3
EATON
IB500012EN
Installation instructions
Installation Instructions – LuxeScape Collection Accessories
Tenon Sleeve
PN: ARPA2
(3) Set Screws
ote:
N
Appropriate wall anchors are to be selected by
installer for the wall materials of construction.
Appropriate anchors must be able to withstand the
minimum torque defined for the mounting bolts.
Minimum torque defined is required to secure
accessory with luminaire to the wall. Torque may be
adjusted to a greater value if it is appropriate for the
selected anchors. Friction between bolts and anchors
must be considered. Anchors that will not withstand
the specified torque, are not appropriate for installing
the wall mount arm accessory.
2. Extend supply wires from junction box to minimum 3
feet in length.
3. Pull extended supply wires through arm and hook the
arm over installed wall mount plate.
4. Secure the arm by tightening the set screw on bottom
to 200 in-lbs against the wall mount plate.
5. Use installation instructions provided with luminaire to
mount fixture onto the arm.
WARNING: Recheck to be sure that the fixture has been
wired properly before energizing. Improper wiring may
result in driver failure which voids all warranties.
Photocontrol Orientation (If Equipped)
ote:
N
The orientation procedure is only required for
photocontrols which specifically require the cell
to be aimed north. Otherwise, factory orientation
will function properly. Follow the directions
recommended by the photocontrol supplier for
proximity to light sources. Lighted signs, building
surface reflection, floodlights, tree branches, etc.
may affect final position of the photocontrol.
1. Loosen the two (2) screws to allow rotation of the
receptacle. (Figure 5.)
2. Insert screwdriver into center slot and rotate receptacle
until indicator arrow points north.
3. Retighten screws.
4. Insert photoelectric control (or shorting cap) in
receptacle and twist into locking position.
ote:
N
The photocontrol (not included) must contain a soft,
resilient gasket fastened to the bottom surface to
assure a proper weather seal between the control
and the receptacle.
Tenon Sleeve Installation (2-3/8” Tenon Only)
Tools Required
3/16” hex bit, Torque wrench that measures up to 200 in-lbs
minimum.
1. Slide tenon sleeve
ARPA2
over 2-3/8” tenon. (Figure 6.)
Figure 5.
Figure 6.
Figure 7.
2. Install three, 3/8-16 UNC set screws into tenon sleeve
by hand. (Figure 7.)
3. Tighten all three 3/8-16 UNC set screws to 180 in-lbs.
(Figure 7.)
4. In the same order as step 3, torque all 3 setscrews to
200 in-lbs.