For Sales and Support, Contact Walker EMD • Toll-free: (800) 876-4444 • Tel: (203) 426-7700 • Fax: (203) 426-7800 • www.walkeremd.com
NFX9000 Adjustable Frequency Drives
3-2
For more information visit:
www.EatonElectrical.com
MN04002003E
February 2006
Table 3-2: Group 1 — Basic Parameters
The parameter may be set during operation.
Code
Parameter
Min.
Max.
Unit
Default
Cust
Note
1-00
Maximum operation
frequency
50.0
400
Hz
60.0
50.0 – 400 Hz
1-01
Maximum voltage
frequency
10.0
400
Hz
60.0
10.0 – 400 Hz
1-02
Maximum output
voltage
2.0
255
V
220
2.0 – 255V
1-03
Mid-point frequency
1.0
400
Hz
1.0
1.0 – 400 Hz
1-04
Mid-point voltage
2.0
255
V
12.0
2.0 – 255V
1-05
Minimum output
frequency
1.0
60.0
Hz
1.0
1.0 – 60 Hz
1-06
Minimum output
voltage
2.0
255
V
12.0
2.0 – 255V
1-07
Upper bound of
frequency
1
110
%
100
1 – 110%
1-08
Lower bound of
frequency
0
100
%
0
0 – 100%
1-09
Acceleration time 1
(Tacc1)
0.1
600
sec.
10.0
0.1 – 600 seconds
1-10
Deceleration time 1
(Tdec1)
0.1
600
sec.
10.0
0.1 – 600 seconds
1-11
Acceleration time 2
0.1
600
sec.
10.0
0.1 – 600 seconds
1-12
Deceleration time 2
0.1
600
sec.
10.0
0.1 – 600 seconds
1-13
JOG acceleration time 0.1
600
sec.
10.0
0.1 – 600 seconds
1-14
JOG deceleration
time
0.0
600
sec.
10.0
0.0 – 600 seconds
1-15
JOG frequency
1.0
400
Hz
6.0
1.0 – 400 Hz
1-16
Auto acceleration/
deceleration
0
5
0
0:
Linear accel./decel.
1:
Auto accel., linear decel.
2:
Linear accel., auto decel.
3:
Auto accel./decel.
4:
Linear accel., auto decel. (stall
prevention during deceleration
5:
Auto accel./decel. (stall
prevention during deceleration)
1-17
S-curve setting in
acceleration
0
7
0
0 – 7
1-18
S-curve setting in
deceleration
0
7
0
0 – 7