8
PowerXL DG1 and SVX Enclosed Drives Instructions
POWERXL DG1 AND SVX ENCLOSED DRIVES INSTRUCTIONS
IL040060EN April 2020 www.eaton.com
EGS 3D5 1 D 1
2 0 0 B 1 0 0 0 0
Power Disconnect Options
0
= None
1
= MCP disconnect
1
2
= Circuit breaker
3
= Circuit breaker/isolation fusing
4
= Circuit breaker/isolation fusing/3% input reactor
5
= Circuit breaker/isolation fusing/SPD
6
= Circuit breaker/isolation fusing/SPD/3% input reactor
7
= Circuit breaker/3% input reactor
8
= Circuit breaker/SPD
9
= Circuit breaker/SPD/3% input reactor
A
= Fused disconnect
B
= Fused disconnect/SPD
C
= Fused disconnect/SPD/3% input reactor
D
= Fused disconnect/3% input reactor
E
= Isolation fuses
F
= Isolation fuses/3% input reactor
G
= Isolation fuses/SPD
H
= Isolation fuses/SPD/3% input reactor
• = Custom option
2
Base Catalog Number Example
See
Page V6-T2-75
for base catalog
number selection.
Bypass Options
3
0
= None
1
= Manual HOA bypass
2
= Manual HOA bypass/isolation fusing
3
= Manual HOA bypass/isolation fusing/3% input reactor
4
= Manual HOA bypass/isolation fusing/SPD
5
= Manual HOA bypass/isolation fusing/SPD/3% input reactor
6
= Manual HOA bypass/3% input reactor
7
= Manual HOA bypass/SPD
8
= Manual HOA bypass/SPD/3% input reactor
H
= Manual HOA RVSS bypass
J
= Manual HOA RVSS bypass/isolation fusing
K
= Manual HOA RVSS bypass/isolation fusing/3% input reactor
L
= Manual HOA RVSS bypass/isolation fusing/SPD
M
= Manual HOA RVSS bypass/isolation fusing/SPD/3% input reactor
N
= Manual HOA RVSS bypass/3% input reactor
P
= Manual HOA RVSS bypass/SPD
R
= Manual HOA RVSS bypass/SPD/3% input reactor
• = Custom option
2
Output Power Options
4
0
= None
A
= Output contactor
B
= 3% Output reactor
D
= dV/dt filter
E
= 3% Output Reactor/output contactor
G
= dV/dt/output contactor
• = Custom option
2
Option Boards 2
Same options and codes as Option Boards 1
Option Boards 1
0
= No option
1
= 3 x DI, 3 x DO, 1 Thermistor, 24 Vdc/EXT
2
= 1 x AI, 2 x AO (isolated to control board)
3
= 3 x relay dry contact (2NO + 1NO/NC)
4
= 3 x PT100 RTD thermistor input
5
= 6 DI 240 Vac input
• = Custom option
2
Communication Options
0
= No option
1
= PROFIBUS-DP
3
= CANopen (slave)
4
= DeviceNet
5
= PROFIBUS-DP (D9 connector)
D
= SmartWire-DT
• = Custom option
2
Enclosure Options
0
= None
1
= Floor stand—12 inches
2
= Floor stand—22 inches
A
= Space heater
B
= Space heater & 12-inch floor stands
C
= Space heater & 22-inch floor stands
• = Custom option
2
Light Options
5
0
=None
1
=Non-bypass light kit—Power On, Run, Fault
2
=Bypass light kit—On, VFD Run, Fault, Bypass Run
• = Custom option
2
Control Options
5
0
=None
1
=Speed pot
2
= Start-stop pushbutton
3
= Start-stop pushbutton with speed pot
A
= HOA switch
B
= Start-stop pushbutton with speed pot & HOA switch
C
= Start-stop pushbutton with HOA switch
D
= HOA switch with speed pot
• = Custom option
2
Notes
1 HMCP disconnect option required and only available when bypass is selected.
2 More options are available as Engineered to Order through the Bid Manager tool.
3 All bypass options include third contactor for drive isolation when in bypass mode.
4 Output contactor not available with bypass. Bypass comes standard with output contactor.
5 Pilot devices are 22 mm standard. 30 mm options are available as engineered to order through the Bid Manager tool.