REPAIRS 

1.

Should  an  electrical  component  fail,  consult  the  Factory  Service
Center to obtain the proper replacement part.

2.

If refrigerant gas is lost from the machine, it will be necessary to use
a  refrigeration  technician  to  correct  the  fault.    Contact  the  Factory
Service Center prior to initiating this action.

Any  competent  refrigeration  technician  will  be  able  to  service  the
equipment.  The following procedure must be used:

a. The source of the leak must be determined and corrected.

b. The  machine  should  be  thoroughly  evacuated  before

recharging.

c. The  unit  must  be  recharged  with  refrigerant  measured

accurately by weight.

d. For evacuation and recharging of the machine, use the crimped

and brazed charging stub attached to the side of the refrigerant
compressor.

The  charging  stub  should  be  crimped  and  rebrazed  after
servicing.  

N

EVER

 

allow permanent service valves to be fitted to

any part of the circuit.  Service valves may leak causing further
loss of refrigerant gas.

3.

The  refrigerant  compressor  fitted  to  the  dehumidifier  is  a  durable
unit that should give many years of service.  Compressor failure can
result from the machine losing its refrigerant gas.  The compressor
can be replaced by a competent refrigeration technician.

Failure  of  the  compressor  can  be  confirmed  by  the  following
procedure:

a. Establish  that  power  is  present  at  the  compressor  terminals

using a voltmeter.

b. With the power disconnected, check the continuity of the internal

winding  by  using  meter  across  the  compressor  terminals.    An
open circuit indicates that the compressor should be replaced.

c. Check that the compressor is not grounded by establishing that

a  circuit  does  not  exist  between  the  compressor  terminals  and
the shell of the compressor.

E B A C    K O M P A C T    R E S T O R A T I O N    D E H U M I D I F I E R 

Pure n Natural Systems  |  purennatural.com  |  1-800-237-9199

Summary of Contents for KOMPACT

Page 1: ...9 Drawing TPC303 Issue 7 Date 03 10 12 KOMPACT INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL E B A C K O M P A C T R E S T O R A T I O N D E H U M I D I F I E R Pure n Natural Systems purennatural com 1 800...

Page 2: ...ONTENTS Item Description Quantity 10240KP US Dehumidifier 1 3086144 Quick release hose coupling 1 3944110 PVC Tube 3 8 I D 7 8M TPC303 Manual 1 E B A C K O M P A C T R E S T O R A T I O N D E H U M I...

Page 3: ...asses through the hot condenser coil where it is reheated using the same energy removed during the cooling phase plus the additional heat generated by the compressor The air is therefore discharged fr...

Page 4: ...ial Products Ltd is as follows R134a 1300 R407c 1610 For type and weight of refrigerant contained in this unit please refer to the product data label MODEL 10240KP US HEIGHT 24 610mm WIDTH 20 508mm DE...

Page 5: ...ve 78 F frost and or droplets of condensed water should cover the entire evaporator coil F After continuous running time of approximately 55 minutes unit will enter Hot Gas defrost mode for several mi...

Page 6: ...rost Partial frosting accompanied by frosting of the thin capillary tubes indicates loss of refrigerant gas or low charge During this inspection check visually to ensure that the pump rollers are turn...

Page 7: ...and rebrazed after servicing NEVER allow permanent service valves to be fitted to any part of the circuit Service valves may leak causing further loss of refrigerant gas 3 The refrigerant compressor f...

Page 8: ...3 Loss of refrigerant gas 1 Check all of the above 2 Contact the Factory Service Center 3 Contact the Factory Service Center Little or no defrost when required 1 Faulty timer 2 Faulty by pass valve 1...

Page 9: ...1107 1 6 Capillary Tube 3014251 48 7 Solenoid Valve 3020814 1 8 Filter Dryer 3020901 1 9 Compressor 3022169 1 10 Solenoid Coil 3030421 1 11 Capacitor 3030908 1 12 Terminal Block 3031460 1 13 Fan Motor...