5 Appendix
5.3 Technical Data
20
easy800-BLT-ADP Bluetooth adapter
07/12 MN04902002Z-EN
www.eaton.com
5.3 Technical Data
5.3.1 Standards
5.3.2 General ambient conditions
easy800-BLT-ADP
Standards
EN 55011, EN 50178, IEC EN 61000-4, IEC60068-2-6,
IEC60068-2-27
Ambient climatic conditions
Cold to IEC 60068-2-1, heat to IEC 60068-2-2, damp heat,
constant, to IEC 60068-2-78; cyclical to IEC 60068-2-30,
temperature change to IEC68000-2-14
Operating ambient temperature
°C, (°F)
-25 - +55 (-13 - +131)
Condensation
Prevent condensation by means of suitable measures
Storage
°C, (°F)
-40 - +70, (-40 - +158)
Relative humidity, non-condensing
(IEC/EN 60068-2-30)
%
5 - 95
Air pressure (in operation)
hPa
795 - 1080
Ambient mechanical conditions
Degree of protection EN 50178,
IEC 60529, VBG4
IP20
Vibrations (IEC EN 60068-2-6)
Constant amplitude 3.5 mm
Hz
5 - 8.4
Constant acceleration, 1 g
Hz
8.4 - 150
Mechanical shock resistance
(IEC EN 60068-2-27) semi-sinusoidal
15 g/11 ms
Shocks
18
Drop (IEC EN 60068-2-31),
drop height
mm
50
free fall, packaged
(IEC EN 60068-2-32)
m
0.3
Electromagnetic compatibility (EMC)
Electrostatic discharge (ESD),
to IEC EN 61000-4-3
Air discharge
kV
8
Contact discharge
kV
6
Electromagnetic fields (RFI),
to IEC EN 61000-4-3
0.8 - 1.0 GHz
V/m
10
1.4 - 2 GHz
V/m
3
2.0 - 2.7 GHz
V/m
1
Radio interference suppression
EN 55011 Class B