Drawing   : - TPC303 
Issue 

: - 7 

Date 

: - 03/10/12 

SPECIFICATIONS 

"This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. The 

refrigeration system is hermetically sealed. 

The Global Warming Potential (GWP) of refrigerants used in products manufactured by Ebac 

Industrial Products Ltd is as follows 

R134a – 1300 

R407c – 1610 

For type and weight of refrigerant contained in this unit, please refer to the product data label"

 

M

ODEL

:

 

10240KP-US 

H

EIGHT

:

 

24” (610mm) 

W

IDTH

:

 

20” (508mm) 

D

EPTH

:

 

19” (483mm) 

W

EIGHT

:

 

78 lbs (35 Kg) 

A

IRFLOW

:

 

360 CFM (608 M3/hr) 

P

OWER 

S

UPPLY

:

 

110V/ 60Hz/ 1 ph 

F

INISH

:

 

Powder-coated Epoxy 

O

PERATING 

R

ANGE

:

 

33°F – 95°F 

R

EFRIGERANT

:

 

R-407c (13 oz)

E B A C    K O M P A C T    R E S T O R A T I O N    D E H U M I D I F I E R 

Pure n Natural Systems  |  purennatural.com  |  1-800-237-9199

Summary of Contents for KOMPACT

Page 1: ...9 Drawing TPC303 Issue 7 Date 03 10 12 KOMPACT INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL E B A C K O M P A C T R E S T O R A T I O N D E H U M I D I F I E R Pure n Natural Systems purennatural com 1 800...

Page 2: ...ONTENTS Item Description Quantity 10240KP US Dehumidifier 1 3086144 Quick release hose coupling 1 3944110 PVC Tube 3 8 I D 7 8M TPC303 Manual 1 E B A C K O M P A C T R E S T O R A T I O N D E H U M I...

Page 3: ...asses through the hot condenser coil where it is reheated using the same energy removed during the cooling phase plus the additional heat generated by the compressor The air is therefore discharged fr...

Page 4: ...ial Products Ltd is as follows R134a 1300 R407c 1610 For type and weight of refrigerant contained in this unit please refer to the product data label MODEL 10240KP US HEIGHT 24 610mm WIDTH 20 508mm DE...

Page 5: ...ve 78 F frost and or droplets of condensed water should cover the entire evaporator coil F After continuous running time of approximately 55 minutes unit will enter Hot Gas defrost mode for several mi...

Page 6: ...rost Partial frosting accompanied by frosting of the thin capillary tubes indicates loss of refrigerant gas or low charge During this inspection check visually to ensure that the pump rollers are turn...

Page 7: ...and rebrazed after servicing NEVER allow permanent service valves to be fitted to any part of the circuit Service valves may leak causing further loss of refrigerant gas 3 The refrigerant compressor f...

Page 8: ...3 Loss of refrigerant gas 1 Check all of the above 2 Contact the Factory Service Center 3 Contact the Factory Service Center Little or no defrost when required 1 Faulty timer 2 Faulty by pass valve 1...

Page 9: ...1107 1 6 Capillary Tube 3014251 48 7 Solenoid Valve 3020814 1 8 Filter Dryer 3020901 1 9 Compressor 3022169 1 10 Solenoid Coil 3030421 1 11 Capacitor 3030908 1 12 Terminal Block 3031460 1 13 Fan Motor...