 This manual describes the following models:

 

PXS24E-e2/F 

Economy (no 

communication port) 

2A 

fix 

with input 

terminals 

PXS24E02A002 

PXS24E-e4/F 

Economy (no 

communication port) 

4A 

fix 

with input 

terminals 

PXS24E04A002 

PXS24E-e6/F 

Economy (no 
communication port) 

6A 
fix 

with input 
terminals 

PXS24E06A002 

PXS24E-e8/F 

Economy (no 
communication port) 

8A 
fix 

with input 
terminals 

PXS24E08A002 

PXS24E-e10/F 

Economy (no 
communication port) 

10A 
fix 

with input 
terminals 

PXS24E10A002 

PXS24E-e2/F-IT 

Economy (no 

communication port) 

2A 

fix 

without input 

terminals 

PXS24E02A001 

PXS24E-e4/F-IT 

Economy (no 
communication port) 

4A 
fix 

without input 
terminals 

PXS24E04A001 

PXS24E-e6/F-IT 

Economy (no 
communication port) 

6A 
fix 

without input 
terminals 

PXS24E06A001 

PXS24E-e8/F-IT 

Economy (no 
communication port) 

8A 
fix 

without input 
terminals 

PXS24E08A001 

PXS24E-e10/F-

IT 

Economy (no 

communication port) 

10A 

fix 

without input 

terminals 

PXS24E10A001 

 

INPUT 
TERMINALS 

 

Articles marked “IT” (= “input terminal”) can be used individually (> see section on “stand-alone 
operation”) or in combination with other articles. Should you wish to combine several components 
(including for mixed operation), please consult the PXS24 system manual.

 

STAND-ALONE 
OPERATION 

 

An individual PXS24E-…/IT element can be used for the protection of a channel. This requires the 
selection of a model with input terminals (“IT”), as models without input terminals are supplied via the 
busbar only.

 

TEMPERATURE 
RISE 

 

To ensure thermal protection, modules with high amperage should not be placed directly next to one 
another, wherever possible. Please also refer to the technical data of the individual components.

 

De-rating: If three or more 16A modules are placed directly next to each other (in the specified 
temperature range), these must be de-rated to 13A. For this type of application, we therefore 
recommend using 13A modules instead. If 16A modules are to be used, please leave 1HP (18mm) 
between each of the modules for cooling purposes.

 

TECHNICAL DATA 

 

Marking 

CE 

Certification 

UL508 + UL2367 (section 10 and 12) 

Product standard 

Applicable sequences of: 
EN60947-1, EN60947-5-1, EN61009-1, 
EN61131-2 and EN61000-4-2 
Details acc. to Werksnorm WN 1008  

Summary of Contents for PXS24 Series

Page 1: ...ugenia 1 A 3943 Schrems MA PXS24_Economy docx 02 2018 www eaton eu documentation 1 150501508 IL019189ZU Technical Manual page 3 PXS24 Economy Technisches Handbuch Seite 7 PXS24 Economy Manuale Tecnico pagina 11 PXS24 Economy en de it ...

Page 2: ... PXS24E Economy series 4 Input terminals 4 Stand alone operation 4 Temperature rise 4 Technical data 4 Technisches Handbuch DE 7 Warnhinweise 7 Das System PXS24 7 Die Serie PXS24E Economy 8 Eingangsklemmen 8 Stand alone 8 Erwärmung 8 Technische Daten 8 Manuale Tecnico IT 11 Avvertenze di pericolo 11 Il sistema PXS24 11 La serie PXS24 Economy 11 Morsetti di alimentazione 12 Funzionamento indipenden...

Page 3: ...n automation applications Whenever the modules are switched on i e when operating voltage is applied they are live provided that the slide switch at the front is set to I If the unit has tripped following an overload or short circuit switching it off and back on again will reset the trip Please refer to the technical data of the individual components particularly the operating voltage and the rate...

Page 4: ...rminals PXS24E10A001 INPUT TERMINALS Articles marked IT input terminal can be used individually see section on stand alone operation or in combination with other articles Should you wish to combine several components including for mixed operation please consult the PXS24 system manual STAND ALONE OPERATION An individual PXS24E IT element can be used for the protection of a channel This requires th...

