background image

DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY

The information, recommendations, descriptions and safety notations in this document are based on Eaton Corporation’s 

(“Eaton”) experience and judgment and may not cover all contingencies. If further information is required, an Eaton sales 

office should be consulted. Sale of the product shown in this literature is subject to the terms and conditions outlined in 

appropriate Eaton selling policies or other contractual agreement between Eaton and the purchaser.
THERE ARE NO UNDERSTANDINGS, AGREEMENTS, WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING 

WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, OTHER THAN THOSE 

SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES. ANY SUCH CONTRACT STATES THE 

ENTIRE OBLIGATION OF EATON. THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY 

ANY CONTRACT BETWEEN THE PARTIES. 
In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability or 

other-wise for any special, indirect, incidental or consequential damage or loss whatsoever, including but not limited to 

damage or loss of use of equipment, plant or power system, cost of capital, loss of power, additional expenses in the 

use of existing power facilities, or claims against the purchaser or user by its customers resulting from the use of the 

information, recommendations and descriptions contained herein. The information contained in this manual is subject to 

change without notice. 

ii

DT400/436 tee connector installation instructions

   MN650001EN   September 2014   www.cooperpower.com

Summary of Contents for DT400

Page 1: ...Lorem ipsum dolor sit Amat Connectors and Splices MN650001EN Effective September 2014 Supersedes IS550 30 1 March 2011 DT400 436 Tee Connector Installation Instructions...

Page 2: ...TING CONTRACT BETWEEN THE PARTIES ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES In no event...

Page 3: ...DUCT INFORMATION Introduction 1 Acceptance and Initial Inspection 1 Handling and Storage 1 Standards 1 INSTALLATION PROCEDURE Installation Instructions 2 iii DT400 436 tee connector installation instr...

Page 4: ...Safety information DANGER Hazardous voltage Contact with hazardous voltage will cause death or severe personal injury Follow all locally approved safety procedures when working around high and low vol...

Page 5: ...rocedures or process described nor provide directions for meeting every possible contingency during installation operation or maintenance For additional information contact your representative Accepta...

Page 6: ...re long enough to reach the earthing eye on the tee connector The cable will be cut to its final length in a later step 3 Remove 435 mm of the cable sheath 4 Fold the screen wires back over the sheath...

Page 7: ...per face is parallel to the face of the bushing 3 Crimp the connector starting at the shoulder as shown Rotate the crimping tool 90 for each successive crimp 4 Remove any inhibitor that may come out o...

Page 8: ...mm socket wrench Step 8 1 Clean and apply lubricant to the insulating plug and the tee connector interface 2 Insert the insulating plug into the connector and engage the threads of the clamping screw...

Page 9: ...24 kV Figure 9 Installation of cap CAUTION The apparatus bushing and tee connector should not support the weight of the cable Clamp the cable immediately below the cable screen adapter Failure to com...

Page 10: ...This page is intentionally left blank 6 DT400 436 tee connector installation instructions MN650001EN September 2014 www cooperpower com...

Page 11: ...This page is intentionally left blank 7 DT400 436 tee connector installation instructions MN650001EN September 2014 www cooperpower com...

Page 12: ...use these trademarks without the prior written consent of Eaton Eaton 1000 Eaton Boulevard Cleveland OH 44122 United States Eaton com Eaton s Cooper Power Systems Business 2300 Badger Drive Waukesha...