3
Xenon beacon Xb11
TM135 February 2023 www.eaton.com
Xenon beacon XB11
English
The IECEx certificate and product label carry the IECEx
equipment protection level marking.
Gb
Db
Where Gb signifies suitability for use in a Zone 1 surface
industries area in the presence of gas.
Where Db signifies suitability for use in a Zone 21 surface
industries area in the presence of dust.
ATEX units
Certified to: EN60079-0, EN60079-1 and EN60079-31
Ex d unit (ATEX certification No. BAS99ATEX2195)
Ex d IIB Tx (Tamb.) Gb
Ex tb IIIC Tx (Tamb.) Db IP66/IP67
Gas T-rating (Tx)
Dust T-rating (Tx)
ambient temp
range (Tamb.)
T4
T105°C
(-55°C to +70°C)
T5
T90°C
(-55°C to +55°C)
T6
T75°C
(-55°C to +40°C)
The ATEX certificate and product label carry the ATEX
group and category marking:
II 2 GD
Where:
Signifies compliance with ATEX
II
Signifies suitability for use in surface industries
2
Signifies suitability for use in a zone 1 area
G Signifies suitability for use in the presence of gases
D Signifies suitability for use in the presence of dust
The ATEX certificate and product label also carry the
following mark:
1180
This signifies unit compliance to the relevant European
directives, in this case 94/9/EC, along with the number
of the notified body issuing the EC type examination
certificate.
The ATEX and IECEx units also have the following EMC
approvals
Conducted Emissions (DC) to EN61000-6-3:2007
Radiated Field Immunity (DC and AC) to
EN61000-6-2:2005/IEC61000-4-3:2002
Electrical Fast Transients/Bursts (DC and AC) to
EN61000-6-2:2005/IEC61000-4-4:2004
Surge Immunity (DC and AC) to EN61000-6-2:2005/
IEC61000-4-5:1995 + A1:2000
Dips and Interruptions (AC) to EN61000-6-2:2005/
IEC61000-4-11:2004