background image

DGM**-5 30 Design

ISO4401 Size 05; 

ANSI/B93.7M-D05

Summary of Contents for SystemStak DGM-5-30 Series

Page 1: ...DGM 5 30 Design ISO4401 Size 05 ANSI B93 7M D05 ...

Page 2: ...o a subplate or manifold with a drain port to externally drain the DGMR1 at the mounting face 2 Valves acting in the service lines A and or B DGMC Relief valve DGMC2 Dual relief valve DGMDC Direct check DGMPC Pilot operated check DGMFN Flow control DGMR Counterbalance The general rule for this group is that the DGMC system relief valve be the farthest valve from the directional valve When using a ...

Page 3: ...ves should normally be positioned next to the mounting surface i e at the bottom of the stack When both a flow control and a pilot operated check valve is required it is recommended that the flow control valve be between the check valve and the actuator to prevent check valve chatter A combination of directional valve SystemStak valve s and subplate manifold block Figure 5 single station subplate ...

Page 4: ...ducing relieving DGMX2 Piloted from and reduced 13 pressure in port P A or B Sequence DGMR1 Single port P sequence 17 Counterbalance DGMR Control in port T 20 Flow Control DGMFN Single or dual port meter in 24 or meter out Pilot operated check DGMPC Single in port A or B dual 29 in ports A and B Direct check DGMDC Single check in any port dual 32 check in ports A and B only ...

Page 5: ...t single type only Port drained into A A cylinder port B B cylinder port crossport type only T Tank port single or dual types Pressure range A 4 to 50 bar 60 to 725 psi B 4 to 100 bar 60 to 1450 psi F 4 to 200 bar 60 to 2900 psi G 4 to 315 bar 60 to 4500 psi Adjustment device H Knob adjuster K Micrometer knob with keylock W Screw with locknut External drain E External drain Omit for internal drain...

Page 6: ... TA TA B B A A DGMC 5 PT 30 P P TB TB TA TA B B A A DGMC 5 PT RC 30 P P TB TB TA TA B B A A DGMC 5 PT E 30 P P TB TB TA TA B B A A DGMC2 5 AB BA 30 P P TB TB TA TA B B A A DGMC 5 AT 30 P P TB TB TA TA B B A A DGMC 5 AT RC 30 P P TB TB TA TA B B A A DGMC 5 BT 30 P P TB TB TA TA B B A A DGMC 5 BT E 30 P P TB TB TA TA B B A A DGMC 5 BT E RC 30 DR DR RC DR RC DR RC G RC G DR G RC RC DR RC DR RC DR DR ...

Page 7: ...A and T caused by the addition of the SystemStak valve to a hydraulic circuit Insertion loss curves see top left 1 DGMC2 5 AT E BT E RC 30 DGMC 5 AT E RC 30 DGMC 5 BT E RC 30 2 DGMC 5 PT E RC 30 3 DGMC2 5 AB BA 30 DGMC 5 and DGMC2 5 Vented Pressure RC models only Not applicable for crossport models DGMC 5 and DGMC2 5 Pressure Override The pressure override chart below shows typical override of dif...

Page 8: ...ease pressure setting External drain port External connection port thread see table External drain port Plugged for internal drain External connection port thread type see table Remote control port RC models only External connection port thread type see table Hex key 4 5 32 Gage port External connection port thread type see table TB B P A TA 3rd angle projection Installation Dimensions DGMC 5 PT S...

Page 9: ...1 5 0 45 15 3 0 60 11 5 0 45 12 5 0 49 50 1 97 30 1 18 48 1 89 W models max ext Wrench size 13 5 0 53 4 mounting holes See page 8 for specifications 141 5 55 50 1 97 11 7 0 46 33 2 1 31 69 5 2 74 71 6 2 82 max External drain port Remote control port RC models only Hex key TB B P A TA 11 5 0 45 11 5 0 45 12 5 0 49 External drain port Plugged for internal drain 4 5 32 13 1 2 13 1 2 4 5 32 15 3 0 60 ...

Page 10: ...ckwise to increase pressure setting TA B P A TB Wrench size both ends 33 2 1 31 69 5 2 74 15 3 0 60 both ends 11 5 0 45 both ends both ends 12 5 0 49 both ends Hex key External drain port both ends Plugged for internal drain Adjust pressure A port Adjust clockwise to increase pressure setting 13 1 2 4 5 32 4 mounting holes 6 9 0 27 through 9 50 0 37 counterbore 36 5 1 44 deep for bolt extenders or...

Page 11: ...FPA D05 Mounting surface 14 0 0 55 128 5 04 37 1 46 11 7 0 46 31 3 1 23 71 6 2 82 max Adjust pressure A port Adjust clockwise to increase pressure setting TA B P A TB Wrench size both ends 69 5 2 74 Hex key Adjust pressure B port Adjust clockwise to increase pressure setting 40 1 57 4 mounting holes 6 90 0 27 through 9 50 0 37 counterbore 46 5 1 83 deep for bolt extenders order separately BKE 6M 6...

Page 12: ...models max ext 40 1 57 B A B A 10 2 0 40 10 2 0 40 128 5 04 128 5 04 4 mounting holes See above for specifications 4 mounting holes 6 90 0 27 through 9 50 0 37 counterbore 46 5 1 83 deep for bolt extenders order separately BKE 6M 60M M6 metric or BKE 4 60M 2500 20 UNC Torque 11 3 14 7 Nm 100 130 lb in ISO 4401 AC 05 4 A NFPA D05 Mounting surface ISO 4401 AC 05 4 A NFPA D05 Mounting surface Install...

Page 13: ...itioned in the P line see symbols on page14 The connection of the pilot control line determines at which port the reduced pressure is obtained For example PP pilot for reduced pressure in P port PA pilot for reduced pressure in A port PB pilot for reduced pressure in B port The A and B line models provide for reduced pressure when P is connected to A or B It allows free flow through the service po...

Page 14: ... TA B B A A DGMX2 5 PA 30 P T B P P TB TB B B A A DGMX2 5 PP E RC 30 DGMX2 5 PA E RC 30 P P TB TB TA B B A A DGMX2 5 PP RC 30 P P TB TB TA TA B B A A DGMX2 5 PB RC 30 P P TB TB TA TA B B A A DGMX2 5 PB E RC 30 P P TB TB TA TA B B A A P T B P P TB TB TA TA B B A A DGMX2 5 PA RC 30 P T B P P T B TA TA B B A A DGMX2 5N PP 30 X X Y Y P P TB TB TA TA B B A A DGMX2 5N PP E 30 X X Y Y P P TB TB TA TA B B...

Page 15: ...hich prevents undesirable pressure rise in the reduced pressure port Pressure Drop bar Pressure Drop psi 15 10 100 0 0 Flow l min Flow USgpm 20 40 60 80 100 120 5 10 15 20 25 30 5 50 25 20 150 200 250 300 350 A or B port P port T port Pressure bar Pressure psi 30 20 10 200 0 0 Flow l min Flow USgpm 20 40 60 80 100 120 5 10 15 20 25 30 400 A models B F G models Pressure bar Pressure psi 200 150 100...

Page 16: ...olt extenders order separately BKE 6M 60M M6 metric or BKE 4 60M 2500 20 UNC Torque 11 3 14 7 Nm 100 130 lb in 30 1 18 50 1 97 W models max ext Wrench size 11 5 0 45 ISO 4401 AC 05 4 A NFPA D05 Mounting surface 13 5 0 53 131 5 16 37 1 46 11 7 0 46 28 4 1 12 69 5 2 74 71 6 2 82 max 20 4 0 80 Adjust clockwise to increase pressure setting Note Back pressure in drain is added to this setting for inter...

Page 17: ...overall pressure range from 5 to 315 bar 75 4500 psi P P TB TB TA TA B B A A DGMR1 5 PP 30 P P TB TB TA TA B B A A DGMR1 5 PP E 30 G G DR Valve function Manifold or subplate mounted sequence valve Interface 5 ISO 4401 AC 05 4 A CETOP RP35H Size 5 ANSI NFPA D05 Port operated upon P Pressure port Pilot control P Pressure port Pressure range A 5 to 50 bar 75 to 725 psi B 5 to 100 bar 75 to 1450 psi F...

Page 18: ...sid 15 10 100 0 0 Flow l min Flow USgpm 20 40 60 80 100 120 5 10 15 20 25 30 5 50 25 20 Pressure bar Pressure psi 200 150 100 4000 3000 2000 0 0 Flow l min Flow USgpm 20 40 60 80 100 120 5 10 15 20 25 30 50 1000 300 350 250 5000 150 200 250 300 350 A or B port P port T port G max F max B max A max Minimum setting all models Spool held in open position Basic Characteristics Maximum flow 120 l min 3...

Page 19: ...ternal connection port thread 60 2 36 10 0 39 30 5 1 20 48 1 89 W models max ext Wrench size 11 5 0 45 ISO 4401 AC 05 4 A NFPA D05 Mounting surface 13 5 0 53 4 mounting holes 6 9 0 27 through 9 50 0 37 counterbore 46 5 1 83 deep for bolt extenders order separately BKE 6M 60M M6 metric or BKE 4 60M 2500 20 UNC Torque 11 3 14 7 Nm 100 130 lb in 130 5 12 37 1 46 11 7 0 46 28 4 1 12 69 5 2 74 71 6 2 8...

Page 20: ...tak counterbalance valves provide continuous protection from pump cavitation and prevent an actuator from running ahead of the pump supply These valves also provide thermal relief protection in closed systems NOTE Counterbalance valves adjust in the opposite direction of other pressure control valves Turning the adjuster counterclockwise increases the valve setting Turning the adjustment clockwise...

Page 21: ...t open through service port of counterbalance Pressure Drop bar Pressure Drop psid 30 20 300 0 0 Flow l min Flow USgpm 20 40 60 80 100 120 5 10 15 20 25 30 10 150 60 40 450 600 750 50 4 3 Pressure Drop psid 4 0 Flow l min Flow USgpm 40 80 10 20 2 20 1 30 120 2 40 20 60 100 0 3 1 10 30 50 Pressure Drop bar 5 1 5 2 5 Basic Characteristics Maximum flow 120 l min 32 USgpm Load holding leakage 70 of pr...

Page 22: ...models max ext both ends Wrench size ISO 4401 AC 05 4 A NFPA D05 Mounting surface 4 mounting holes 6 90 0 27 through 9 50 0 37 counterbore 46 5 1 83 deep for bolt extenders order separately BKE 6M 60M M6 metric or BKE 4 60M 2500 20 UNC Torque 11 3 14 7 Nm 100 130 lb in 155 5 6 12 50 1 97 11 7 0 46 33 2 1 31 69 5 2 74 71 6 2 82 21 5 0 85 13 5 0 53 3rd angle projection Hex key 4 5 32 13 1 2 Adjust c...

Page 23: ...ISO 4401 AC 05 4 A NFPA D05 Mounting surface 4 mounting holes see page 22 142 6 5 61 50 1 97 11 7 0 46 33 2 1 31 69 5 2 74 71 6 2 82 Hex key 21 5 0 85 60 2 36 65 6 2 58 W models max ext Wrench size ISO 4401 AC 05 4 A NFPA D05 Mounting surface 142 6 5 61 11 7 0 46 33 2 1 31 69 5 2 74 71 6 2 82 Hex key 21 5 0 85 60 2 36 4 mounting holes see page 23 Wrench size 13 1 2 4 5 32 4 5 32 13 1 2 Adjust coun...

Page 24: ...e 5 RP35H ANSI NFPA D05 Direction of flow X Meter in Y Meter out Port operated upon A Cylinder port A single or dual type B Cylinder port B single type only P Pressure port single type only Adjustment range 1 Fine control 2 Normal control Adjustment device H Knob adjuster K Micrometer knob with keylock W Screw with locknut Port operated upon second function Omit for single flow control models B B ...

Page 25: ...model code page 24 Graph 3 Free flow pressure drop across check valve Note Turn or Turns on curves in graphs 1 and 2 above refer to turn of adjustment device from fully closed position Graph 3 1 P port of all models except DGMFN 5 X P 30 B and T ports of DGMFN 5 X P 30 2 T port of all models except DGMFN 5 X P 30 A ports of DGMFN 5 X P 30 3 Pressure drop across reverse free flow check valve Pressu...

Page 26: ...4401 AC 05 4 A NFPA D05 Mounting surface 50 1 97 A W models max ext 13 5 0 53 128 5 04 37 1 46 11 7 0 46 B 71 6 2 82 max B P A TB Wrench size 69 5 2 74 Hex key Rotate clockwise to decrease flow 30 1 18 139 5 47 No hex plug on DGMFN 5 X P models 3rd angle projection 13 1 2 4 5 32 50 1 97 52 7 2 07 W models max ext ISO 4401 AC 05 4 A NFPA D05 Mounting surface 13 5 0 53 128 5 04 37 1 46 11 7 0 46 33 ...

Page 27: ...05 Mounting surface 13 5 0 53 128 5 04 37 1 46 11 7 0 46 33 2 1 31 71 6 2 82 max B P A Wrench size 69 5 2 74 20 0 79 139 5 47 50 1 97 52 7 2 07 W models max ext 13 5 0 53 128 5 04 37 1 46 11 7 0 46 33 2 1 31 71 6 2 82 max B P A Wrench size 69 5 2 74 Hex key 30 1 18 139 5 47 Rotate clockwise to decrease flow 4 mounting holes See page 27 for specifications 4 mounting holes See page 27 for specificat...

Page 28: ...8 ISO 4401 AC 05 4 A NFPA D05 Mounting surface Rotate clockwise to decrease flow in port B Rotate clockwise to decrease flow in port A 50 1 97 52 7 2 07 W models max ext typ both ends 128 5 04 37 1 46 11 7 0 46 33 2 1 31 71 6 2 82 max B P A Wrench size both ends 69 5 2 74 20 0 79 ISO 4401 AC 05 4 A NFPA D05 Mounting surface Rotate clockwise to decrease flow in port B Rotate clockwise to decrease f...

Page 29: ... A1 PB Pressure at B PB1 Pressure at B1 In the above cases substitute cracking pressure and area ratio from the following Cracking pressure 1 2 5 or 5 bar according to model code position 6 and position 10 for second function Area ratio factors Standard valve 3 Decompression poppet 20 PA PC PA1 Area ratio factor Pressure at B1 PA1 PB PC PB1 Area ratio factor Pressure at A1 PB1 Model Code Valve fun...

Page 30: ...ting Data Performance Data DGMPC Pressure Drop The curves below show pressure drop through each functional flow path in the valve The total insertion loss for the valve must be calculated by summing the losses through the four applicable flow paths ModelType Curve Number P T A B DGMPC 5 D AB 30 1 2 5 3 4 DGMPC 5 D BA 30 1 2 3 5 4 DGMPC 5 D AB D BA 30 1 2 5 5 Flow toward actuator without check sing...

Page 31: ...mensions 30 1 18 50 1 97 9 9 0 39 ISO 4401 AC 05 4 A NFPA D05 Mounting surface 13 5 0 53 128 5 04 37 1 46 11 7 0 46 33 2 1 31 71 6 2 82 max B P A TB 69 5 2 74 4 mounting holes 6 9 0 27 through 9 50 0 37 counterbore 36 5 1 44 deep for bolt extenders order separately BKE 6M 50M M6 metric or BKE 4 50M 2500 20 UNC Torque 11 3 14 7 Nm 100 130 lb in 9 9 0 39 TA ...

Page 32: ...D05 Direction of flow X Free flow from actuator load Y Free flow to actuator load Check location A Check in cylinder port A Y models only B Check in cylinder port B Y models only P Check in pressure port P Y models only T Check in tank port TA X models only Cracking pressure K 1 0 bar 15 psi M 2 5 bar 35 psi N 5 0 bar 75 psi Check location second function Omit for single check models B Check in cy...

Page 33: ... through cylinder port without check Flow from actuator through cylinder port without check Use K M or N curve from graph 3 as applicable N M K Pressure Drop bar Pressure Drop psi 15 10 100 0 0 Flow l min Flow USgpm 20 40 60 80 100 120 5 10 15 20 25 30 5 50 25 20 150 200 250 300 350 T A B N M K Graph 1 Pressure Drop bar 15 10 100 0 0 Flow l min Flow USgpm 20 40 60 80 100 120 5 10 15 20 25 30 5 50 ...

Page 34: ...etric or BKE 4 50M 2500 20 UNC Torque 11 3 14 7 Nm 100 130 lb in 9 9 0 39 max 50 1 97 ISO 4401 AC 05 4 A NFPA D05 Mounting surface 13 5 0 53 30 1 18 9 9 0 39 max 50 1 97 ISO 4401 AC 05 4 A NFPA D05 Mounting surface 13 5 0 53 17 669 9 9 0 39 max 4 mounting holes See above for specifications 4 mounting holes See above for specifications TA Installation Dimensions DGMDC 5 Y A B 30 Dual Direct Check V...

Page 35: ... Wrench size Knob Adjusters DGMC DGMC2 dual type DGMR1 DGMX2 DGMC2 crossport type DGMFN DGMR Adjustment of valve setting is only possible while key is inserted and turned to engage driving pin When key is removed adjuster knob can be freely spun and does not engage with setting mechanism Adjustment of valve setting is only possible while key is inserted and turned to engage driving pin When key is...

Page 36: ...02 E April 2015 N 36 N Mounting Surface Dimensions mm inches DGM 5 The 5 interface accepts Ea ton DG4S4 directional valves and other directional valves with a standard ISO 4401 05 NFPA D05 ANSI B93 7M size D05 or CETOP 5 port pattern ...

Page 37: ...lacement without disturbing the stack assembly There are 4 bolt extenders per kit Bolt extender cross section Example of bolt extenders on a typical SystemStak assembly SystemStak Valve Height Metric Inch ExtenderTorque mm inch Thread Kit Model Number Thread Kit Model Number 50 1 97 M6 x 1 6H BKE 6M 50M 2500 20 UNC BKE 4 50M 11 3 14 7 Nm 100 130 lbf in 60 2 36 M6 x 1 6H BKE 6M 60M 2500 20 UNC BKE ...

Page 38: ... 00 B T P A B 10 4 41 10 4 41 23 9 94 92 3 62 46 1 8 23 1 91 47 8 1 88 23 1 91 68 3 2 69 18 3 72 23 9 94 A 101 6 4 00 114 3 4 50 43 7 1 72 20 6 81 5 6 22 15 8 62 5 6 22 28 5 1 12 79 4 3 12 33 02 1 30 12 7 50 54 2 12 37 3 1 47 26 16 1 03 15 59 6 35 25 11 2 44 R 11 9 47 R P Pressure Conn 10 3 41 D Thru 20 6 81 D Spotface 4 holes for mounting 438 Dia System ports 4 holes 2500 20 UNC 2B Thd 4 holes fo...

Page 39: ... size SAE straight thread 114 3 4 50 92 0 3 625 46 0 1 812 32 5 1 281 21 4 844 6 35 250 43 6 1 72 4375 dia 4 places Pilot port 5P only 5625 18 UNF SAE straight thread Plug if internally piloted X size SAE str thd X size SAE str thd X size SAE str thd A X P B T Y Drain port 5P only 5625 18 UNF SAE straight thread Plug if internally drained 421 dia thru 656 dia c bore 468 deep 4 places 3 17 125 dia ...

Page 40: ... 39 6 1 56 X size SAE str thd Spotface 2 4 094 deep 4 places 19 75 Pilot port 5P only 5625 18 SAE str thd Plug if internally piloted Drain port 5P only 5625 18 UNF SAE str thd Plug if internally drained 2500 20 UNC 2B thd 12 7 50 deep 4 holes for mounting 11 2 44 2 4 094 2 4 094 11 1 437 11 1 437 Subplates Blanking Plates DGVM Bottom Ported Subplates rated at 315 bar 4500 psi 5 interface Model X A...

Page 41: ...EATON DGM 5 30 Design E VLST BB002 E April 2015 N 41 N ...

Page 42: ...344 USA Tel 952 937 9800 Fax 952 294 7722 www eaton com hydraulics Eaton Hydraulics Group Europe Route de la Longeraie 7 1110 Morges Switzerland Tel 41 0 21 811 4600 Fax 41 0 21 811 4601 Eaton Hydraulics Group Asia Pacific Eaton Building 4th Floor No 7 Lane280 Linhong Rd Changning District Shanghai 200335 China Tel 86 21 5200 0099 Fax 86 21 2230 7240 ...

Reviews: