Menvier40/100 

Installation 

Page 21 

 

Louder 

Note: This control changes the 
volume of non-alarm tones (for 
example Exit/Entry tone). The 
volume of alarm tones is fixed. 

Softer 

Engineering Keypad 

An Engineering Keypad is a modified i-kp01 that 
can be plugged into a dedicated connector on the 
control unit PCB (see item 4 in Figure 3) or any of 
the expanders (see 13 in Figure 15 or 10 in Figure 
17). An Engineering Keypad does not need to be 
addressed, and will always be recognised by the 
control unit as an Engineering Keypad. 

You can use an Engineering Keypad to program 
the system without being tied to any of the 
installed keypads. If you wish to move an 
Engineering keypad from one connection point to 
another then you can do so without removing 
power from the system. 

Step 4. Fit and Connect 
Expanders 

Both wired and radio expanders are supplied in 
the same plastic case.  

Mark the position of at least three fixing holes. 
Break out the required cable entries, see Figures 
15 17. 

Use M4 25mm countersunk screws in all three 
fixing holes when mounting the back of the case 
on the wall. 

Note that radio expanders are not approved for 
Security Grade 3 systems. 

Connecting an Expander to the Bus 

Both wired and radio expanders provide a 
connector for the bus at the bottom of their PCBs 
(item 13 in Figure 15 and 11 in Figure 17). 

 

Figure 33 Wiring Expanders 

Addressing Expanders 

The control unit assigns addresses to all devices 
connected to the bus cable. You must start this 
process off from the Installer Menu, during the 
initial power up. See page 29 for instructions. 

Expander Loudspeakers 

During normal operation loudspeakers on 
expanders repeat setting and entry tones for the 
ward that the expander is allocated to. During an 
alarm the loudspeakers repeat alarm tones.  

Each loudspeaker draws up to 280mA in 
operation. if there is more than one expander 
loudspeaker then the bus may not be able to 
supply sufficient current during an alarm. 

Note that you must enable entry exit tones from 
the expander loudspeakers from Installer Menu. 

Step 5. Connect Control Unit 
to Mains 

WARNING:

 ENSURE THAT THE MAINS 

SUPPLY IS DISCONNECTED AND ISOLATED 
BEFORE MAKING ANY MAINS CONNECTIONS. 
All mains electrical connections must be carried 
out by a qualified electrician and must comply with 
the current local regulations (e.g. IEE). 

Mains Cabling 

Note: To avoid mains interference, the mains 
cable must enter the control unit through its own 
cable entry hole (7 in Fig 2) and must not be 
mixed with other cables. 

Mains Connection 

Figure 34 shows the mains connection. Connect 
to a suitable supply using a double pole 
disconnect (isolation) device in accordance with 
EN60950-1. 

Caution:

 

Do not apply power at this point.

 

Anchor the mains cable with a strain-relief tie. 
There is a eye located near the mains cable entry 
hole for this purpose. 

L

N

 T250mA 250V

230V ~50Hz 170mA

 

Figure 34 Mains Connection 

Summary of Contents for menvier40

Page 1: ...Menvier40 Menvier100 Security System Installation Guide Issue 3...

Page 2: ...by the words Note Caution or WARNING Note Describes conditions that may affect the proper functioning of the equipment but will not damage the equipment Caution Describes actions that will physically...

Page 3: ...6 Connect Wired Zones 22 Four Wire Closed Circuit Connections 22 Two Wire Closed Circuit Connections 22 Fully Supervised Loop Connections 22 Step 7 Connect Wired Outputs 24 Control Unit Wired Outputs...

Page 4: ...Menvier40 100 Page iv This page is intentionally blank...

Page 5: ...and an external prox reader KEY EP A range of wireless peripherals is available for operation with the wireless expanders These include a door contact universal transmitter a passive infra red detect...

Page 6: ...etting the time and date is a user function If you wish you can also program the system from a PC or laptop connected to the Ethernet port on the control unit PCB The control unit contains a web page...

Page 7: ...ll affect the signal from a transmitter Please read Eaton s Security Business publication Guidance Notes for Wireless Alarm System Installations obtainable from www coopersecurity co uk for more infor...

Page 8: ...conducting films These glasses are particularly poor at transmitting radio waves Guided Tour CAUTION All printed circuit boards for the control unit its expanders and keypads have been tested for Ele...

Page 9: ...Control Unit 1 PSTN Connector for on board communicator 2 Lid tamper connector 3 RS485 terminator 4 Engineering keypad connector 5 USB socket Mini B 6 Heartbeat LED 7 Zone output and Aux power connec...

Page 10: ...Page 6 1 Bus cable connector 2 Aux power 3 Wired zone connectors 4 Aux power 5 Outputs relay and transistorised 6 12V Siren Bell supply 7 Siren strobe and TR 8 Auxiliary tamper 9 Loudspeaker Figure 4...

Page 11: ...e B ACE fixed To open the keypad first gently prise off the trim on the front and remove the two screws Next carefully lever the front of the keypad containing the PCB and display away from the keypad...

Page 12: ...ont You may need to gently push the bottom edge of the caps in with the end of a small screwdriver to start them Remove the two screws hidden underneath see Figure 9 Gently swing the lower side of the...

Page 13: ...XT READER Z1 Z2 OP 1 6a 6b 3 4 5 6 2 1 Tamper switch 2 Sounder 3 Connector for KEY EP Terminals for zones 4 Sounder volume control 5 Connector for control unit data bus and output terminal 6 Jumpers f...

Page 14: ...ne connectors 16 Bus address display 17 Aux power 18 Loudspeaker connectors 19 Outputs Figure 15 EXP W10 Wired Expander 1 1 2 3 1 8 7 5 6 4 10 9 11 12 13 10 1 16 15 14 1 17 18 19 1 Cable entry also be...

Page 15: ...3 Central keyhole 4 PCB 5 Link to enable disable front rear tamper switch 6 Lid tamper rear tamper behind PCB 7 Bus termination jumper 8 Addressing button 9 Fixing holes 10 Engineering keypad connect...

Page 16: ...the overall calculation CAUTION Ensure that the system does not demand more than the maximum current available from the control unit during an alarm see page 38 Bus Cabling Requirements Cable Type In...

Page 17: ...are only two arms on the star then this is the same as a daisy chain configuration see Daisy Chain 1 in Figure 18 If required fit the termination jumper at the devices on the end of each arm If there...

Page 18: ...0 74V 1 47V 2 21V 2 94V 3 68V 4 42V 5 15V 5 89V 6 62V 7 36V 480mA 0 79V 1 54V 2 30V 3 07V 3 84V 4 61V 5 38V 6 14V 6 91V 7 68V 500mA 0 80V 1 60V 2 40V 3 20V 4 00V 4 80V 5 60V 6 40V 7 20V 8 00V 520mA 0...

Page 19: ...the wall There must be enough space around this point to fit the supplied tamper shroud see Figure 21 Fitting Plastic Feet and Tamper Sleeve The control unit is supplied from the factory with four pl...

Page 20: ...20Vac connector on the PCB 11 in Figure 3 Installing the Lid Back Tamper Figure 25 Lid Back Tamper Fit combined lid back tamper bracket and switch provided Ensure that the switch is oriented as shown...

Page 21: ...riate plastic sections Use 4mm x 25mm countersunk screws with a thread suitable for the wall material in at least three fixing holes when mounting the back of the keypad on the wall i KP01 For i KP01...

Page 22: ...ith EN50131 1 2006 at Grade 3 disable the ABCD LEDs Backlight Control for KEY K01 KP01 KPZ01 You can control the brightness of the keypad backlights by fitting links over the BRIGHT jumper on the keyp...

Page 23: ...e following Status OK LED ON MENU STATUS OK LED Status OK LED OFF The green status LED under the navigation key will glow for 20 seconds after the last press this may be useful when the keypad is plac...

Page 24: ...the single retaining screw 2 Tilt the edge of the fixing plate and then slide it a short distance parallel to the body of the prox reader 3 Slide the fixing plate away from the reader body along the c...

Page 25: ...g Expanders Addressing Expanders The control unit assigns addresses to all devices connected to the bus cable You must start this process off from the Installer Menu during the initial power up See pa...

Page 26: ...he wiring for CCL zones on the EXP WCC wired expander Note that the EXP WCC provides connectors for a total of ten separate 4 wire CCL detectors and that there are separate terminals for both alarm an...

Page 27: ...ed Expander 4K7 Alarmcontacts Tamper contacts 2K2 EOL 4K7 Alarmcontacts Tamper contacts 100 Ohms Figure 41 FSL Zone Wiring EXP WCC The allowed values for Alarm Contact End of Line are the same as for...

Page 28: ...methods of connection Figure 46 shows an example of a general method of using the outputs to connect a wired sounder It is possible to program the TR terminal on the control unit see item 7 in Figure...

Page 29: ...on at the expander FSL wiring Connect TR to the left terminal of a zone connector see Figure 49 The left hand terminal is the one next to the Z on the terminal label The maximum length of wire is 50m...

Page 30: ...e Line Fault Response selected in the Installer Menu Test Calls The control unit can be programmed to make test report calls to an ARC Static test calls can be programmed to occur at set times or inte...

Page 31: ...ting a line in the UK The internal communicator must be connected to the telephone network by a If the wiring is owned by British Telecom British Telecom b If the wiring is not owned by British Teleco...

Page 32: ...using a dual path communicator 3 Plug the Communication Wiring Harness onto the communications connector on the main PCB If the system has already been installed 4 Re connect the battery 5 Fit the ca...

Page 33: ...control unit PCB item 6 in Figure 3 starts flashing The navigation keys on any attached keypad start flashing All connected keypads briefly show the software revision of the keypad itself followed by...

Page 34: ...u should leave the Installer Menu to save the changes you have made see below Diagnostic LED on Expanders You may notice the DIAGNOSTIC LED flashing on an expander PCB The LED gives one two three or f...

Page 35: ...including radio HUDs fire alarm zones 24 hour zones and tampers are disabled Note that this does not apply if you are using the web browser interface from a PC If you have logged into the system from...

Page 36: ...ould now glow green Note The log is protected and cannot be erased by the Installer Restoring Factory Defaults Only If you wish to restore all factory default options without defaulting the user and i...

Page 37: ...f any other peripherals Program the System Program the system to suit user requirements Page 34 is a summary of the Installer Menu on the control unit Please see the Menvier40 100 300 Engineering Guid...

Page 38: ...ctive Quick set Quick omit User code reqd 2 Way Replies 2 Way Set Instant Duress Enable User reset Zone alarms 6 Zone tampers System tampers Confirmation Confirmation Mode Basic DD243 BS8243 Confirmat...

Page 39: ...c Test call disabled 16 Appears only when Dynamic Test call is disabled 17 Appears only when Report Type Fast Format and Confirmation Mode Basic 18 Shows None if no module fitted 19 Must be activated...

Page 40: ...ish to find the location of any keypad or expander you can employ the Test Locate Bus Device option in the Installer Menu Use this option to make a selected bus device give a continuous tone from its...

Page 41: ...an connect any combination of these devices to the bus Capacities Menvier100 Zones 100 max with expanders Outputs 100 max with expanders Expanders and Wired Keypads 45 max devices see note Radio Keypa...

Page 42: ...may have its own power supply For Security Grade 2 the required battery standby time is 12 hours However the total average current available over 12 hours from the 17Ah battery is limited by the powe...

Page 43: ...868 6625MHz Narrowband EN 300 220 3 EN 300 330 2 Transmitter range The range of the transmitters compatible with this control unit depends on the environment in which they are installed As a guideline...

Page 44: ...pad with internal prox reader but without zones or external prox reader key ep External prox reader for KEY KPZ01 KP01 KEY K01 keypad KEY KP01 keypad with internal prox reader and terminals for extern...

Reviews: