![Eaton SystemStak DGM-5-30 Series Manual Download Page 9](http://html1.mh-extra.com/html/eaton/systemstak-dgm-5-30-series/systemstak-dgm-5-30-series_manual_4122937009.webp)
EATON
DGM**-5 30 Design E-VLST-BB002-E April 2015
N-9
N
ISO 4401-AC-05-4-A (NFPA D05) Mounting surface
4 mounting holes
(See page 8 for
specifications)
Adjust pressure “A” port. Adjust clockwise to increase pressure setting.
50
(1.97)
30
(1.18)
48 (1.89)
“W” models
(max. ext.)
Wrench size
ISO 4401-AC-05-4-A (NFPA D05)
Mounting surface
13,5 (0.53)
141 (5.55)
37 (1.46)
11,7 (0.46)
33,2
(1.31)
69,5
(2.74)
71,6
(2.82)
max.
Adjust pressure “B” port. Adjust clockwise to increase pressure setting.
External drain port *
Plugged for internal drain.
Remote control port. *
(“ RC” models only)
Hex key
T
A
B
P
A
T
B
11,5
(0.45)
15,3
(0.60)
11,5
(0.45)
12,5 (0.49)
50
(1.97)
30
(1.18)
48 (1.89)
“W” models
(max. ext.)
Wrench size
13,5 (0.53)
4 mounting holes
(See page 8 for specifications)
141 (5.55)
50 (1.97)
11,7 (0.46)
33,2
(1.31)
69,5
(2.74)
71,6
(2.82)
max.
External drain port *
Remote control port *
(“RC ” models only)
Hex key
T
B
B
P
A
T
A
11,5
(0.45)
11,5
(0.45)
12,5
(0.49)
External drain port *. Plugged for internal drain.
4 (5/32”)
13 (1/2”)
13 (1/2 ”)
4 (5/32”)
15,3 (0.60)
Installation Dimensions
DGMC-5-BT Single Relief
mm (inches)
See page 37 for optional adjustment devices.
See page 38 for interface dimensions.
* External connection port thread type:
“S” models - SAE-4 O-ring boss port
(0.4375-20 UNF-2B thread).
“B” models - G 1/8 (1/8 BSPF)
DGMC-5-AT Single Relief
• Back pressure in drain is added to this setting for
internal drain models only.