background image

SONIX

TM 

Eol8

Termination Unit

Sonix

TM

 Eol8  Technical Manual

Summary of Contents for SONIX Eol8

Page 1: ...SONIXTM Eol8 Termination Unit SonixTM Eol8 Technical Manual ...

Page 2: ...S FOR A PARTICULAR PURPOSE OR MERCHANTABILITY OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES In no event will Eaton be responsible to the purchaser or user in contract in tort including negligence strict liabil...

Page 3: ...s feedback 2Mx Sonix 2Mx Central controller Amp 350 d Sonix 350 W Power Amplifier with 100 V line output Eol1 Sonix Remote End of Line unit Eol8 Sonix Amplifier to 100 V line interface unit 8 channel SP AD Sonix Intelligent loudspeaker monitoring unit Hmi Br Sonix intrinsically safe barrier ATEX IECEx for connecting Hmi 5 in explosive atmospheres Hmi Mute Sonix 100V loudspeaker mute Ex SA Hmi 26 S...

Page 4: ...e box 6 5 3 Mounting the unit 6 5 4 Electrical Connections 6 5 4 1 EOL Bus connections RJ45 CAT6A 6 5 4 2 Loudspeaker loop connections Phoenix Contact blade terminals 7 5 4 3 Earth connection 7 5 4 4 Lightning Surge arresters 7 6 LOUDSPEAKER WIRING 8 6 1 Single loudspeaker loop wiring 8 6 2 Multiple loudspeaker loops per amplifier 8 6 3 Spur wiring 8 6 4 Post Amplifier Switching 8 6 5 Configuratio...

Page 5: ...fety whilst increasing operational features The Sonix PA GA System is designed to meet and surpass the requirements of ATEX IECEx DNV BV ABS IMO and PFEER with other regional certifications pending Please refer to Sonix system technical manual for any further information 4 About the product 4 1 Product description The Sonix PA GA system autonomously monitors and supervises the amplifier loudspeake...

Page 6: ...e unit Phoenix Contact SZG 0 6X3 5 VDE 1205121 M4 Nut spinner 7 mm Hex drive 5 2 In the box 1x Sonix Eol8 unit 1x Technical Manual 5 3 Mounting the unit The Sonix Eol8 is a DIN rail mount unit suitable to be installed on most standard EN 60715 rails EN 50022 Top hat TS35 TS35D type O or type Ω 35 x 7 5 15 mm rail EN 50045 mini Top hat or TS15 15 x 5 5 mm rail or EN 50035 type G or TS32 32 x 15 mm ...

Page 7: ...w impedance return for the Lightning arresters fitted to the unit It is recommended that the Earth connection be made to PE Protective Earth but if system is required to use TE Telecoms Instrumentation Earth then this is acceptable Warning The Earth connection must be connected properly terminated and checked during commissioning Cable sizing is as follows Recommended 4 0 mm2 Minimum 2 5 mm2 5 4 4...

Page 8: ...equires correct configuration of amplifier to support Eol1 unit 6 4 Post Amplifier Switching It is possible to utilise a relay set to control the audio output of an amplifier into multiple independent loudspeaker loops This can be done while also maintaining loop monitoring ote N This is considered ETO Engineer to Order please consult your local Eaton representative for exact configuration require...

Page 9: ...tem before proceeding Do not use sharp objects water aggressive cleaning agents or solvent to clean the unit Check the unit for visible damage scratches bumps Check unit fixing to rack tighten DIN rail loose screws Check connections and cable integrity replace damaged cables Remove dust and dirt from unit Clean the protective cover with a dry cloth clean the electronics with compressed air WARNING...

Page 10: ...Eaton and SONIX are registered trademarks All other trademarks are property of their respective owners Changes to the products to the information contained in this document and to prices are reserved so are errors and omissions Only order confirmations and technical documentation by Eaton is binding Photos and pictures also do not warrant a specific layout or functionality Their use in whatever fo...