Glossary

Abbreviation

Meaning

PA/GA

Public Address and General Alarm

Sonix

Sonix PA/GA System

A&B

Duplicated PA/GA system architecture

N+1

Hot spare PA/GA system architecture

AB+

Sonix improved redundancy architecture

Hmi

Human interface

BGM

Background music

Tick-tone

Short burst of tone repeated every few seconds, used to check the output of connected loudspeakers

Sense Test

Periodic test carried by Sonix amplifi er to check integrity of 100 V line

100 V line

High voltage loudspeaker connection line at nominal 100 V ac

MCB

Miniature Circuit Breaker

RCBO

Residual current circuit breaker with overcurrent protection

Unit ID/Number

Unique identifi er assigned to each of Sonix module, used to identify it to the 2Mx and SAS.

Priority

Number assigned to a Sonix audio source to facilitate system usage confl ict resolution, 31 (highest) to 1 (lowest)

PTT

Push to talk

FAT

Factory Acceptance Test

SAT

Site Acceptance Test

Larson’s Effect

When a microphone is acoustically coupled to the loudspeaker and generates feedback

2Mx

Sonix 2Mx Central controller

Amp / 350-d

Sonix 350 W Power Amplifi er with 100 V line output

Eol1

Sonix Remote End of Line unit

Eol8

Sonix Amplifi er to 100 V line interface unit (8 channel)

SP AD

Sonix Intelligent loudspeaker monitoring unit

Hmi-Br

Sonix intrinsically safe barrier (ATEX/IECEx) for connecting Hmi-5 in explosive atmospheres

Hmi-Mute

Sonix 100V loudspeaker mute (Ex/SA)

Hmi-26

Sonix Human Interface access panel

Hmi-5

Sonix Small Human Interface access panel

Io

Sonix Input / Output unit

Ms12

Sonix 12-message digital message store

Pbx

Sonix Private branch exchange interface unit

Pm10

Sonix Power Management unit

Vw2

Sonix Beacon control and monitoring unit (2 channel)

SAS

Sonix Administration Software

Amp Bus

A 2Mx bus, used to communicate with and control Sonix Amplifi er units

HMI Bus

A 2Mx bus, used to communicate with and control Sonix Hmi units

I/O Bus

A 2Mx bus, used to communicate with and control Sonix input/output devices: IG, Io and Ms12

Beacon Bus

A 2Mx bus, used to communicate with and control Sonix Vw2 units

Power Bus

A 2Mx bus, used to communicate with and control Sonix Pm10 units

Global Bus

A 2Mx bus, used to communicate with SAS application

Sync

A 2Mx bus used to communicate with the second 2Mx unit when PA/GA system is confi gured as A&B, AB+ or N+1 

system

DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY

The information, recommendations, descriptions and safety notations in this document are based on Eaton Corporation’s 

(“Eaton”) experience and judgment and may not cover all contingencies. If further information is required, an Eaton sales 

office should be consulted. Sale of the product shown in this literature is subject to the terms and conditions outlined in 

appropriate Eaton selling policies or other contractual agreement between Eaton and the purchaser.
THERE ARE NO UNDERSTANDINGS, AGREEMENTS, WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING 

WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, OTHER THAN THOSE SPECIFICALLY 

SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES. ANY SUCH CONTRACT STATES THE ENTIRE 

OBLIGATION OF EATON. THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY 

CONTRACT BETWEEN THE PARTIES. 
In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability or 

other-wise for any special, indirect, incidental or consequential damage or loss whatsoever, including but not limited to 

damage or loss of use of equipment, plant or power system, cost of capital, loss of power, additional expenses in the use 

of existing power facilities, or claims against the purchaser or user by its customers resulting from the use of the informa-

tion, recommendations and descriptions contained herein. The information contained in this manual is subject to change 

without notice. 

Summary of Contents for SONIX Eol8

Page 1: ...SONIXTM Eol8 Termination Unit SonixTM Eol8 Technical Manual ...

Page 2: ...S FOR A PARTICULAR PURPOSE OR MERCHANTABILITY OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES In no event will Eaton be responsible to the purchaser or user in contract in tort including negligence strict liabil...

Page 3: ...s feedback 2Mx Sonix 2Mx Central controller Amp 350 d Sonix 350 W Power Amplifier with 100 V line output Eol1 Sonix Remote End of Line unit Eol8 Sonix Amplifier to 100 V line interface unit 8 channel SP AD Sonix Intelligent loudspeaker monitoring unit Hmi Br Sonix intrinsically safe barrier ATEX IECEx for connecting Hmi 5 in explosive atmospheres Hmi Mute Sonix 100V loudspeaker mute Ex SA Hmi 26 S...

Page 4: ...e box 6 5 3 Mounting the unit 6 5 4 Electrical Connections 6 5 4 1 EOL Bus connections RJ45 CAT6A 6 5 4 2 Loudspeaker loop connections Phoenix Contact blade terminals 7 5 4 3 Earth connection 7 5 4 4 Lightning Surge arresters 7 6 LOUDSPEAKER WIRING 8 6 1 Single loudspeaker loop wiring 8 6 2 Multiple loudspeaker loops per amplifier 8 6 3 Spur wiring 8 6 4 Post Amplifier Switching 8 6 5 Configuratio...

Page 5: ...fety whilst increasing operational features The Sonix PA GA System is designed to meet and surpass the requirements of ATEX IECEx DNV BV ABS IMO and PFEER with other regional certifications pending Please refer to Sonix system technical manual for any further information 4 About the product 4 1 Product description The Sonix PA GA system autonomously monitors and supervises the amplifier loudspeake...

Page 6: ...e unit Phoenix Contact SZG 0 6X3 5 VDE 1205121 M4 Nut spinner 7 mm Hex drive 5 2 In the box 1x Sonix Eol8 unit 1x Technical Manual 5 3 Mounting the unit The Sonix Eol8 is a DIN rail mount unit suitable to be installed on most standard EN 60715 rails EN 50022 Top hat TS35 TS35D type O or type Ω 35 x 7 5 15 mm rail EN 50045 mini Top hat or TS15 15 x 5 5 mm rail or EN 50035 type G or TS32 32 x 15 mm ...

Page 7: ...w impedance return for the Lightning arresters fitted to the unit It is recommended that the Earth connection be made to PE Protective Earth but if system is required to use TE Telecoms Instrumentation Earth then this is acceptable Warning The Earth connection must be connected properly terminated and checked during commissioning Cable sizing is as follows Recommended 4 0 mm2 Minimum 2 5 mm2 5 4 4...

Page 8: ...equires correct configuration of amplifier to support Eol1 unit 6 4 Post Amplifier Switching It is possible to utilise a relay set to control the audio output of an amplifier into multiple independent loudspeaker loops This can be done while also maintaining loop monitoring ote N This is considered ETO Engineer to Order please consult your local Eaton representative for exact configuration require...

Page 9: ...tem before proceeding Do not use sharp objects water aggressive cleaning agents or solvent to clean the unit Check the unit for visible damage scratches bumps Check unit fixing to rack tighten DIN rail loose screws Check connections and cable integrity replace damaged cables Remove dust and dirt from unit Clean the protective cover with a dry cloth clean the electronics with compressed air WARNING...

Page 10: ...Eaton and SONIX are registered trademarks All other trademarks are property of their respective owners Changes to the products to the information contained in this document and to prices are reserved so are errors and omissions Only order confirmations and technical documentation by Eaton is binding Photos and pictures also do not warrant a specific layout or functionality Their use in whatever fo...

Reviews: