2.3.4  Infrared light setting

This product can provide distinct images in environment with 

illuminance less than 0.5LUX, the user can select the illuminance 

of the infrared light according to the environment.
This operation can achieved by S2 in the infrared light cylinder.

Infrared light control module

On/off the 

illuminance 

setting of 

the infrared 

light

S2

Figure 2.3.4.1. Connection of the camera and control meth-

od setting

Figure 2. Figure 2.3.5.1 Infrared light control switch

The switch ON and OFF of every digit in the infrared light control 

switch is in correspondence with power on and power off of the 

corresponding illuminance switch. The infrared light start to work 

when the environment illuminance is lower than the set value of 

the swith; it will stop work when the environment illuminance is 

better than the set value.
The default setting is the 3

rd

 digit is set on. Only one digit in S2 

can be set at on and the others must be off. Restart or remotely 

reboot is required for the changed setting.

Table 3.2.5.2.  Definition of S2

DIP

START-UP (LUX)

SHUT-DOWN (LUX)

1

0.5

4

2

1.5

8

3

5 (Default)

20

4

10

50

5

15

75

6

20

100

7

OFF

OFF

8

OFF

OFF

2.3.5  Inspection and examination before service

Check if the power supply, AB control cable and video cable are 

well connected and if the settings on the switch are correct.

2.3.6  Service status and inspection in service

YHPTZ41 will start self checking automatically after power on.

• 

Normal self checking procedures:

Rain wiper 

run once

Horizontal left rotating a round→right 

rotating a round

Vertical rotating to-90°→up to +90°→back 

to horizontal position

2.3.7  Screen OSD display and menu setting

YHPTZ41 possess a perfect Chinese and English menu system: 

via 95# preset position to callout the menu when the product is 

stand by, the 

up, down, left

 and 

right

 button on the PTZ, also the 

open

 and 

close

 button on the iris become control keys. At this 

time, command of the other keys are invalid, all settings in the 

menu can be saved when power cut off suddenly.

2.3.8  Camera setting, IE browser and client software setting

See document provided by the manufacturer of the camera.

2.4  Support preparation before installation of YHPTZ41

2.4.1  Support type installation

Select suitable position for installation hole, adopt expansion 

anchors to fix the support. The Ex junction box shall be installed in 

a place convenient for installation and maintenance. Laying down 

the cable from the slot or tray to the junction box. 
See 2.4.1.2 for the support specifications.

Install support

Slot or tray

Ex junction box

wall

Figure 2.4.1.1 Support installation and wire connection

Summary of Contents for YHPTZ41 Series

Page 1: ...grated Camera Set IP Code IP 68 1 2m 45min Ex Marking II2G Ex db op is IIC T6 Gb for type YHPTZ41 or Ex db IIC T6 Gb for type YPTZ41 1 II2D Ex tb IIIC T80 C Db Ex tb op pr IIIC T95 C Db optical fiber...

Page 2: ...ssion of Cooper Yuhua Cooper Yuhua remains the right to modify the content and technical specifications of the product in this Instruction Manual without any form of notification in order to provide t...

Page 3: ...per operation that against the Instruction Manual Damage caused by unauthorized disassembly Thunder or other force majeure natural disasters If any other contracts between clients and us exist we will...

Page 4: ...midity specified in Chapter 1 6 To be sure the power supply comply with the requirement indicated in the nameplate The internal and external grounding shall be reliable Ensure the installation is firm...

Page 5: ...rd atmospheric pressure 9 2 0 Installation debugging 10 2 1 Cautions 10 2 2 Assembly 11 2 3 Usage 12 2 4 Support preparation before installation of YHPTZ41 14 2 5 Installation and fastening 15 2 6 Pro...

Page 6: ...Avoid damage caused by compressing or violent vibration in transmission storage or operation The product shall be well packaged as new product or equivalent in transmission We suggest using this produ...

Page 7: ...an 80 C in normal operation Toughed glass is adopted in observation port it has passed the impact and thermal shock test IP68 1 2m 45min Stuffing box type cable entries are adopted in this product the...

Page 8: ...rt 28 Protection of equipment and transmission systems using optical radiation It is used in the places where is classified as Zone 1 and Zone 2 contained Group IIA Group IIB and Group IIC gases tempe...

Page 9: ...cal data Material stainless steel 304 or 316L Horizontal rotating range CC 0 360 continues Vertical rotating range 90 90 Horizontal rotating speed 0 1 40 S Smooth variable speed rotation Vertical rota...

Page 10: ...shade 2pcs Certificate of conformity Qualification certificate and Instruction Manual Cross recess oval head screws M5X8 4pcs Hexagon bolts M8X30 6pcs Brass screws 1 4 X6 1pc Brass screws 1 4 X12 1pc...

Page 11: ...lease follow the Instruction b The power must comply with requirements specified in 5 c Please use this product in conditions atmosphere pressure temperature and humidity specified in chapter 1 6 d Si...

Page 12: ...em Digital video signal is transmitted by wired or wireless IP networks The video can be monitored and recorded at any time no matter in LAN or WAN such as internet 2 3 2 Cable indication A composite...

Page 13: ...ch SW1 Protocol setting PELCO P PELCO D VICON protocols can be used PELCO P and PELCO D protocol can be set directly by SW1 For VICON protocol the following instructions shall be followed turn on the...

Page 14: ...examination before service Check if the power supply AB control cable and video cable are well connected and if the settings on the switch are correct 2 3 6 Service status and inspection in service YH...

Page 15: ...n the basis of values specified in tables 2 of EN IEC 60079 1 2 7 Grounding Internal and external grounding shall be well connected and reliable 2 8 Reserved cable The length of cable reserved on fini...

Page 16: ...can be delivered in all modes of transportation but without direct rain or snow 4 2 Storage condition duration and cautions This product can be stored for one year in environment of temperature range...

Page 17: ...us harmful substances or elements in the component homogeneous material is lower than the limit specified in the standard 2 Symbol means the content of the poisonous harmful substances or elements in...

Page 18: ...t warrant a specific layout or functionality Their use in whatever form is subject to prior approval by Eaton The same applies to Trademarks especially Eaton Moeller and Cutler Hammer The Terms and Co...

Reviews: