Remote Functions

KEYLOCK Function (SET Button Block)

If during sensor power-up the SYNC wire is connected to +V DC for at least one second, the keylock function will be activated and buttons will no longer be active.

After the first second, the SYNC input is available for the normal operating modes.

To deactivate the keylock, the sensor has to be turned off and re-powered with the SYNC wire not connected or ground connected (GND).

SYNC Input

The status of the SYNC input can determine the beginning and end of color identification. The sensor operates normally with all outputs functional with the

SYNC input disconnected (or connected to 0 V). When you c24 V to the SYNC input, the sensor outputs are disabled and color sensing stops (after the time

delay shown in the drawing at left). This may be useful with a multi-colored target where the color to detect is in a specific position, while other zones should be ignored.

RS485 Serial Connection (Only For E75-CLRMKRS-M12)

Complete sensor remote control is possible using the RS485 line. All functions, such as channel, tolerance and operating mode selection, can be accessed via

the serial connection. The serial communication parameters are as follows: 9600 baud, no equity, 8 data bits, 1 stop bit. All commands have to be sent via terminal

in an ASCII format as follows:

Received Channel Status

At any moment, the receipt of the

‘r <CR> <LF>’

command indicates the sensor configuration.

Remote Setting Mode

To access the remote setting mode, the SYNC input must remain passive for at least 300 ms. The commands available are:

@ <CR> <LF>

Beginning of the remote setting (together with passive SYNC)

cx <CR> <LF>

Channel selection, with x {1,2,3}

tx <CR> <LF>

Tolerance selection, with x {0,1,2,3,4,5,6,7,8,9}

mx <CR> <LF>

Operating mode selection, with x {1,2}

m1 = C

m2 = C+1

e <CR> <LF>

Configuration sequence activation

q <CR> <LF>

Exit from remote setting mode without saving configuration

If the SYNC input is activated before the

‘e’

(execute) command is given, the sensor exits the remote setting mode without saving the configuration,

similar to the

‘q’

(quit) command.

If the SYNC input is active at the receipt of the

‘@ <CR> <LF>’

command, the sensor responds with: ‘

?? <CR> <LF>.’

At the receipt of the

‘q <CR> <LF>’

or

‘e <CR> <LF>’

commands, the sensor transmits

‘ok <CR> <LF>.’

The

‘lo <CR> <LF>’

message is transmitted if the signal is too low and

‘hi <CR> <LF>’

if the signal is too high.

Delay Configuration

To access the delay configuration, the SYNC input has to remain passive for at least 300 ms. The commands available are:

@ <CR> <LF>

Beginning of the delay configuration (together with passive SYNC)

dx <CR> <LF>

Delay selection, with x {0,1,2,3,4,5}

d0 = 0 ms

d3 = 20 ms

d1 = 5 ms

d4 = 30 ms

d2 = 10 ms

d5 = 40 ms

e <CR> <LF>

Memorization of the new delay

q <CR> <LF>

Exit from the delay configuration without saving

If the SYNC input is active at the receipt of the

‘@ <CR> <LF>’

command, the sensor responds with:

‘?? <CR> <LF>.’

At the receipt of the

‘q <CR> <LF>’

or

‘e <CR> <LF>’

commands, the sensor transmits:

‘ok <CR> <LF>.’

SYNC

24 V

Output Disable signal

0 V (or Open)

Output Enable signal

OUTPUT

ON

OFF

≦ 335 μs

≦ 170 μs

During the command transmission, single strings have to follow each other with a delay of at least 1 ms.

Summary of Contents for IntelliView E76 Series

Page 1: ...ерации ت ت ﻮ ﻮ ـ ـ ـ ـ ﻣ ﻣ ﺮ ﺮ ـ ـ ـ ـ ﻄ ﻄ ﺧ ﺧ ﻲ ﻲ ﺋ ﺋ ﺎ ﺎ ـ ـ ـ ـ ﺑ ﺑ ﺮ ﺮ ﻬ ﻬ ﻛ ﻛ ر ر ﺎ ﺎ ـ ـ ـ ـ ﻴ ﻴ ﺗ ﺗ ﺮ ﺮ ﻳ ﻳ ﺬ ﺬ ـ ـ ـ ـ ﺤ ﺤ ﺗ ﺗ ــــﺐ ـ اﻟﺘﺮﻛﻴ و ــــﻴﺎﻧﺔ ـ اﻟﺼ ــــﺎل ـ اﻋﻤ ــــﻢ ـ ﺗﺘ ﻻ اﻟﻤــــﺪرﺑﻴﻦ اﻟﻌــــﺎﻣﻠﻴﻦ ﻗﺒــــﻞ ﻣــــﻦ اﻻ en de fr es it zh ru ar 03 22 IL05305009Z P52078 Instruction Leaflet Montageanweisung Notice d installation Instrucciones de montaje Istruzioni per il montaggio 安 ...

Page 2: ... the simple setup procedure Initial Setup SEL Button This button allows you to scroll through sensor settings Initial Setup Tecla SEL Esta tecla permite hojear por los ajustes de los sensores primera instalación 4 3 5 6 8 7 1 2 0 V BU V V BN SYNC INPUT RD OUTPUT 1 OUTPUT 2 0 V OUTPUT 3 GN YE GY Load Load Load 4 3 5 6 8 7 1 2 0 V BU V V BN SYNC INPUT RD OUTPUT 1 OUTPUT 2 0 V OUTPUT 3 Load Load Load...

Page 3: ...e shown in a cyclical manner and the delay value will be stored The delay value setting is common for all three outputs When a delay value other than zero is set the outputs will be maintained active for a minimum time equal to the number of milliseconds visualized on the display i e d 00 0 ms d 05 5 ms d 10 10 ms Channel Status Visualization This function provides adjustment for all three sensor ...

Page 4: ...l communication parameters are as follows 9600 baud no equity 8 data bits 1 stop bit All commands have to be sent via terminal in an ASCII format as follows Received Channel Status At any moment the receipt of the r CR LF command indicates the sensor configuration Remote Setting Mode To access the remote setting mode the SYNC input must remain passive for at least 300 ms The commands available are...