EATON CORPORATION

 www.eaton.com

Effective December 2010

 

Instructional Leaflet 

IL01301037E

Figure 6. Step 2

Step 3e: 

Become familiar with the fixed terminal block DIN rail 

type mounting plate where secondary connections  

are made. 

otee:

N

Secondary connection points have numerical and 

descriptive laser-etched identifications.

 

Figure 7. Step 3

Step 4e: 

Plug accessory connector plug into fixed secondary 

terminal block.

Figure 8. Step 4

4

3 5 7 9

11 13

15 17

19 21

23 25

27

OT1M OT2B OT2M

ALM1

ALM2

ALMC

OT2C

OT1B

OT1C

N2 G2

G1

N1

SGF1 AGND

CMM2

CMM1

+24V

SGF2

CMM4

CMM3

ZOOM

ZOU

T

UV2

UV1

6 8 

10 12

14

16 18

20

22

24

26

28

30

32

34

9 11 13

15 17

19 21

23 25

27

OT2B OT2M

ALM1

ALM2

ALMC

OT2C

OT1B

N2 G2

G1

N1

SGF1 AGND

CMM2

CMM1

+24V

SGF2

CMM3

8  10 12

14

16 18

20

22

Step 5e: 

Identify correct mounting location on fixed terminal 

block mounting plate for mounting fixed secondary terminal 

block. First insert the bottom end of the fixed secondary 

terminal block into the proper location on the DIN rail type 

mounting plate.

Figure 9. Step 5

Step 6e: 

Rotate the top end of the terminal block in until it 

engages the appropriate flexible mounting tab at the top of 

the mounting plate with a clicking sound.

Figure 10. Step 6

Step 7e: 

To remove a fixed secondary terminal block, lift up on 

small flexible mounting tab at the top of fixed terminal block 

mounting plate, and rotate the terminal block out in the oppo-

site direction shown in Step 6.

4

3

1 5 7 9

11 13 15 17

19 21 23

25 27

OT1M OT2B

OT2M ALM1

ALM2

ALMC

OT2C

OT1B

OT1C

N2

G2

G1

N1

SGF1 AGND

CMM2

CMM1

+24V

SGF2

CMM4

CMM3

ZOOM

ZOU

T

UV2

UV1

6 8 1012

14 16 18

20 22

24 26

28 30

32 34

14

13

Summary of Contents for Series NRX

Page 1: ...INSTRUCTIONS FOR REPAIR AND EXCHANGE MUST BE STRICTLY ADHERED TO PREVENT INJURY TO PERSONNEL AND DAMAGE TO THE SWITCHBOARD Section 1 General information A maximum of 27 terminal blocks providing 54 s...

Page 2: ...ed by squeezing two release tabs together with small needle nose pliers and pulling out Figure 4 Figure 4 Connector Plug Removal Customer wiring is done using tension clamp terminations Refer to manua...

Page 3: ...MM 1 24V SGF2 CMM 3 8 10 12 14 16 18 20 22 Step 5 Identify correct mounting location on fixed terminal block mounting plate for mounting fixed secondary terminal block First insert the bottom end of t...

Page 4: ...REASON ACCESSORY SECONDARY PLUGS DO NOT HAVE TO BE UNPLUGGED TO ADD OR REMOVE TERMINAL BLOCKS REFER TO FIGURES 3 AND 4 OF SECTION 1 AND THE ASSOCIATED COPY FOR ASSISTANCE WITH CONNECTING OR DISCONNECT...

Page 5: ...RF Frame Step 2 Remove the four mounting screws holding the termi nal block alignment bracket in place Figure 15 Step 2 Step 3 Carefully slide the alignment bracket out from between any mounted termi...

Page 6: ...positioned accurately Figure 18 Step 5 Step 6 Repeat Steps 4 and 5 until all terminal blocks are mounted and check to ensure they are positioned in the cor rect locations A small number of DIN rail m...

Page 7: ...t using the four screws removed previously in Step 2 Hand tighten the four mounting screws to complete the installation process Figure 22 Step 9 Step 10 To remove already mounted terminal blocks first...

Page 8: ...CONTRACT BETWEEN THE PARTIES In no event will Eaton be responsible to the purchaser or user in contract in tort including negligence strict liability or otherwise for any special indirect incidental o...

Page 9: ...ILE ABDECKEN ODER ABSCHRANKEN DAS GER T IST VOM NETZ ZU TRENNEN ES D RFEN NUR VOM HERSTELLER ZUGELASSENE ERSATZTEILE VERWENDET WERDEN DIE VORGESCHRIEBENEN WARTUNGSINTERVALLE SOWIE DIE ANWEISUNGEN F R...

Page 10: ...ker heraus gezogen wird siehe Abbildung 4 Abbildung 4 Entfernen der Anschlusstecker Kundenseitige Anschl sse werden mit Spannklemmen vorge nommen Siehe Handbuch MN01301001E AWB1230 1628 f r Anschlussd...

Page 11: ...Schritt 6 Schritt 7 Um einen Steuerleitungsanschlussblock zu ent fernen heben Sie die Halteklammer an ziehen Sie den Steuerleitungsanschlussblock nach vorne und heben Sie ihn heraus Der Verbindungsst...

Page 12: ...gssteckern des Schalters und der Steuerleitungsanschlussleiste der Kassette vertraut siehe Abbildung 1 Abschnitt 1 Anmerkung A Die Anschlusspositionen an den Steuerleitungsanschl ssen sind entsprechen...

Page 13: ...den Steuerleitungsanschlussblock auf die untere Anschlussleiste Abbildung 17 Schritt 4 Schritt 5 Lassen Sie den Steuerleitungsanschlussblock in die obere Anschlussleiste einschnappen Stellen Sie sich...

Page 14: ...hen Sie sie fest Abbildung 22 Schritt 9 Step 10 Um Steuerleitungsanschlussbl cke zu entnehmen entfenren Sie zuerst die Haltklemme Schritt 11 Um einen Steuerleitungsanschlussblock zu ent fernen setzen...

Page 15: ...rkway Moon Township PA 15108 United States 877 ETN CARE 877 386 2273 Eaton com 2010 Eaton Corporation All Rights Reserved Printed in USA Publication No IL01301037E Dezember 2010 PowerChain Management...

Reviews: