background image

Table of Contents   

 

3

Table of Contents 

Introduction.......................................................................................................................................4 

Introduction .................................................................................................................................... 5 
Installing Drivers ............................................................................................................................ 6 
Downloading Drivers to a PanelMate Unit..................................................................................... 7 

Serial Transfer Cables ................................................................................................................ 7 

Memory Ranges.............................................................................................................................. 9 
Read-only Registers and Memory Ranges...................................................................................... 9 

Possible Configurations ..................................................................................................................10 

Direct Connection......................................................................................................................... 11 
Serial Communication Card.......................................................................................................... 12 

Serial Card Connection ............................................................................................................ 12 
R-Net Connection..................................................................................................................... 12 

Cabling.............................................................................................................................................13 

Cable Configurations.................................................................................................................... 14 

RS232C Cabling for Reliance PLCs ........................................................................................ 14 

Communication Parameters ..........................................................................................................15 

Standard Communications Parameters ......................................................................................... 16 

Serial Communication Card ..................................................................................................... 16 
R-Net Gateway Switch Locations ............................................................................................ 16 
Gateway Switch Settings.......................................................................................................... 17 
Baud Rate Selection ................................................................................................................. 17 
Port Configuration.................................................................................................................... 17 

Word and Bit References ...............................................................................................................18 

Word Referencing Method ........................................................................................................... 19 

Examples .................................................................................................................................. 20 

Maintenance Access ........................................................................................................................21 

Maintenance Access ..................................................................................................................... 22 

Index.................................................................................................................................................23 

 

 

 

Summary of Contents for Cutler-Hammer PanelMate

Page 1: ...PanelMate Reliance Communication Driver Manual Eaton Corporation Cutler Hammer Business Unit 811 Green Crest Drive Columbus OH 43081...

Page 2: ...Manufacturer is Eaton Corporation s Cutler Hammer Business Unit 811 Green Crest Drive Columbus OH 43081 TRADEMARKS PanelMate is a federally registered trademark of Eaton Corporation MS DOS Microsoft a...

Page 3: ......

Page 4: ...questions you can take advantage of our toll free line for technical assistance with hardware and software product selection system design and installation and system debugging and diagnostics Technic...

Page 5: ...ial Communication Card 12 Serial Card Connection 12 R Net Connection 12 Cabling 13 Cable Configurations 14 RS232C Cabling for Reliance PLCs 14 Communication Parameters 15 Standard Communications Param...

Page 6: ...4 Reliance Communication Driver Manual Introduction 1 In this chapter you will learn About driver installation How to download drivers to a PanelMate unit The supported memory types...

Page 7: ...ct to the PLC processor programming port All three types of connections use the same cable type and the node slot format for the Operator Station s PLC ID Each PLC is addressed by a node number and a...

Page 8: ...stalling Drivers PanelMate Configuration Editor software is installed using a CD ROM To install the drivers from the CD ROM select the Install Software option and then Install Drivers From the dialog...

Page 9: ...aded with Executive Firmware Choose the Driver tab Select the appropriate driver to be downloaded to the PanelMate Click the button labeled Add to Operation List Place the PanelMate unit in Serial Tra...

Page 10: ...8 Reliance Communication Driver Manual Cable P N 0818 PanelMate Power Series 1500 and PanelMate 500 only...

Page 11: ...0 2000 20000 77 3777 27777 40 0 00 1600 00 20000 00 177 17 17777 17 157775 17 0 1600 20000 177 17777 157775 40X 0 00 1600 00 20000 00 177 17 17777 17 157775 17 0 1600 20000 177 17777 157775 40E 0 00...

Page 12: ...10 Reliance Communication Driver Manual Possible Configurations 2 In this chapter you will learn How to connect an operator station to Reliance PLCs...

Page 13: ...n non volatile memory Since communications are direct the slot designation is always zero Example Processor ID 5 PanelMate PLC ID 5 0 An Operator Station connected directly to the programming port of...

Page 14: ...LC logic or by using a programming terminal Example Serial communications card in slot 2 processor in slot 1 PanelMate PLC ID 2 1 R Net is the network used by Reliance for its PLCs To access the netwo...

Page 15: ...Chapter 3 Cabling 13 Cabling 3 In this chapter you will learn The cabling requirements for Reliance PLCs...

Page 16: ...onnection RS232C Cabling for Reliance PLCs Operator Stations with female 9 pin DB 9S ports must have cables configured with male connectors DB 9P Note For PanelMate PC applications a female 9 pin conn...

Page 17: ...Chapter 4 Communications Parameters 15 Communication Parameters 4 In this chapter you will learn The different switch settings...

Page 18: ...he node number may be changed either by changing it in a program in the PLC or by means of a programming terminal R Net Gateway Switch Locations The port parameters may be set on the Gateway using the...

Page 19: ...Parity odd Default value Baud Rate Selection Baud Rate S1 6 S1 7 S1 8 110 Off Off Off 300 On Off Off 600 Off On Off 1200 On On Off 2400 Off Off On 4800 On Off On 9600 Off On On 19200 see S2 6 On On O...

Page 20: ...18 Reliance Communication Driver Manual Word and Bit References 5 In this chapter you will learn How to configure word and bit references...

Page 21: ...d See the Word and Bit References topic in the Configuration Software Online Help for a more detailed explanation of word and bit references including format descriptions The Reliance AutoMate PLCs us...

Page 22: ...iance Model 15 2533 Word 2533 of Reliance Model 20 21333 Word 21333 of Reliance Model 30 30E 163 Word 163 of Reliance Model 40 2051 Word 2051 of Reliance Model 40E Bit References Reference Description...

Page 23: ...Chapter 6 Maintenance Access 21 Maintenance Access 6 In this chapter you will learn How to use the Maintenance Template...

Page 24: ...t enter the correct mnemonics and numeric values and create a legal reference to change a reference Note When a new reference is entered on an Operator Station the Maintenance Template will remain in...

Page 25: ...G Gateway Switch Settings 17 I Installing Drivers 6 Introduction 5 M Maintenance Access 22 Memory Ranges 9 P Port Configuration 17 R Read only Registers 9 R Net Connection 12 R Net Gateway Switch Loc...

Page 26: ...described in this document Are the instructions easy to follow Are the examples helpful useful Are there enough examples Is the document organized logically Is it easy to find what you are looking fo...

Reviews: