6
XFG1 HD IP Fixed Optical Camera Station
XFG1 HD IP OPtIcal FIXeD camera
TMOX001.A September 2021 www.eaton.com
247
82
4x 8.5
MTG HOLES
= 97 =
53
10
= 73 =
= 119 =
8.3
6.2
Fig.2
Wall mounting bracket
The XFG1 is supplied with a tilt-swivel bracket (fig.1), which
is fitted as standard to the camera. Also, the wall mounting
bracket, (fig.2) supplied separately in the packaging, is to be
installed in the desired location before attaching the XFG1 &
tilt-swivel assembly.
4.0 ELECTRICAL INSTALLATION
Electrical installation and servicing should only be carried
out by qualified service personnel and in accordance with all
local/national codes of practice and standards e.g. EN 60079-
14:2014 and IEC 60079-14:2013.
Due to the large number of possible configurations, this
manual only covers the standard installation of the units.
For detailed connection and configuration of units, the installer
should refer to individual project specific drawings and
information.
Units can be supplied, as required, with either AC or DC 24V,
or 220VAC Supply; all ±10% The units should only be powered
from the specified voltage, no allowance is made for varying
voltage supply. Units may also work with Power Over Ethernet
(POE) 12V,24v,48v & 56V DC
Warning:
irreparable damage to the unit will
result from an incorrect power supply voltage
For safe access to electrical connections with the camera,
refer to ATEX controlled certified ANNEX to this manual.