15
Operating Indicators
Please refer to the chart below to determine the current operating status based on the three LED indicators
located on the rear-input panel of your RS unit.
Indication
Condition
Next Steps
LED
Color/Repeat
Period
Status LED
Green - Solid
All
components
working
properly
None
Signal LED
Green -
Flashing/Solid
An input
signal is being
received by
the amplifier.
None
Limiter LED
Red - Flashing The speaker is
soft limiting.
None
Red - Solid
The speaker is
clipping.
Reduce volume until
the limit light only
flashes occasionally.
ALL LEDs
Flashing
System Fault
Contact EAW
Support.
Limit
The limiting parameters set in RS Products are engineered to provide a high level of protection for the drivers
while maximizing sonic performance and output. The
Limit
indicator in the rear input panel illuminates when
limiting is occurring. If this is flashing occasionally, meaning no more than once every 3 seconds or so, then
levels are probably OK, but at maximum if this indicator is flashing more than once every 3 seconds or so,
reduce the input signal level.
CAUTION
:
Electronic limiters cannot provide absolute protection against driver failure. Thus, if limiting is occurring,
it is a warning that excessive signal levels are being approached. EAW is not responsible for damaged or broken
speaker components due to user error.
Operating Limits
The RS products
have a Limiter indicator. The speaker is designed to maximize performance and clarity at
limit – if the limit light is blinking every few seconds, no action is needed. If the limit light is flashing more
frequently, or is continuously on, reduce the volume to avoid distortion.