000 W 

P

P

P

P

OWER 

OWER 

OWER 

OWER 

S

S

S

S

UPPLY

UPPLY

UPPLY

UPPLY

::::    

110V–115V/60Hz/1ph 

F

F

F

F

INISH

INISH

INISH

INISH

::::    

Powder-coated Epoxy 

R

R

R

R

EFRIGERANT 

EFRIGERANT 

EFRIGERANT 

EFRIGERANT 

T

T

T

T

YPE

YPE

YPE

YPE

/Q

/Q

/Q

/Q

TY

TY

TY

TY

::::    

R407c 

Summary of Contents for PD120

Page 1: ...PC325 Issue 11 Date 07 09 18 EBAC MODEL PD120 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products Inc 700 Thimble Shoals Blvd Suite 109 Newport News VA 23606 2575 Tel 757 873 6800 Fax 757...

Page 2: ...1 Date 07 09 18 PD120 PD120 PD120 PD120 PACKAGE CONTENTS PACKAGE CONTENTS PACKAGE CONTENTS PACKAGE CONTENTS Item Description Quantity 1028200 Dehumidifier 1 3014338 PVC tube 12mm I D 3M 3086101 Jubile...

Page 3: ...ws the moist air through the cold evaporator coil which cools the air below its dew point Moisture forms on the evaporator coil and is collected in the condensate tray which is equipped with a permane...

Page 4: ...TH EPTH EPTH 26 660mm W W W WEIGHT EIGHT EIGHT EIGHT 176 lbs 80Kg A A A AIRFLOW IRFLOW IRFLOW IRFLOW Low 261 CFM 445 M3 hr High 491 CFM 835 M3 hr P P P POWER OWER OWER OWER 1000 W P P P POWER OWER OWE...

Page 5: ...e unit inlet and outlet must have a clearance of 0 5M from all adjacent surfaces and or structures Before connecting this unit to the relevant power supply the following must be carried out Selecting...

Page 6: ...running for 15 minutes E Observe the evaporator coils behind the filter on the air inlet end of the unit to confirm frost formation i If the air temperature is below 70 F an even coating of frost shou...

Page 7: ...the fins Alternatively vacuum clean the coils WARNING DO NOT STEAM CLEAN REFRIGERATION COILS 2 Check that the fan is firmly secured to the motor shaft and that the fan rotates freely The fan motor is...

Page 8: ...e of the refrigerant compressor The charging stub should be crimped and rebrazed after servicing NEVER allow permanent service valves to be fitted to any part of the circuit Service valves may leak ca...

Page 9: ...extraction 1 Insufficient air flow 2 Compressor fault 3 Loss of refrigerant gas 1 Check all of the above 2 Contact the Factory Service Center 3 Contact the Factory Service Center Unit vibrates excessi...

Page 10: ...S HOURS HOURS 80F 80F 80F 80F 60 60 60 60 RH RH RH RH 107 R R R REFRIGERANT EFRIGERANT EFRIGERANT EFRIGERANT 1600 Grams V V V VOLTAGE OLTAGE OLTAGE OLTAGE 115 Volts P P P POWER OWER OWER OWER 1 1 KW P...

Page 11: ...hazard This product contains fluorinated greenhouse gases covered by the Kyoto Protocol The refrigeration system is hermetically sealed The Global Warming Potential GWP of refrigerants used in product...

Reviews: