WARNINGS

  

 

 

This appliance can be used by children from 8 years and above and persons with 

reduced physical, sensory or mental capabilities or lack of experience and knowledge if 

they have been given supervision or instruction concerning use of the application in a 

safe way and understand the hazards involved. 

 

Children shall not play with the appliance. 

 

Cleaning and user maintenance shall not be made by children without supervision. 

 

If the SUPPLY CORD is damaged, it must be replaced by the manufacturer, its service 

agent or similarly qualified person in order to avoid hazard. 

 

This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. 

The refrigeration system is hermetically sealed. 

 

The Global Warming Potential (GWP) of refrigerants used in products manufactured by 

Ebac Industrial Products Ltd is as follows 

R134a – 1300 

R407c – 1610 

 

For type and weight of refrigerant contained in this unit, please refer to the product data 

label 

 

Due to the high pressures within the refrigeration circuit, under no circumstances must 

direct heat be applied to the evaporator coil in an attempt to remove the build-up of ice. 

 

No attempt should be made to cut open any part of the refrigeration circuit due to high 

pressures and gas involved. 

 

If the unit is switched off at the mains power supply for any reason, the unit must be 

allowed to stand at rest for at least three minutes before restarting. 

 

Summary of Contents for PD120

Page 1: ...PC325 Issue 11 Date 07 09 18 EBAC MODEL PD120 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products Inc 700 Thimble Shoals Blvd Suite 109 Newport News VA 23606 2575 Tel 757 873 6800 Fax 757...

Page 2: ...1 Date 07 09 18 PD120 PD120 PD120 PD120 PACKAGE CONTENTS PACKAGE CONTENTS PACKAGE CONTENTS PACKAGE CONTENTS Item Description Quantity 1028200 Dehumidifier 1 3014338 PVC tube 12mm I D 3M 3086101 Jubile...

Page 3: ...ws the moist air through the cold evaporator coil which cools the air below its dew point Moisture forms on the evaporator coil and is collected in the condensate tray which is equipped with a permane...

Page 4: ...TH EPTH EPTH 26 660mm W W W WEIGHT EIGHT EIGHT EIGHT 176 lbs 80Kg A A A AIRFLOW IRFLOW IRFLOW IRFLOW Low 261 CFM 445 M3 hr High 491 CFM 835 M3 hr P P P POWER OWER OWER OWER 1000 W P P P POWER OWER OWE...

Page 5: ...e unit inlet and outlet must have a clearance of 0 5M from all adjacent surfaces and or structures Before connecting this unit to the relevant power supply the following must be carried out Selecting...

Page 6: ...running for 15 minutes E Observe the evaporator coils behind the filter on the air inlet end of the unit to confirm frost formation i If the air temperature is below 70 F an even coating of frost shou...

Page 7: ...the fins Alternatively vacuum clean the coils WARNING DO NOT STEAM CLEAN REFRIGERATION COILS 2 Check that the fan is firmly secured to the motor shaft and that the fan rotates freely The fan motor is...

Page 8: ...e of the refrigerant compressor The charging stub should be crimped and rebrazed after servicing NEVER allow permanent service valves to be fitted to any part of the circuit Service valves may leak ca...

Page 9: ...extraction 1 Insufficient air flow 2 Compressor fault 3 Loss of refrigerant gas 1 Check all of the above 2 Contact the Factory Service Center 3 Contact the Factory Service Center Unit vibrates excessi...

Page 10: ...S HOURS HOURS 80F 80F 80F 80F 60 60 60 60 RH RH RH RH 107 R R R REFRIGERANT EFRIGERANT EFRIGERANT EFRIGERANT 1600 Grams V V V VOLTAGE OLTAGE OLTAGE OLTAGE 115 Volts P P P POWER OWER OWER OWER 1 1 KW P...

Page 11: ...hazard This product contains fluorinated greenhouse gases covered by the Kyoto Protocol The refrigeration system is hermetically sealed The Global Warming Potential GWP of refrigerants used in product...

Reviews: