Parameters
04/10 MN04020001Z-EN
92
PNU
ID
Access right
RUN
Value
Description
Factory setting
(P1.3)
P6.15
184
/
Frequency reference value REF
0.00
-P6.4 - 0.00 - P6.4 Hz
The setpoint value (REF) defined here can be activated at
parameter P6.2 and via the keypad (LOC/REM).
In KEYPAD mode, the value can be changed with the arrow
buttons. The changes are written back automatically to this
parameter (P6.15).
P6.16
1474
/
Stop key
1
In the default settings, the STOP button of the keypad is active in
all operating modes.
The Stop function can be set at parameter P6.8.
0
Deactivated
Stop executed only via control signal terminals (I/O) or fieldbus
(BUS).
Switching the LOC/REM button to KEYPAD removes the block on
the STOP button function set here.
Note:
This does not deactivate the Reset function (FS loading with
5 s actuation of the STOP button).
1
Activated
P6.17
1427
-
Control place 2
3
Assignment of the control levels as at P6.1.
Control level 2 is activated via parameter P3.25.
P6.18
1428
-
Setpoint Source 2
2
Assignment of setpoint sources as at P6.2.
Setpoint source 2 is activated via parameter P3.26.
P6.19
502
/
Second acceleration time (acc2)
10.0
0.1 - 3000 s (see P6.5).
The activation is executed via parameter P3.15.
P6.20
503
/
Second deceleration time (dec2)
10.0
0.1 - 3000 s (see P6.6).
The activation is executed via parameter P3.15.
P6.21
526
-
Transition frequency (acc1 - acc2)
0.00
0.00 - P6.4 Hz
0.00 Hz = deactivated
If the output frequency set here is exceeded, the acceleration time
is switched automatically from acc1 (P6.5) to acc2 (P6.19).
P6.22
1334
-
Transition frequency (dec1 - dec2)
0.00
0.00 - P6.4 Hz
0.00 Hz = deactivated
If the output frequency set here is exceeded, the deceleration time
is switched automatically from dec1 (P6.6) to dec2 (P6.20).
P6.23
1429
-
REV blocked
0
The rotating field reversal of the output frequency is blocked.
0
Deactivated
1