Eaton Night Falcon/UFLD Installation Instructions Manual Download Page 1

INS #

Brand Logo  

reversed out of 

black

INS #

IB506007EN

WARNING

Risk of Burn – Disconnect power and allow fixture to 

cool before servicing.

otee:

N

These instructions do not claim to cover all 

details or variations in the equipment, procedure, 

or process described, nor to provide directions 

for meeting every possible contingency during 

installation, operation or maintenance. When 

additional information is desired to satisfy a 

problem not covered sufficiently for user’s purpose, 

please contact your nearest representative.

otee:

N

This lighting fixture has been shipped complete 

with one of several mounting options. Please follow 

the installation instructions specific to the catalog 

part that you ordered.

otee:

N

Care must be taken not to set lighting fixture down 

on optical lenses or lift the fixture in the lens area.

otee:

N

Specifications and dimensions subject to change 

without notice.

WARNING

Make certain power is OFF before starting installation 

or attempting any maintenance.

WARNING

Risk of fire/electric shock. If not qualified, consult an 

electrician.

WARNING

Risk of Electric Shock – Disconnect power at fuse or 

circuit breaker before installing or servicing.

WARNING

Risk of Personal Injury – Fixture may become damaged 

and/or unstable if not installed properly.

Do not mount luminaire within 6” of a combustible 

surface.

Do not handle luminaire by the glass. Do not touch 

LEDs.

IMPORTANTe:

 Read carefully before installing fixture. Retain for future reference.

Generale:

 Upon receipt of the fixture, thoroughly inspect for any freight damage which should be brought to the attention 

of the delivery carrier. Compare the catalog description listed on the packing slip with the fixture label on the housing to 

assure you have received the correct material.

Safetye:

 This fixture must be wired in accordance with the National Electrical Code and applicable local codes and 

ordinances. Proper grounding is required to insure personal safety. Carefully observe grounding procedure under 

installation section.

APPLICATIONSe:

 This lighting fixture is designed for outdoor lighting services, and should not be used in area of limited 

ventilation or inside high ambient temperature enclosures. It must be stored in a dry location prior to installation. Do 

not expose lighting fixture to rain, dust or other environmental conditions prior to installation and insertion of photo 

control or shorting cap (if so equipped). Do not install the fixture near combustible materials or locate next to airflow 

blocking surfaces within 6 inches. Best results will be obtained if installed and maintained according to the following 

recommendations.

Installation Instructions – Night Falcon/UFLD

Instructions d’installation – Night Falcon/UFLD

Instrucciones de instalación de Night Falcon/UFLD 

Summary of Contents for Night Falcon/UFLD

Page 1: ...t luminaire within 6 of a combustible surface Do not handle luminaire by the glass Do not touch LEDs IMPORTANT Read carefully before installing fixture Retain for future reference General Upon receipt...

Page 2: ...to step 2 if not skip to step 5 2 Remove 2 cover plate screws and cover plate with 2 Philips screwdriver 3 To change luminaire tilt angle loosen center bolt rotate fixture to the desired angle and tig...

Page 3: ...trols which specifically require the cell to be aimed north Otherwise pre selected factory orientation will function properly Follow the directions recommended by the photocontrol supplier for proximi...

Page 4: ...ools Required Phillips screwdriver 1 Loosen and remove the existing 4 10 24 Philips head screws on the face of the fixture 2 Align 4 7 8 spacers with existing holes 3 Use 4 10 24 x 1 1 2 screws to sec...

Page 5: ...se afin d assurer votre s curit Respectez soigneusement la proc dure de mise la terre du chapitre d installation APPLICATIONS Ce luminaire a t con u pour l clairage ext rieur et ne doit pas tre utilis...

Page 6: ...couvre joint en utilisant un tournevis cruciforme no 2 3 Pour modifier l angle d inclinaison desserrez le boulon de centrage tournez le luminaire l angle d sir puis serrez le boulon de centrage un co...

Page 7: ...s autres cas les r glages d finis en usine les rendront parfaitement fonctionnels Respectez les instructions fournies par le fournisseur de l interrupteur photo lectrique concernant la proximit avec d...

Page 8: ...7 Outils requis Tournevis cruciforme 1 Desserrez et retirez les quatre 4 vis t te cruciforme 10 24 situ es sur la face du luminaire 2 Alignez les quatre 4 entretoises de 22 2 mm avec les trous existan...

Page 9: ...minaci n en exteriores y no debe utilizarse en reas de ventilaci n limitada o dentro de recintos con temperaturas ambiente elevadas Debe almacenarse en una ubicaci n seca previamente a su instalaci n...

Page 10: ...los 2 tornillos de la placa de cubierta y la placa de cubierta con un destornillador Philips N 2 3 Para modificar el ngulo de inclinaci n de la luminaria afloje el perno central gire la luminaria hac...

Page 11: ...ntrario con la orientaci n preseleccionada en f brica funcionar correctamente Siga las instrucciones recomendadas por el proveedor del fotocontrol respecto de su proximidad a las fuentes de iluminaci...

Page 12: ...tornillador Philips 1 Afloje y extraiga los 4 tornillos de cabeza Philips 10 24 existentes en la parte frontal de la luminaria 2 Alinee los 4 espaciadores de 7 8 con los orificios existentes 3 Utilice...

Page 13: ...Todas las marcas comerciales son propiedad de sus respectivos propietarios Product availability specifications and compliances are subject to change without notice La disponibilit du produit les sp ci...

Reviews: