15
AC WIRING/CONTACT INPUT WIRING
AC Power Input
(AC Models Only)
Neutral
Hot
AC Power In
10-15 VDC Input
+
DC Power Input
(DC Models Only)
Check part number on counter
label to verify correct voltage
rating.
57601-40X: 115 VAC
57602-40X: 230 VAC
57605-452: 24 VAC
1
12
2
3
4
5
6
7
8
9
10
11
13
14
15
16
17
18
19
20
21
22
1
12
2
3
4
5
6
7
8
9
10
11
13
14
15
16
17
18
19
20
21
22
To prevent multiple counts, use one
of the contact count modes. See
programming diagram.
All dip switches OFF.
Push button
limit switch,
relay contact,
etc.
Contact Count Input
1
12
2
3
4
5
6
7
8
9
10
11
13
14
15
16
17
18
19
20
21
22
Dotted lines indicate
which inputs may be
wired in this manner.
Typically a separate
sensor is used for each
input.
Control inputs
(terminals 15-18) may
be wired in the same
manner.
-
Use 1/2 amp slow blow fuse.
(Does not include external
transducer load.)
Check part number on counter
label to verify correct voltage
rating.
57600-40X: 10-15 VDC
Terminal 4 (Ground) and Terminals 2 and 3
(Com) are internally connected.
Fuse Size
AC Power In
115 V, 60 Hz
115 V, 50 Hz
230 V, 60 Hz
230 V, 50 Hz
24 V, 60 Hz
24 V, 50 Hz
U.S.
1/8 amp
1/4 amp
1/16 amp
1/8 amp
1 amp
1 amp
Use slow blow fuses for all voltages.
Terminal 4 (Ground) and
terminals 2 and 3 (Com) are
internally connected.