7
PowerXL DG1 and SVX Enclosed Drives Instructions
POWERXL DG1 AND SVX ENCLOSED DRIVES INSTRUCTIONS
IL040060EN April 2020 www.eaton.com
4.2 CATALOG NUMBER NOMENCLATURE
Each Catalog number consists of 18 digits, each digit or combination of digits in the catalog number indicates a rating,
feature or option. The catalog is located in PDF format on the website at www.eaton.com/drives
Notes
1
Brake chopper is a factory-installed option only. Braking resistors sold separately. See DG1 drives starting on
Page V6-T2-59
for selection.
2
Additional enclosure options including NEMA 4, 4X, 7 and 9 are available. Please contact the factory forconfiguration and pricing.
3
Part number configuration continued on the following page.
EGS 3D5 1 D 1
Product Family
EGS
= Enclosed DG1 drives - standard
Output Ampere Rating
208 V
230 V
480 V
3D5
= 3.5 A, 0.75 hp
4D6
= 4.6 A, 1 hp
6D6
= 6.6 A, 1.5 hp
7D5
= 7.5 A, 2 hp
010
= 10.6 A, 3 hp
016
= 16.7 A, 5 hp
024
= 24.2 A, 7.5 hp
030
= 30.8 A, 10 hp
046
= 46.2 A, 15 hp
059
= 59.4 A, 20 hp
074
= 74.8 A, 25 hp
088
= 88 A, 30 hp
114
= 114 A, 40 hp
143
= 143 A, 50 hp
169
= 169 A, 60 hp
211
= 211 A, 75 hp
273
= 273 A, 100 hp
3D2
= 3.2 A, 0.75 hp
4D2
= 4.2 A, 1 hp
6D0
= 6.0 A, 1.5 hp
6D8
= 6.8 A, 2 hp
9D6
= 9.6 A, 3 hp
015
= 15.2, 5 hp
022
= 22 A, 7.5 hp
028
= 28 A, 10 hp
042
= 42 A, 15 hp
054
= 54 A, 20 hp
068
= 68 A, 25 hp
080
= 80 A, 30 hp
104
= 104 A, 40 hp
130
= 130 A, 50 hp
154
= 154 A, 60 hp
192
= 192 A, 75 hp
248
= 248 A, 100 hp
312
= 312 A, 125 hp
2D1
= 2.1 A, 1 hp
3D0
= 3.0 A, 1.5 hp
3D4
= 3.4 A, 2 hp
4D8
= 4.8 A, 3 hp
7D6
= 7.6 A, 5 hp
011
= 11 A, 7.5 hp
014
= 14 A, 10 hp
021
= 21 A, 15 hp
027
= 27 A, 20 hp
034
= 34 A, 25 hp
040
= 40 A, 30 hp
052
= 52 A, 40 hp
065
= 65 A, 50 hp
077
= 77 A, 60 hp
096
= 96 A, 75 hp
124
= 124 A, 100 hp
156
= 156 A, 125 hp
180
= 180 A, 150 hp
240
= 240 A, 200 hp
302
= 302 A, 250 hp
Phasing, Voltage
1
= Input: Three-phase, 208 V
Output: Three-phase
2
= Input: Three-phase, 230 V
Output: Three-phase
4
= Input: Three-phase, 480 V
Output: Three-phase
5
= Input: Three-phase, 575 V
Output: Three-phase
J
= Input: Single-phase, 230 V
Output: Three-phase
K
= Input: Single-phase, 480 V
Output: Three-phase
Braking Application
1
A
= No brake chopper, low overload
B
= Brake chopper, low overload
C
= No brake chopper, high overload
D
= Brake chopper, high overload
Enclosure Rating
2
1
= NEMA Type 1
2
= NEMA Type 12
3
= NEMA Type 3R
6
= NEMA Type 1 Filtered and gasketed
•
= Custom option
_ _ _ _ _ _
Options
3
See
Page V6-T2-76
for catalog number
option selection.