4
UX8800 INSTALLATION
4 . 1
P h y s i c a l I n s t a l l a t i o n
CAUTION:
The UX8800’s operating temperature range is 32 F to 104 F degrees / 0 C to 40
C degrees. The UX8800 may not function properly in temperatures below this range and may
be damaged in temperatures above this range.
4.1.1
MOU
N
TI
N
G
The UX8800 is designed to mount in a standard, 19 in equipment rack occupying one EIA rack space (1.75
in). When rack mounting, use screws with mating plastic washers to help protect the finish of the UX8800.
The UX8800 weighs approximately 10 lb / 4.5 kg.
4.1.2
V
E
N
TILATIO
N
An integral fan is used to properly ventilate the
UX8800. The fan is located to the rear of the left
side of the chassis. The air intake grilles are located
on the right side and on top of the chassis. Maintain
clearances around the left and right sides of the
chassis as shown in the drawing.
It is recommended to leave one empty rack space
above the UX8800 to provide 1.75 in / 45 mm
clearance above the top air intake holes for
additional ventilation.
4 . 2
A C M a i n s C o n n e c t i o n s
4.2.1
AC MAI
N
S
V
OLTAGE
The UX8800 has a universal, auto-ranging power supply that operates from 100 V to 240 V, 50 Hz to 60 Hz.
The UX8800 is compatible with these nominal ac mains:
100 V, 110 V, 115 V, 120 V, 127 V, 220 V, 230 V, and 240 V at 50 Hz to 60 Hz.
CAUTION:
To maintain compliance ratings, keep the ac mains voltage between
100 V to 240 V.
4.2.2
IEC POWER CORD RECEPTACLE
An IEC-320 ac mains inlet on the rear panel accepts the detachable power cords supplied with the unit. Use
the power cord appropriate for these nominal ac mains supply voltages.
120 V ac mains: use the power cord with the NEMA 5-15 plug, EAW part # 640-01-00
220 V ac mains: use the power cord with the Schuko plug, EAW part # 640-02-02
CAUTION:
It is the user’s responsibility to provide a proper ac mains plug for any
ac mains outlet configuration that differs from those supplied with the product.
4.2.3
GROU
N
DI
N
G
The chassis of this product is grounded through the grounding conductor of the power cord. To avoid
electric shock, plug the power cord into a properly wired and grounded receptacle before making any
connections to or operating the product.
DANGER:
This equipment must be operated with the power cord grounding conductor
connected to a properly grounded ac outlet. Do not disconnect, “lift,” or otherwise remove this
ground connection. Without this connection, accessible parts, including knobs and controls
that may appear to be insulated, can render an electric shock that can cause injury or death to
operating personnel.
Page 5
MAINTAIN 1 in / 25 mm
CLEARANCE AROUND
SIDE AIR INTAKE GRILLES
RECOMMENDED:
MAINTAIN 1-3/4 in / 45 mm CLEARANCE
ABOVE TOP AIR INTAKE GRILLES
MAINTAIN 2 in / 50 mm
CLEARANCE AROUND
FAN EXHAUST GRILLE
AIR FLOW
VENTILATION CLEARANCES
POWER
~100-240 VAC
50-60Hz 75W