![Eaton VICKERS DG3V-10 A Series Overhaul Manual Download Page 28](http://html1.mh-extra.com/html/eaton/vickers-dg3v-10-a-series/vickers-dg3v-10-a-series_overhaul-manual_525218028.webp)
28
DG4S4-01*B/C-(U)-*-60
2
7
9
21
11
5
12
10
1
3
4
6
16
27
17
15
19
18
8
22
23
20
13
14
26
28
29
24
25
Item
Nomenclature
Quantity
Item
Nomenclature
Quantity
1
Screw
4
16
Stop
2
2
Name Plate
1
17
Spring
2
3
Gasket & Wire S/A
1
18
Push Pin
2
4
Screw
1
19
‘‘O’’ Ring
2
5
Body
1
20
Core Tube S/A
1
6
Rivet
4
21
Spool
1
7
Diagram Plate
1
22
Plug
1
8
Knob
2
23
‘‘O’’ Ring
1
9
‘‘O’’ Ring
2
24
Plug
1
10
Coil (Type A)
2
25
Plug
1
11
DIN Coil
2
26
‘‘O’’ Ring
1
12
Plug
2
27
Plug
1
13
DIN Receptacle
2
28
‘‘O’’ Ring
1
14
Gasket
2
29
‘‘O’’ Ring
5
15
Washer
2
Figure 19. Wet Armature Pilot Valve, DG4S4-01*B/C-(U)-*-60
Section IX - Start-Up and Test
A. Start-Up
Start the system and sequence the unit through all positions
while watching for appropriate movement of actuators.
Improper or erratic movement of the actuators may indicate
incorrect assembly of the unit or presence of trapped air.