Background of this function:
In earlier MRF versions the old Status message has only been sent by an actuator that was
connected to an intelligent device if there was at least a reception quality >0% between the two
devices (defined by the connection calculation in the MRF). Therefore it could have been possible
that actuators that were switched by an intelligent device by routing never sent their status back.
Since Version 2.30 the sending of the Status of an old actuator can be activated independent of
the reception quality using the option ‘Send old Status message’ in the configuration window of
each actuator. If deactivated the status message will not be sent like in earlier versions when there
was no reception quality between the devices. When activated the status message will always be
sent. Per default this option is activated. The reason for this change is that new generation
actuators and Routers can resend the old status message and forward it to intelligent devices if
there is no direct connection possible (successful calculation of resenders necessary).
Reset all Devices
All the devices which are
and can be seen on the screen will be reset to the state at the
time of their delivery.
All the parameterizations and assignments will be deleted. In case a
before, it will also be deleted from the xComfort devices.
The devices will be reset to the state at the time of their delivery.
Load all Devices
This command re-loads the complete configuration into all the devices.
This option can be used, for example, if any modifications have been carried out later and you
want to make sure that all the devices will be loaded with the complete data, whether any
modifications have been made to the individual devices or not.
Specific info what happens while loading a device you can find
View Traffic
The command View Traffic opens a window that displays messages (commands, data) transmitted
via radio-frequency.
You will find this command under menu item Actions and View Traffic or by left-clicking the
symbol.
The window is set up the following way:
Line: Shows the line number for a message in the RF-monitor
Time: Shows at what time a message (command, data) has been sent.
Time difference: Shows the time difference to the previous message
Summary of Contents for RF System 2.42
Page 1: ...Eaton RF System 2 42 Manual...
Page 123: ...123 Eaton RF System 2015 Eaton Electrical Group State Syntax of RM to user...
Page 193: ...193 Eaton RF System 2015 Eaton Electrical Group...
Page 200: ...200 Eaton RF System Help 2015 Eaton Electrical Group 7 And assign the function Blinking to it...
Page 223: ...223 Eaton RF System 2015 Eaton Electrical Group Group settings analogue actuator...
Page 224: ...224 Eaton RF System Help 2015 Eaton Electrical Group Group settings heating actuator...
Page 225: ...225 Eaton RF System 2015 Eaton Electrical Group Group settings binary input battery supplied...
Page 227: ...227 Eaton RF System 2015 Eaton Electrical Group Group settings Temperature input...