Operating Instructions
17
Resetting Maintenance Alarms
Maintenance Notifications
Following replacement times are important for safe
operation. Remember to clear lifetime and reset
maintenance timer after replacements are made.
Refer to PLC manual for more details.
Arrow down to Wt4 (Unload delay time). Press
Enter and the time flashes and can be changed
by using the Up & Down Arrows. Press Enter
again to confirm the setting. (See chart on page
17 of PLC manual.)
Once satisfied with all settings, press Down
Arrow until you are back to the Main Screen.
Press the two arrow keys at the same time to
bring up the Password Level Selection- Press
down arrow 2 times to select Level 3 then press
enter.
First screen for resetting alarms.
4
5
7
6
Component
(PLC)
Lifetime (hrs)
Air Filter
CAF
4000
Oil Filter
COF
4000
Air/Oil Separator Filter
CSF
4000
Lubricating Oil
C--=
4000
Check Compressor
C--h
4000
Motor Bearing Grease
BL
10,000