Eaton Compressor Rotary Screw Compressor
30
1.
Make sure repairs are done in a clean, dry, well lighted and ventilated area.
2.
When cleaning, use air pressure less than 30 psig (2.1bar). Also use effective chip guarding and personal
protective equipment per OSHA standard 29 CFR 1910.242 (b).
3.
Relieve all internal pressure prior to opening any line, fitting, hose, valve, drain plug, connection or other
component, such as filters and line oilers, and before refilling optional air line anti-icer systems with antifreeze
compound.
4.
Keep sound reducing material, any external surfaces of the air compressor or internal surfaces of the enclosure
free from fluids and build-up. Clean with water based industrial cleaner or steam clean as necessary. Remove
then replace sound reducing materials as needed to clean all surfaces. Immediately replace any sound reducing
material with torn or punctured protective covering to prevent accumulation of liquids or build-up inside the
material. NEVER use flammable solvents for cleaning purposes.
5.
Keep electrical wiring, including all terminals and pressure connectors in good condition. Replace any wiring that
has cracked, cut, or otherwise damaged insulation. Replace terminals that are worn, discolored or corroded.
Keep all terminals and pressure connectors clean and tight.
6.
Keep all body parts and any hand-held tools or other conductive objects away from exposed live parts of the
electrical system. When making repairs or adjustments, stand on a dry, insulated surface and DO NOT contact
any other portion of the compressor.
7.
DO NOT leave compressor unattended with exposed electrical components. Be sure to tag and disconnect all
power if temporary absence is necessary.
1.
Shut down compressor and allow machine to set for 5-10 minutes.
To avoid water condensation during operation, keep oil temperature between 160° - 190° F (70° - 88° C). Failure to do so
causes pump damage. Contact Eaton Compressor service if temperature drops below 160° F (70° C).
CAUTION
Compressor components can become hot during operation. Avoid
bodily contact with hot liquids, hot surfaces and sharp edges and
corners, or burns or personal injury could result.
Lubricating Oil
Changing Oil
Air/Oil Separator tank is a pressurized component. To avoid serious
injury, be sure system pressure is relieved before removing fill plug.
Be aware oil temperature may be very hot. Use caution when opening
fill plug.
WARNING