MODELS COVERED BY THIS MANUAL

Catalog Number

Description

E50DNA

Solid State Switch Body
with 2-meter cable

E50DNAC

Solid State Switch Body
with 5-pin DeviceNet
micro-connector

DESCRIPTION

General Information

• Network Media - DeviceNet
• Protocol - DeviceNet  Rel 2.0
• Type - Group 2 Only Slave Device using Predefined

Master Slave Connection Set

• Bandwidth - 125, 250, 500 Kbaud

All E50 Limit Switches consist of two modular, interchange-
able plug-in components: operating head and a solid state
switch body. Operating heads (side rotary, top and side
push, and wobble stick) are mounted on top of the switch
body in any of four positions. All assembled limit switches are
rated NEMA 3, 3S, 4, 4X, 6, 6P and 13. Obtain renewal parts by
ordering the catalog number labeled on each of the two limit
switch components.

NEMA ICS 2-225 describes preferred installation recommenda-
tions which ensure greatest reliability and longest life expect-
ancy for Industrial Limit Switches.

INSTALLATION

     

WARNING

DO NOT INSTALL OR PERFORM MAINTENANCE ON THIS
DEVICE WHILE THE CONTROLLER IS ENERGIZED.  DEATH OR
SEVERE PERSONAL INJURY CAN RESULT FROM CONTACT
WITH ENERGIZED EQUIPMENT.  VERIFY THAT NO VOLTAGE IS
PRESENT BEFORE PROCEEDING WITH INSTALLATION OR
MAINTENANCE. 
  Only qualified persons, as defined in the
National Electric Code, who are familiar with the installation,
maintenance and operation of this device and the equipment
onto which is to be installed, as well as applicable local, state
and national regulations and industry standards and
accepted practices regarding safety of personnel and the
equipment safety should be permitted to install, maintain or
operate this device.  These instructions are provided only as
a general guide to such qualified persons and are not all-
inclusive.  They do not cover every application or circum-
stances which may arise in the installation, maintenance or
operation of this equipment.  Users are advised to comply
with all local, state and national regulations and industry
standards and accepted practices regarding safety of
personnel and the equipment safety.

Summary of Contents for DeviceNet E50DNA

Page 1: ...y and longest life expect ancy for Industrial Limit Switches INSTALLATION WARNING DO NOT INSTALL OR PERFORM MAINTENANCE ON THIS DEVICE WHILE THE CONTROLLER IS ENERGIZED DEATH OR SEVERE PERSONAL INJURY...

Page 2: ...embly Push Operational Head OPERATING HEADS WOBBLE STICK These spring return top operated heads use different rod type operators to detect motion in any direction perpendicu lar to the operator The op...

Page 3: ...030 in 0 290 in 4 lbs 8 oz B E50DS3 0 200 in 0 130 in 0 320 in 5 lbs 5 lbs B E50DH1 0 040 in 0 020 in 0 280 in 4 lbs 8 oz C E50DT1 0 040 in 0 020 in 0 280 in 4 lbs 8 oz C E50DT2 0 040 in 0 020 in 0 2...

Page 4: ...er Netview configuration software is a function to locate nodes by continually flashing the Module Network Status LED between green and red Once the Netview configuration software is communicating to...

Page 5: ...n line but not allocated Green by a master Flashing Device has detected a recoverable fault or a connection Red is in the timed out state Solid Device has detected an unrecoverable fault or is in the...

Page 6: ...de Rotary Operator Top Pushbutton Side Push Operators Top Pushbutton Adjustable Side Pushbutton Maintained Top Pushbutton Adjustable Side Pushbutton Side Push Roller 1 1 1 Can accommodate both U S 29...

Page 7: ...Switch state represents the physical location of the limit switch Head Actuation Count increments each time the head is actuated When Head Actuation Count reaches 80 or 100 of the Max Head Actuation C...

Page 8: ...s UINT Timestamp UINT Test Object Class 199 C7HEX Instance 1 Attribute Attribute ID Access Power OK 5 Get LED Disable 6 Get Set SOFTWARE TIMING The E50 is not capable of responding to all DeviceNet me...

Reviews: