Eaton - Lighting Systems                                                       iLight Product Series - RI-2    73-897-00     IM8791     Iss 5                   3

Introduction

RI-2 provides a versatile interface between 

an iLight system and other control systems. 

This compact unit can be mounted virtually 

anywhere. It has eight inputs, which may be 

programmed to be either digital or analogue. 

The unit also has eight volt-free mains rated 

low power relays. These allow a wide range of 

external equipment to be controlled. All inputs 

and outputs are fully programmable as to their 

function. 

This interface allows the iLight iCANnet

TM

 

network to control other systems and other 

systems to communicate with the iCANnet

TM

 

network. RI-2 may be programmed to control 

curtains & blinds, screens, AV and other 

presentation equipment as well as controlling 

contactors for heavier power applications. With 

the control inputs set to analogue, any 0-10V 

source can be programmed to control system 

functions. The unit could also be programmed 

such that system sequences could be activated 

by a motion detector or other devices on 

the iCANnet

TM

 network. The adaptability and 

versatility of this product make it an essential 

item in larger, more sophisticated venues where 

more than just lighting control is required.

Weight: 

 

Packed: 2.6 kg
Unpacked: 2.4 kg

Specification

Electrical

Supply: 230 volts -/+ 10% 50/60 Hz  1 Amp
(optionally, 127 volt 60 Hz)
Protection: Requires external circuit breaker 

Internal Electronics fuse only

Load Types:   

8 x Volt free relays – changeover contacts rated 
23/-10% 50/60Hz 3A resistive maxC 

Terminal Sizes:

iCANnetTM cable size: 5 x 1.5mm

2

 

Control input cable size: 10 x 1.5mm

2

 

Switch output cable size: 9 x 1.5mm

2

 

Audio Visual Port cable size: 2 x 1.5mm

2

 

Relay output cable size: 24 x 1.5mm

2

Memory:

FLASH memory to be able to upgrade software
EEPROM for program and sequence memory

Environmental Data

Temperature: 2

0

C to 40

0

C

Humidity: +5 to 95% non-condensing

Dimensions

Summary of Contents for RI-2

Page 1: ...RI 2 Relay Interface Installation guide ...

Page 2: ...91 Iss 5 2 Contents Introduction 3 Weight 3 Dimensions 3 Specification 3 Mounting 5 Supply Wiring 5 iCAN Network Connections 6 Relay Outputs 7 Analog Digital Inputs 7 Digital Outputs 7 RS485 Connections 8 RJ12 Connector 9 Alarm Inputs 9 Service Switches and LEDs 10 ...

Page 3: ...any 0 10V source can be programmed to control system functions The unit could also be programmed such that system sequences could be activated by a motion detector or other devices on the iCANnetTM network The adaptability and versatility of this product make it an essential item in larger more sophisticated venues where more than just lighting control is required Weight Packed 2 6 kg Unpacked 2 4...

Page 4: ... voltage outputs Do not mix low voltage and line voltage on relay output terminals Normally open and Normally closed terminals available for each relay Low voltage volt free outputs Line voltage rated at 3 Amps AC for general use resistive incandescent lamps tungsten electric discharge ballast loads and HP AC motor loads for use at 120 VAC LED diagnostic indicators for relay status 8 Digital Outpu...

Page 5: ...th greater than 50mm is used Mounting Holes The unit is provided with four 1 4in 6mm diameter fixing holes for wall mounting The mounting holes can be accessed by undoing the four screws on the front cover and removing it Supply Wiring Connecting the Supply This unit requires a nominal 240V single phase supply Live Neutral and Earth with 1A capability Keep the supply wiring segregated from the rel...

Page 6: ...date warranty A maximum segment distance of 3200 ft 1000 m is possible if an additional 12V power supply is used iCAN devices are daisy chained on the network Spurs from the Network are not permitted and will result in communications problems Devices on an iCAN network can be wired in any order Termination is required at both ends of the network NetworkTermination T Indicates where a termination i...

Page 7: ...h can be configured via software for either digital or analog input signals Individually programmable to be analog or switch inputs Analog inputs accept 0 10VDC signals Note Wire distance from the device to the RI 2 should not exceed 32 feet 10m Connections are made via a 9 way two part connector with screw terminals The unit is supplied with knockouts suitable for 3 4 19mm cable glands for analog...

Page 8: ...d of the network ensure the appropriate jumper is fitted in the termination ON position as in the following diagram RS485 Connections An RS485 port is provided for connection to third party devices or PC integration The settings are Baud Rate 9600 Baud Data Structure No parity 8 data bits 1 start bit 1 stop bit A removable 4 way connector block is provided for the connection of RS485 Function Alar...

Page 9: ...tion for the alarm inputs is for all outputs to switch on These inputs are designed for integration with emergency control devices and building management systems using volt free switch inputs The default action for the alarm inputs is for all mapped DMX channels to output 255 digital outputs drive high and relay outputs close They will then remain in this state regardless of any other command rec...

Page 10: ...on the network The LEDs indicate the following Normal operation Steady green LED blinking 1 x per second Red LED off Message transmission and receipt indicated by red LED flashing for duration of data transmission Override status Both LEDs flashing together or just red flashing and green off ICANnet error status will occur when a Source Controller is not connected to an iCAN network for any reason...

Page 11: ...tput s should this be suspected When the Source Controller is placed into override mode it will no longer respond to commands sent over the iLight network Override mode can also be used to restore power to outputs if control is lost or termporarly removed to allow lighting to remain on until control is restored NOTE Override mode only affects the outputs on the Source Controller on which it is act...

Page 12: ...ITY AND THE IMPLIED WARRANTY OF FITNESS No employee agent dealer or other person is authorised to give any warranties on behalf of the Seller or to assume for the Seller any other liability in connection with any of its goods except in writing and signed by the Seller The Seller makes no representation that the goods comply with any present or future federal state or local regulation or ordinance ...

Reviews: