7.1  GENERAL

In order to minimize production downtime, it is recommended that 

an adequate quantity of spare parts carried in stock. The quantity 

will vary from customer to customer, depending upon the service 

severity and continuity requirements. Each customer should develop 

his own level based on operating experience.

7.1.1 ORDERING INSTRUCTIONS

1.  Always specify the selectable ground and test device rating 

information and general order number, from the nameplate.
2.  Describe the item, give the style number, and specify the 

quantity required.
3.  Specify the method of shipping desired.
4.  Send all orders or correspondence to the nearest Eaton’s 

Electrical Services & Systems sales office.
5.  Include negotiation number with order when applicable.

Table 5.  Common Replacement Parts

ITEMS

DESCRIPTIONS

CURRENT 

EATON STYLE 

NUMBER

DISCONNECTS

Primary 

Disconnects

1200 / 2000 Primary Disconnect Assembly

94B8000G98

3000 Primary Disconnect Assembly

94B8000G99

Summary of Contents for VCP-W Series

Page 1: ...Instruction Book IB182312EN 50 75 150 VCP W Selectable Ground and Test Device 150 VCP W SGT June 2016 Supersedes October 2015 Effective...

Page 2: ...an Eaton sales office should be consulted Sale of the product shown in this literature is subject to the terms and conditions outlined in appropriate Eaton selling policies or other contractual agree...

Page 3: ...4 2 BUSHINGS AND DISCONNECTING CONTACT ASSEMBLIES 11 4 3 GROUNDING CONTACTS 11 4 4 BREAKER CELL CODING PLATES 11 4 5 CELL POSITION DESCRIPTION 11 4 6 DEVICE AMPERAGE CONVERSION PROCEDURE 13 SECTION 5...

Page 4: ...N AND VAST VARIETY OF SYSTEM USER REQUIREMENTS SPECIFIC SAFE OPERATING PROCEDURES FOR THE USE OF THIS DEVICE MUST BE DEVELOPED BY THE USER WARNING SATISFACTORY PERFORMANCE OF SELECTABLE GROUND AND TES...

Page 5: ...able Ground and Test Device Dimensions Breaker Type Sized For Circuit Breaker Compartment Amps A B C D E F G H I J K 150 VCP W 500 Dual 1200 2000 28 50 26 76 10 00 27 81 12 00 14 13 20 88 24 63 2 25 2...

Page 6: ...n the device Failure to do so could result in electrical shock leading to death severe personnel injury or property damage Do not leave the selectable ground and test device in an intermediate positio...

Page 7: ...Services System office Tools and Accessories Racking Handle The racking handle is used to drive the racking mechanism which moves the SG T device into and out of the cell This racking handle is the s...

Page 8: ...g objects excessive moisture etc must be provided Container should be arranged to permit free circulation of air on all sides and temporary heaters should be used to minimize condensation Moisture can...

Page 9: ...ront External View of 150 VCP W SG T Device 3 2 1 8 5 4 7 6 Front External View 150 VCP W SG T Shown 1 Lock out Tag out Ring 4 KirkTM Key Interlock 7 Lift Pull Handle 2 Friction Hinge 5 Spring Loaded...

Page 10: ...une 2016 www eaton com 50 75 150 VCP W Selectable Ground and Test Device Figure 3 3 b Rear External View of 150 VCP W SG T Device Back External View 150 VCP W SG T Shown 1 Lifting Point 2 Primary Disc...

Page 11: ...als in the switchgear compartment Figure 3 5 4 3 GROUNDING CONTACTS The grounding contact is an assembly of spring loaded fingers which ground the device by engaging the switchgear cell grounding bus...

Page 12: ...4 5 Primary Disconnect Shim Removal 3000A Figure 4 8 Primary Disconnect Installed 1200A 2000A Figure 4 6 Primary Disconnect Installation 1200A 2000A Figure 4 4 Primary Disconnect Removal 3000A Figure...

Page 13: ...roperly stored to avoid potential damage Figure 4 4 Note N Ensure shims are installed as shown in Figure 4 5 for the 3000A configuration c THE GROUND AND TEST CODE PLATE MUST BE CHANGED AT THIS TIME T...

Page 14: ...IN THE NEUTRAL POSITION b For SG T devices equipped with Kirk Locks on the terminal access doors use the Kirk key provided to release the special bolt that is held by the Kirk locking system Slide th...

Page 15: ...5 3 Selector Blade Figure 5 6 Utilizing Hot Stick To Engage Selector Blade Figure 5 5 Selector Blade Disengaged Shown in Upper Position Figure 5 7 Selector Blade Engaged Shown in Upper Position Figure...

Page 16: ...IER WHEN PUSHING A SG T INTO A CELL FAILURE TO DO SO COULD RESULT IN BODILY INJURY IF FINGERS BECOME WEDGED BETWEEN THE SG T AND THE CELL USE BOTH FULLY OPENED HANDS FLAT ON THE FRONT OF THE SG T TO A...

Page 17: ...e In Connect Position Figure 5 12 Removing SG T using Lift Pull Handle To remove the SG T from the cell install the extension guide rails Pull up on the Lift Pull Handle as shown in Figure 5 12 then p...

Page 18: ...uired to cut dirt used Stoddard s Solvent Eaton part number 55812CA or commercial equivalent Hardware Visually inspect all hardware Replace any damaged or missing hardware with parts equivalent to tho...

Page 19: ...ating experience 7 1 1 ORDERING INSTRUCTIONS 1 Always specify the selectable ground and test device rating information and general order number from the nameplate 2 Describe the item give the style nu...

Page 20: ...ulevard Cleveland OH 44122 United States Eaton com 2016 Eaton All Rights Reserved Printed in USA Publication No IB182312EN June 2016 Eaton is a registered trademark All trademarks are property of thei...

Reviews: