background image

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

North America 

— HQ 

70 Wood Ave., South, 2nd Floor 
Iselin, NJ 08830 
Toll Free: (800) 656-3344 
(North America Only) 
Voice: (732) 767-4200 
 
 

China 

No. 3, Lane 280, Linhong Road 
Changning District, 200335 
Shanghai, P.R. China 
Voice: +86-21-5200-0099 
 
 

Singapore 

4 Loyang Lane #04-01/02 
Singapore 508914 
Voice: +65-6825-1668

 

Europe/Africa/Middle East 

Friedensstraße 41 
D-68804 Altlussheim, Germany 
Voice: +49-6205-2094-0 
 
Auf der Heide 2 
53947 Nettersheim, Germany 
Voice: +49-2486-809-0 
 
An den Nahewiesen 24 
55450 Langenlonsheim, Germany 
Voice: +49 6704 204-0 
 
 

Brazil 

Av. Julia Gaioli, 474 

– 

Bonsucesso 
07251-500 

– Guarulhos, Brazil 

Voice: +55 (11) 2465-8822

 

For more information, please e-mail us at 
[email protected] 
 
Visit us online eaton.com/filtration for a complete 
list of Eaton´s filtration products. 
 

©2012 Eaton Corporation. All Rights Reserved. 
All trademarks and registered trademarks are the property of their respective 
owners. Litho USA.

 

 

All information and recommendations appearing in this brochure concerning the 
use of products described herein are based on tests believed to be reliable. 
However, it is the user’s responsibility to determine the suitability for his own use 
of such products. Since the actual use by others is beyond our control, no 
guarantee, expressed or implied, is made by Eaton as to the effects of such use or 
the results to be obtained. Eaton assumes no liability arising out of the use by 
others of such products. Nor is the information herein to be construed as 
absolutely complete, since additional information may be necessary or desirable 
when particular or exceptional conditions or circumstances exist or because of 
applicable laws or government regulations.

 

 
 

Summary of Contents for WSPS 05

Page 1: ...WSPS 05 Online sensor for water in oil diagnostics Instruction manual Version 1 6 Serial no Version valid from 25 11 2015 ...

Page 2: ...ng principle 4 2 1 Sensor installation 5 2 2 Evaluating measurements 5 3 MAINTENANCE 6 3 1 Sensor cleaning 6 4 CALIBRATION 6 4 1 Water saturation 6 4 2 Integrated temperature sensor 6 5 APPENDIX 7 5 1 Technical Data 7 5 2 Dimensions 7 5 3 Pin assignment 8 5 4 Sensor characteristic 8 5 5 Application areas compatibility 9 5 6 Trouble shooting 9 5 7 Shipment 9 ...

Page 3: ...nstructions which guarantee safe handling and support your devices unobjectionable condition Therefore it is a necessity for all people who operate install or maintain this device to mind this manual 1 2 Conventional use With this WSPS 05 you have purchased an effective diagnostic system for the saturation level of water in oil It operates very reliable and meets the requirements of daily use The ...

Page 4: ...ectric for interelectrode capacitance This foil is capable of absorbing water molecules due to its microporous structure This absorption causes a change in capacity of this element which is converted into the output signal between 4 and 20 mA Measurements are the water saturation of the fluid in percent which is direct proportional to the output signal of the sensor see also the characteristic of ...

Page 5: ...o the WSPS 05 by using the plug The sensor is now ready for operation 2 2 Evaluating measurements Green range 0 70 saturation The presence of free water is unlikely The water solved in the oil is not a threat Yellow range 70 90 saturation The presence of free water in small amounts is probable Additional measurements and actions to reduce the water content are suggested Red range 90 100 saturation...

Page 6: ...calibrated based on defined salt solutions It is recommended to carry out an annual examination of the calibration by comparison with a hygrometer in air In case of variations 5 the sensor is to be sent to the manufacturer for a new calibration 4 2 Integrated temperature sensor Upon delivery of the WSPS 05 the integrated temperature sensor is calibrated An annual examination of the calibration at ...

Page 7: ...pressure 0 25 bar 0 362 5 psi Flow velocity 2 m s 6 6 ft s Ambient temperature 25 85 C 13 F 185 F Temperature range of fluid 40 90 C 40 F 194 F temporary 100 C 212 F Survival temperature 90 C 194 F Storage temperature 40 100 C 40 F 212 F Power supply 12 30 VDC Analogue outputs 2 x 4 20 mA Protection class IP 65 Screw thread G Ohmic resistance 5 2 Dimensions ...

Page 8: ... 4 20 mA Saturation Pin 3 12 30 V DC Pin 4 Output 4 20 mA Temperature Cable color Connection cable 1 brown 12 30 V DC 2 white 4 20 mA Saturation 3 blue 12 30 V DC 4 black 4 20 mA Temperature 5 4 Sensor characteristic 1 4 3 2 1 2 3 4 mA 12 30 V DC 0 V DC 1 3 WSPS 05 2 4 ...

Page 9: ...cleaning the sensor and checking cables for brakes Any other case requires sending in the WSPS 05 sensor to Eaton Technology GmbH Altlussheim branch in order to recover the functions A brief description of the problem would expedite the trouble shooting and the repair process To check your warranty or to answer questions by phone we need the serial number and the date of purchase of the instrument...

Page 10: ...e list of Eaton s filtration products 2012 Eaton Corporation All Rights Reserved All trademarks and registered trademarks are the property of their respective owners Litho USA All information and recommendations appearing in this brochure concerning the use of products described herein are based on tests believed to be reliable However it is the user s responsibility to determine the suitability f...

Reviews: