Cautions before installation and in service

Check the following items before installation: 

a.  Check if there is a certificate of conformity number
b.  Check if the application area indicated in the Ex making is 

suitable for the intend location

c.  Check if there is any crack or other defect that may 

damage the Ex performance

d.  Check if there are internal and external grounding

Cautions in service:

a.  It’s not suggested for users to dismantle this product at 

will, please follow the Instruction.

b.  The power must comply with requirements specified in 5.
c.  Please use this product in conditions (atmosphere pressure, 

temperature and humidity) specified in chapter 1.6.

d.  Since Ex product is very special, debugging with power 

before installation if available.

e.  DO NOT OPEN WHEN ENERGIZED!
f.  The yield stress of the fastener elements of each part 

of the flame proof enclosure must be at least equal to 

700 N/mm

2

.

2.2  Assembly 
2.2.1  Component assembling

Fixing bolts of the sun shade: Cross 

recess oval head screws: 4-M5X8

Figure 2.2.1.1 installation of sun shade

Caution: tighten the 

compression nuts with 

wrench after the cable or 

flexible pipe are installed.

Figure 2.2.1.2  Tighten the compression nuts

Summary of Contents for YHPTZ41 Series

Page 1: ...grated Camera Set IP Code IP 68 1 2m 45min Ex Marking II2G Ex db op is IIC T6 Gb for type YHPTZ41 or Ex db IIC T6 Gb for type YPTZ41 1 II2D Ex tb IIIC T80 C Db Ex tb op pr IIIC T95 C Db optical fiber...

Page 2: ...ssion of Cooper Yuhua Cooper Yuhua remains the right to modify the content and technical specifications of the product in this Instruction Manual without any form of notification in order to provide t...

Page 3: ...per operation that against the Instruction Manual Damage caused by unauthorized disassembly Thunder or other force majeure natural disasters If any other contracts between clients and us exist we will...

Page 4: ...midity specified in Chapter 1 6 To be sure the power supply comply with the requirement indicated in the nameplate The internal and external grounding shall be reliable Ensure the installation is firm...

Page 5: ...rd atmospheric pressure 9 2 0 Installation debugging 10 2 1 Cautions 10 2 2 Assembly 11 2 3 Usage 12 2 4 Support preparation before installation of YHPTZ41 14 2 5 Installation and fastening 15 2 6 Pro...

Page 6: ...Avoid damage caused by compressing or violent vibration in transmission storage or operation The product shall be well packaged as new product or equivalent in transmission We suggest using this produ...

Page 7: ...an 80 C in normal operation Toughed glass is adopted in observation port it has passed the impact and thermal shock test IP68 1 2m 45min Stuffing box type cable entries are adopted in this product the...

Page 8: ...rt 28 Protection of equipment and transmission systems using optical radiation It is used in the places where is classified as Zone 1 and Zone 2 contained Group IIA Group IIB and Group IIC gases tempe...

Page 9: ...cal data Material stainless steel 304 or 316L Horizontal rotating range CC 0 360 continues Vertical rotating range 90 90 Horizontal rotating speed 0 1 40 S Smooth variable speed rotation Vertical rota...

Page 10: ...shade 2pcs Certificate of conformity Qualification certificate and Instruction Manual Cross recess oval head screws M5X8 4pcs Hexagon bolts M8X30 6pcs Brass screws 1 4 X6 1pc Brass screws 1 4 X12 1pc...

Page 11: ...lease follow the Instruction b The power must comply with requirements specified in 5 c Please use this product in conditions atmosphere pressure temperature and humidity specified in chapter 1 6 d Si...

Page 12: ...em Digital video signal is transmitted by wired or wireless IP networks The video can be monitored and recorded at any time no matter in LAN or WAN such as internet 2 3 2 Cable indication A composite...

Page 13: ...ch SW1 Protocol setting PELCO P PELCO D VICON protocols can be used PELCO P and PELCO D protocol can be set directly by SW1 For VICON protocol the following instructions shall be followed turn on the...

Page 14: ...examination before service Check if the power supply AB control cable and video cable are well connected and if the settings on the switch are correct 2 3 6 Service status and inspection in service YH...

Page 15: ...n the basis of values specified in tables 2 of EN IEC 60079 1 2 7 Grounding Internal and external grounding shall be well connected and reliable 2 8 Reserved cable The length of cable reserved on fini...

Page 16: ...can be delivered in all modes of transportation but without direct rain or snow 4 2 Storage condition duration and cautions This product can be stored for one year in environment of temperature range...

Page 17: ...us harmful substances or elements in the component homogeneous material is lower than the limit specified in the standard 2 Symbol means the content of the poisonous harmful substances or elements in...

Page 18: ...t warrant a specific layout or functionality Their use in whatever form is subject to prior approval by Eaton The same applies to Trademarks especially Eaton Moeller and Cutler Hammer The Terms and Co...

Reviews: