DEVICE CONFIGURATION

Before using the E50 limit switch, you must configure the
device’s baud rate and network address.  The baud rate
defaults to 125 kbaud, and the address defaults to 63.
Additional parameters you may wish to configure include the
on, off, and one-shot delay, and the operate mode.  After
connecting the device to the network, use NetView or
another configuration tool to configure device.

Network Address

After connecting the E50 to the network, use the Netview
configuration software (or other configuration software) to
configure the device.  Unless pre-configured, a new device
will have a default address of 63 at a baud rate of 125 Kbaud
when connected to the network.

     

CAUTION

Since all new DeviceNet devices are factory set to address
63, it is usually not a good idea to leave an address set at
63.  Two nodes at the same address will cause a network
fault!

Built into the Cutler-Hammer Netview configuration software
is a function to locate nodes by continually flashing the
Module/Network Status LED between green and red.  Once the
Netview configuration software is communicating to the E50,
the address and all other user configurable parameters can then
be programmed.  (See the Netview manual for specific informa-
tion on how to change attributes.)  A list of configurable
attributes can be found on page 5 of this manual.

Off-line Configuration
An E50 switch may be configured off-line by connecting it
directly to the configuration tool (PC with software or a
hand-held type tool) and following the instructions for on-
line configuration.  24 VDC must still be supplied to the
switch in order to configure it off-line.

WIRING CONSIDERATIONS

     

ATTENTION

THE DEVICENET CABLE IS NEC (UL) TYPE CL2
RATED.  THE CABLE IS NOT SUITABLE FOR USE IN
ENVIRONMENTS REQUIRING RESISTANCE TO
CERTAIN OILS AND CUTTING FLUIDS.  PLEASE
CONSULT FACTORY FOR CABLING OPTIONS FOR
THESE APPLICATIONS.

Red

Blue

Bare

Connector Version-Face View Male

Cable Version

DeviceNet

Sensor

Black

V+

4

2

3

1

5

V–

Drain

CAN_H

CAN_L

V+

V–

Drain

CAN_H

CAN_L

White

Summary of Contents for DeviceNet E50DNA

Page 1: ...y and longest life expect ancy for Industrial Limit Switches INSTALLATION WARNING DO NOT INSTALL OR PERFORM MAINTENANCE ON THIS DEVICE WHILE THE CONTROLLER IS ENERGIZED DEATH OR SEVERE PERSONAL INJURY...

Page 2: ...embly Push Operational Head OPERATING HEADS WOBBLE STICK These spring return top operated heads use different rod type operators to detect motion in any direction perpendicu lar to the operator The op...

Page 3: ...030 in 0 290 in 4 lbs 8 oz B E50DS3 0 200 in 0 130 in 0 320 in 5 lbs 5 lbs B E50DH1 0 040 in 0 020 in 0 280 in 4 lbs 8 oz C E50DT1 0 040 in 0 020 in 0 280 in 4 lbs 8 oz C E50DT2 0 040 in 0 020 in 0 2...

Page 4: ...er Netview configuration software is a function to locate nodes by continually flashing the Module Network Status LED between green and red Once the Netview configuration software is communicating to...

Page 5: ...n line but not allocated Green by a master Flashing Device has detected a recoverable fault or a connection Red is in the timed out state Solid Device has detected an unrecoverable fault or is in the...

Page 6: ...de Rotary Operator Top Pushbutton Side Push Operators Top Pushbutton Adjustable Side Pushbutton Maintained Top Pushbutton Adjustable Side Pushbutton Side Push Roller 1 1 1 Can accommodate both U S 29...

Page 7: ...Switch state represents the physical location of the limit switch Head Actuation Count increments each time the head is actuated When Head Actuation Count reaches 80 or 100 of the Max Head Actuation C...

Page 8: ...s UINT Timestamp UINT Test Object Class 199 C7HEX Instance 1 Attribute Attribute ID Access Power OK 5 Get LED Disable 6 Get Set SOFTWARE TIMING The E50 is not capable of responding to all DeviceNet me...

Reviews: