background image

 

ELC-GP02 may connect to ELC using cable ELC-CBPCELC3

 

8 PIN MINI DIN

9  PIN D-SUB female

PC/HMI COM Port

ELC COM1 Port

Rx       2

GND

1

2

3

4

5

6

7

8

Rx 

GND

 

IL05003005E.pdf 

6

COMMUNICATION CONNECTION

 

ELC-GP02 may connect to a PC by using cable ELC-CBPCGP3

 

ELC-CBPCGP3

1

5

6

9

9 PIN D-SUB

ON PC (RS-232)

ON ELC-GP02/04

5

1

9

6

9 PIN D-SUB

   

9  PIN D-SUB female

 

 

RS-232: 

3       Tx 

5       GND

RS-232  9  PIN D-SUB male

 

PC  COM Port

9  PIN D-SUB female

Rx        2

GND    5

3       Tx 

5       GND

    5V

ITEM 

ELC-GP02 

Display Range 

72 mm (W) X 22 mm (H) 

Contrast Adjustment 

15-step contrast adjustment   

Language Font 

ASCII: characters 

Other: user define 

Font Size (ASCII) 

5 X 8, 8 X 8, 8 X 12, 8 X 16 

ALARM Indication LED 

1. Power on indication (Flash three times) 

2. Flash for communication error or other alarm   

  3. Special Indication by user programming   

RS-232 Indication LED 

Flashing when communicating by using RS-232. 

RS-485 Indication LED 

It will be flashing when communicating by using RS-485. 

Program Memory 

256KB flash memory 

Ext

ernal

 In

ter

fa

ce

 

Serial Communication Port 

RS-232 (COM1) 

RS-232 

Data length: 7 or 8 bits 

Stop bits: 1or 2 bits 

Parity: None/Odd/Even 

Transmission speed: 4800bps~115200bps 

RS-232: 9 PIN D-SUB male 

Extension Communication 

Port 

RS-485 (COM2) 

RS-485 

Data length: 7 or 8 bits 

Stop bits: 1 or 2 bits 

Parity: None/Odd/Even 

Transmission speed: 4800bps~115200bps 

RS-485: 5-Pin Removal Terminal 

Extension Slot 

The slot for program copy card 

5-Pin Removal Terminal 

There are DC 24V input and RS-485 input 

 

3  

TRANSFER MODULE 

The function of program copy card that ELC-GP02 provides to copy user program, system function 
and passwords is different from the copy program. It is used to copy the whole HMI environment 
settings and application programs to another HMI rapidly. It can save much time and manpower. The 
operation is in the following.     

Definition: ELC-GPXFERMOD = XMOD, GP Series = GP

 

Step 

GP

Æ

XMOD 

XMOD

Æ

GP 

Turn the switch on the XMOD to GP

Æ

XMOD 

Turn the switch on the XMOD to XMOD

Æ

GP 

Insert the XMOD into the extension slot of GP 

Insert the XMOD into the extension slot of GP 

Input the power to GP 

Input the power to GP 

It will display “remove XMOD” on the screen and 

power on again 

It will display “remove XMOD” on the screen and 

power on again 

HMI display message 

Copy HMI program to XMOD (GP

Æ

XMOD) 

Copy XMOD program to HMI (XMOD

Æ

GP) 

If the model type of GP does not correspond with the 

model type of program of XMOD, GP will display “GP 

series and XMOD is different. Press Enter to Confirm 

GP series

Æ

XMOD. Press Esc to Exit”. 

If there is no program in XMOD, GP will display “The 

XMOD is Empty. XMOD

Æ

GP series is illegal”. 

GP will display “GP 

Æ

XMOD series Please wait!” 

during transmission. 

GP will display “GP 

Æ

XMOD series Please wait!” during 

transmission. 

GP will display “Please Remove the XMOD and 

Reboot” when completing transmitting. 

GP will display “Please Remove the XMOD and Reboot” 

when completing transmitting. 

 

4  

PASSWORD FUNCTION 

1  If the password is forgotten, the password may be cleared using the following code: 

8888

. This 

universal code will clear the password and all internal programs of ELC-GP02. The ELC-GP02 
will be re-set to the factory settings.   

2  Users may use 0~9 and A~Z as characters for the password. Users must use the function keys 

F0~F4 to input the password characters. 

F0: scrolls in a loop as follows 0 

Æ

 A 

Æ

 B 

Æ

 C 

Æ

 D 

Æ

 E 

Æ

 F 

Æ

 0 

F1: scrolls in a loop as follows 1 

Æ

 G 

Æ

 H 

Æ

 I 

Æ

 J 

Æ

 K 

Æ

 1 

F2: scrolls in a loop as follows 2 

Æ

 L 

Æ

 M 

Æ

 N 

Æ

 O 

Æ

 P 

Æ

 2 

F3: scrolls in a loop as follows 3 

Æ

 Q 

Æ

 R 

Æ

 S 

Æ

 T 

Æ

 U 

Æ

 V 

Æ

F4: scrolls in a loop as follows 4 

Æ

 W 

Æ

 X 

Æ

Æ

 Z 

Æ

 4 

F5: it just can be used to be constant 5. 

F6: it just can be used to be constant 6. 

F7: it just can be used to be constant 7. 

F8: it just can be used to be constant 8. 

F9: it just can be used to be constant 9. 

5  

HARDWARE OPERATION

The steps to Startup the ELC-GP02: 

1  Apply 24V DC power, 

2  Enter into the startup display, 

3  Enter the user-designed program,   

4  Press Esc key and hold on for 5 seconds to return to system menu. 

There are five selections in the system menu and are described below. 

SELECTIONS 

EXPLANATION 

Download 

Program 

Use the connection cable (ELC-CBPCTP3) to connect the serial communication port RS-232 

of ELC-GP02 to a PC.    Then use the ELCSoftGP software to download an application 

program to the ELC-GP02. 

Upload Program 

Use the connection cable (ELC-CBPCTP3) to connect the serial communication port RS-232 

of ELC-GP02 to a PC.    Then use the ELCSoftGP software to upload an application program 

from the ELC-GP02. 

Copy Program 

Transfer a program between two ELC-GP02 units. 

1: transmit programs 

2: receive programs 

When transmitting programs and data between two ELC-GP02 unit.    Set one ELC-GP02 to 

“Receive Program” mode and the other ELC-GP02 to “Transmit Program” mode. Please use 

twisted pair wires to connect the two units via the RS-485 ports.     

GP02 Settings 

Used to modify the ELC-GP02 system settings. There are 8 items that may be modified. 

1.  Communication protocol: Set the address of ELC-GP02 and the communication string for 

either RS-232 or RS-485. 

2. Contrast: 

Adjust 

the 

contrast of LCM display screen. 

3.  Back-light: adjust the automatic turn off time of LCM. Setting range is 00~99 seconds. If 

set to 00, the LCM Back-light will not turn off. 

4.  Buzzer: Used to set the buzzer sound, normal mode or quiet mode. 

5.  Language Setting: Used to set the displayed language. English, Traditional Chinese, 

simplified Chinese or user defined language. 

6.  Password setting: Used to set, enable, and disable the password function.    If the 

password function is enabled, it will require the user to input a password before the 

system menu may be accessed. The factory password is 1234. 

7.  Startup display: Used to select the ELC-GP02 startup display. 

8.  Comm. Indicator : Used to select the communication Indicator enable or disable. 

ELC Connection 

There are two methods to connect to ELC: 

1.  Use the connection cable (ELC-CBPCELC3) to connect program communication I/O 

RS-232C of ELC to serial communication port (COM1) RS-232 of ELC-GP02. 

2.  Use twisted cable to connect RS-485 of ELC to extension communication port (COM2) 

RS-485. 

Execution 

Execute the internal program that download from ELCSoftGP or transmitted from other 

ELC-GP02 units. When entering execution program, you can return to system menu by 

pressing Escape/Exit (Esc) key for 5 seconds. 

 

1

4

6

7

8

1,2

 

The Pin definition of 9 PIN D-SUB 

4