Error Messages
Failure code
[hex]
Value shown on
display
Meaning
00
no-fit
Stop, ready for operation
01
OI-b
Braking chopper overcurrent
02
OL-br
Braking resistance overload
03
O-l
• Overcurrent at variable frequency drive output
• Motor overload
• Overtemperature on variable frequency drive (heat sink)
04
I.t-trp
Motor, thermal overload
05
SAFE -1
Short-circuit at safety circuit input
06
O Volts
Overvoltage (DC link)
07
V-volts
Undervoltage (DC link)
08
O-t
Overtemperature (heat sink)
09
V-t
Undertemperature (heat sink)
0A
P-dEf
Default settings, parameters have been loaded
0B
E-trip
External error message
0C
SC-ObS
Error, OP bus
0D
FLt-dc
Excessively large voltage waves in DC link
0E
P-LOSS
Phase failure (mains side)
0F
h O-I
Overcurrent at variable frequency drive output
10
th-Flt
Thermistor fault, internal (heat sink)
11
dAtA-F
EEPROM checksum fault
12
4-20F
Analog input:
• Out-of-range value
• Wire breakage (4 mA monitoring)
13
dAtA- E
Error in internal memory
14
V-dEF
User-definable factory parameters have been loaded
15
F-Ptc
Excessively high temperature, motor PTC
16
FAN-F
Fault, internal fan
17
O-hEAt
Excessively high ambient temperature
18
O-torq
Maximum torque limit exceeded
19
V-torq
Output torque too low
1A
Out-F
Fault at variable frequency drive output
1D
SAFE-2
Short-circuit at safety circuit input
1D
Enc-01
Encoder, communication lost
1F
Enc-02
Encoder, speed error
20
Enc-03
Encoder, wrong PPRs set
21
Enc-04
Encoder, channel A fault
22
Enc-05
Encoder, channel B fault
23
Enc-06
Encoder, channel A and B fault
24
Enc-07
Encoder, RS485 data channel error