Page 5: ... 5 1 HP Height 92 5mm Depth 119 2mm Input terminals optional 3 x LINE and 3 x GND Output terminals 3 x LOAD and 3 x GND Terminal type Push in terminals Terminal capacity 2 5mm flexible with ferrule 4mm rigid Busbar LINE and GND max 80A In different lengths up to 1m Assembly Snap fit onto the TH35 mounting rail EN 60715 Status LED Two colored Green OK Red Tripped Off channel not in operation Slide ...

Page 6: ...1 A 3943 Schrems MA PXS24_Economy docx 02 2018 www eaton eu documentation 6 150501508 IL019189ZU Circuit diagram and terminal assignment for models with input terminals Circuit diagram for models without input terminals February 2018 V 1 04 ...

Page 7: ...k gebrauchlich sind Bei jedem Einschalten Anlegen der Betriebsspannung sind die Module aktiv solange der Schiebeschalter in der Front auf I steht D h ein Auslosen nach Uberlast oder Kurzschluss ist mit einem Aus und wieder Einschalten der Betriebsspannung geloscht Bitte beachten Sie die technischen Daten der einzelnen Komponenten besonders Betriebsspannung und Nennstrom DAS SYSTEM PXS24 Die Kompon...

Page 8: ...KLEMMEN Artikel mit IT input terminal konnen alleine siehe Abschnitt stand alone oder im Verbund mit anderen verschient verwendet werden Fur die Verwendung von mehreren Komponenten auch gemischt bitte das Handbuch PXS24 System beachten STAND ALONE Ein PXS24E IT Element kann alleine zur Absicherung eines Kanals verwendet werden Dazu ist ein Modell mit Eingangsklemmen IT zu wahlen Modelle ohne Einga...

Page 9: ... 92 5mm Tiefe 119 2mm Eingangsklemmen optional 3x LINE und 3x GND Ausgangsklemmen 3x LOAD und 3x GND Klemmenart Push In Klemmen Klemmenkapazitat 2 5mm flexibel mit Adernendhulse 4mm starr Verschienung LINE und GND max 80A In verschiedenen Langen bis 1m Montage Schnappbar auf Tragschiene TH35 EN 60715 Status LED Zweifarbig Grun OK Rot Ausgelost Aus Kanal nicht in Betrieb Schiebeschalter Ein Aus Res...

Page 10: ...ugenia 1 A 3943 Schrems MA PXS24_Economy docx 02 2018 www eaton eu documentation 10 150501508 IL019189ZU Schaltbild und Klemmenanordnung fur Modelle mit Eingangsklemmen Schaltbild bei Modellen ohne Eingangsklemmen Februar 2018 V 1 04 ...

Page 11: ...protetti dai sovraccarichi e a porva di corto circuito comunemente utilizzati nelle applicazioni di automazione Consultare i dati tecnici dei singoli componenti in particolare la tensione d esercizio e la corrente nominale IL SISTEMA PXS24 Sono disponibili molte opzioni per combinare i vari componenti della serie PXS24 Per evitare di limitare questa flessibilità sono disponibili due serie separate...

Page 12: ... con suffisso IT morsetto d ingresso possono essere utilizzati autonomamente confronta la sezione su funzionamento indipendente o in combinazione con altri moduli Se desideri combinare molti componenti compreso il funzionamento misto consulta il manuale del sistema PXS24 FUNZIONAMENTO INDIPENDENTE Un singolo elemento PXS24E IT può essere utilizzato da solo per proteggere un canale A tal fine è nec...

Page 13: ...ICHI e 3 x TERRA Tipo di morsetto Morsetti ad innesto Capacità del terminale 2 5 mm cavo flessibile con puntalino 4 mm cavo rigido Sbarra collettrice LINEA e TERRA max 80 A Sbarra collettrice Assemblaggio Disponibile in diverse lunghezze fino a 1m Fissaggio a scatto sulla guida DIN TH35 EN 60715 LED di stato bi colore verde OK rosso sganciato OFF canale non in uso Interruttore a scorrimento On Off...

Page 14: ...ustries Austria GmbH Eugenia 1 A 3943 Schrems MA PXS24_Economy docx 02 2018 www eaton eu documentation 14 150501508 IL019189ZU Schema elettrico per i modelli senza morsetti di alimentazione Febbraio 2018 V 1 04 ...

Reviews: