4.2
Description of the electrical connections
230 Vac Neutral
1
230 Vac Power supply 50 Hz NEUTRAL
Ground
2
Ground connection
230 Vac Phase
3
230 Vac Power supply 50 Hz PHASE
Signal light
4
Outputs for LAMP (flashing light electronic card) or 230 Vac
COURTESY LIGHT, maximum power of the lamp 40 or 100W
5
M 1 Com
6
Output for motor connection 1 COMMON pole
M 1 Open
7
Output for motor connection 1 pole OPEN
M 1 Close
8
Output for motor connection 1 pole CLOSE
M 2 Com
9
Output for motor connection 2 COMMON pole
M 2 Open
10
Output for motor connection 1 pole OPEN
M 2 Close
11
Output for motor connection 1 pole CLOSE
LSC M2
12
Input Closing Limit Switches motor no.2
LSO M2
13
Input Opening Limit Switches motor no. 2
LSC M1
14
Input Closing Limit Switches motor no. 1
LSO M1
15
Input Opening Limit Switches motor no. 1
Photocell A
16
Input photocell A; working only by closing (see chapter 2.3)
START
17
Input command bi-stable START
24Vac
18
Output for 24Vac
24Vac / 12Vac
19
Output for electrical lock 12Vac 50Hz 1A
12Vac Serrat.
20
Output for electrical lock 12Vac 50Hz 1A
STOP
21
STOP input
PEDESTRIAN
22
Input for bi-stable function partial opening PEDESTRIAN
Photocell B
23
Input photocell B working in closing and in opening (see chap. 2.3)
Common 1
-
24
Common for all inputs:
services, Security devices, coaxial antenna cable sock.
A
25
Input for antenna (antenna cable)
Light
26
Contact for light (for flashing light without electronic card)
Light
27
Contact for light (for flashing light without electronic card)
PhotoTEST
28
Output 24Vac TEST (see chapter 6)
12Vac
29
Output 12Vac
24Vdc +
30
Output 24Vdc +
Common
24Vdc -
31
Output 24Vdc -
Common for inputs: services and safety
START-S4XL
Technical manual