background image

111032  Rev --

Page 3

Effective 9/97

REPEAT ACCURACY

The type of operating head used on an assembled limit
switch determines repeat accuracy for the switch assembly.

Assembled limit switches, without rollers used on operating
heads or levers, have a repeat accuracy as listed in Table 1
only.

Assembled limit switches with rollers used on operating
heads or levers have a repeat accuracy determined as
follows: add the repeat accuracy tolerance of Table 1 for the
type of operating head used to the concentricity tolerance of
Table 2 for the type of roller used on the lever or operator.
The  combination of these two tolerances is the limit switch
repeat accuracy.

Operating Data —Nominal

Operating

Travel To

Travel To

Force To

Minimum

Temp.

Catalog

Operate

Reset

Total

Operate

Return

Range

No.

Contacts

Contacts

Travel

Contacts

Force

(See Table)

90°

3 in.-lbs.

4.5 in.-oz.

A

E50DR1

90°

3 in.-lbs.

4.5 in.-oz.

D

E50DR19

15°

90°

1.5 in.-lbs.

2.5 in.-oz.

A

E50DL1

50°

50°

90°

3 in.-lbs.

B

E50DM1

0.065 in.

0.030 in. 0.290 in.

4 lbs.

8 oz.

B

E50DS1

0.065 in.

0.030 in. 0.290 in.

4 lbs.

8 oz.

B

E50DS2

0.065 in.

0.030 in. 0.290 in.

4 lbs.

8 oz.

B

E50DS3

0.200 in.

0.130 in. 0.320 in.

5 lbs.

5 lbs.

B

E50DH1

0.040 in.

0.020 in. 0.280 in.

4 lbs.

8 oz.

C

E50DT1

0.040 in.

0.020 in. 0.280 in.

4 lbs.

8 oz.

C

E50DT2

0.040 in.

0.020 in. 0.280 in.

4 lbs.

8 oz.

C

E50DT3

10°

15°

2 in.-lbs.

2.4 in.-oz.

C

E50DW1

10°

15°

2 in.-lbs.

2.4 in.-oz.

C

E50DW2

Standard

Spring Return

Low Temperature

Spring Return

Low Force

Spring Return

Maintained

Two position

Pushbutton

Spring Return

Pushbutton Adjustable

Spring Return

Push Roller

Spring Return

Pushbutton

Maintained

Pushbutton

Spring Return

Pushbutton Adjustable

Spring Return

Push Roller

Spring Return

Standard

Spring

Duty

Return

Heavy

Duty

Description

Operating Heads

Side Rotary

Side Push

Top Push

Wobble Head

OPERATING HEAD DATA

TABLE 1

Operating Head

Repeat Accuracy 

1

Side Operated

Standard Construction

within 0.0012”

Low Operating Force

within 0.0024”

Two-Step

within 0.006”

Neutral Position

within 0.006”

Side Push

within  0.003”

Top Operated

Top Push

within 0.002”

1

 Measured along arc for 1-1/2” lever or measured along push operator axis.

TABLE 2

Type

Diameter

Width

Concentricity Tolerance

Lever Roller Type

Nylon

3/4”

5/16”

+/-0.002”

Metal

3/4”

5/16”

+/-0.001”

Nylon

3/4”

1”

+/-0.005”

Ball Brg.

11/16”

1/4”

+/-0.002”

Nylon

1-1/2”

9/32

+/-0.005”

Push Roller Type

Metal

7/16”

5/32”

+/-0.002”

Metal

3/4”

5/32”

+/-0.005”

Summary of Contents for DeviceNet E50DNA

Page 1: ...y and longest life expect ancy for Industrial Limit Switches INSTALLATION WARNING DO NOT INSTALL OR PERFORM MAINTENANCE ON THIS DEVICE WHILE THE CONTROLLER IS ENERGIZED DEATH OR SEVERE PERSONAL INJURY...

Page 2: ...embly Push Operational Head OPERATING HEADS WOBBLE STICK These spring return top operated heads use different rod type operators to detect motion in any direction perpendicu lar to the operator The op...

Page 3: ...030 in 0 290 in 4 lbs 8 oz B E50DS3 0 200 in 0 130 in 0 320 in 5 lbs 5 lbs B E50DH1 0 040 in 0 020 in 0 280 in 4 lbs 8 oz C E50DT1 0 040 in 0 020 in 0 280 in 4 lbs 8 oz C E50DT2 0 040 in 0 020 in 0 2...

Page 4: ...er Netview configuration software is a function to locate nodes by continually flashing the Module Network Status LED between green and red Once the Netview configuration software is communicating to...

Page 5: ...n line but not allocated Green by a master Flashing Device has detected a recoverable fault or a connection Red is in the timed out state Solid Device has detected an unrecoverable fault or is in the...

Page 6: ...de Rotary Operator Top Pushbutton Side Push Operators Top Pushbutton Adjustable Side Pushbutton Maintained Top Pushbutton Adjustable Side Pushbutton Side Push Roller 1 1 1 Can accommodate both U S 29...

Page 7: ...Switch state represents the physical location of the limit switch Head Actuation Count increments each time the head is actuated When Head Actuation Count reaches 80 or 100 of the Max Head Actuation C...

Page 8: ...s UINT Timestamp UINT Test Object Class 199 C7HEX Instance 1 Attribute Attribute ID Access Power OK 5 Get LED Disable 6 Get Set SOFTWARE TIMING The E50 is not capable of responding to all DeviceNet me...