background image

Page 24

IM05805016K

Effective October 2007

FIGURE #5

7

1

5

6

4

3

2

2

13

12

456

6A

78

8A

9

11

11

10

11

11

11

11

CB1

CB2

12

9

10

11

8

-

+

-

+

115

DVS

65

40

39

PRT

F

1

46

43

41

42

45

44

48

47

49

51
50

52

P12

F2

59

56

54

55

58

57

53

61
60

62

64

63

P7

P5

90

ERC

MMC

FS

71

69

67

68

70

66

74

73

75

77

76

72

P13

C2

84

82

80

81

83

78

79

88

87

86

89

85

ET

A

96

95

93

92

94

91

101

100

99

102

97

98

P14

CA

109

108

106

105

107

103

104

114

112

113

110

111

C3

C2

C1

C4

OMC

121

P15

119

118

120

116

117

127

125

126

122

123

124

C1

134

132

131

133

128

129

130

N2

N1

P16

35

35

P7

31

P11

29
30

28

27

P10

22

26

25

24

3

4

5

23

21

8

20
21

19

17

16

+

J3

J1

8A

6A

33

32

34

8A

P6

6A

+

-

P3

P2

38

37

36

38

36

37

P4

+

-

DVS

30

22

16

17

18

19

20

21

26

24

23

25

28

27

29

31

35

36

37

38

LLN

N

GD

B4

--

B6

LN

6A

8A

+

+

+

++

B6

--

B4

N

L

LOW FUEL

HIGH FUEL

LOW RES.

HIGH RES.

FUEL SPILL

LOW ROOM TEMP.

CHARGER #1 FAILURE

CHARGER #2 FAILURE

ENGINE RUN

HIGH ENGINE TEMP.

LOW OIL PRESS.

OVERSPEED

FUTURE #1

FUTURE #2

INTERLOCK

LOCAL STOP

REMOTE START

LOW SUCTION

DELUGE VALVE START

MERCOID SW INPUT

INPUT (BROWN)

COMMON (BLUE)

OUTPUT (WHITE)

TO TERMINAL BLOCKS

(CABLE P4)

USE TWO CABLES ON 24V 

CONTROLLERS

F

O

R CA

T

E

RP

ILLA

R E

N

GI

NE

S

 A

ND 

NE

W

E

R

 

EM

I EN

GI

N

E

S

 ON

L

Y

R

E

MO

VE

 B

O

TH

 JU

M

P

E

R

S J1 AN

D

 J3 

(C

ARD 5D15229H01 VE

4.

0 & ABO

V

E

PR

E

SSU

R

E

 

TR

A

N

SM

IT

TER

T

O

 TE

R

M

IN

AL

 BL

OC

K

S

(C

AB

LE P1

1)

NOTE:

1.

CO

NT

ACT

S

 A

R

RA

T

E

D

 F

O

R 10 

AM

PE

RES

 A

T

 120 

V

.

2.

P

U

MP

 HOUS

E

 T

R

OUB

L

E

 CONT

A

C

T

 M

U

S

T

 CLOS

E

 F

O

R A

L

A

R

M

.

3.

DC GROUND 

IS

 I

S

OLA

T

E

D

 F

R

OM CA

B

INE

T

 GROUND.

4.

RE

F

E

R T

O

 CONT

ROLLE

R

 NA

ME

P

L

A

T

E

 F

O

P

R

OP

E

R

 P

O

W

E

S

U

P

P

L

Y

 RE

QUI

R

E

M

E

N

T

S

T

H

IS

 D

IES

EL C

O

N

T

R

O

LL

ER

 D

R

A

W

S

 15AM

PS

 M

A

X

.

5.

F

O

R CA

T

E

RP

IL

LE

R E

N

GI

NE

S

 ONL

Y

.

6.

A

F

T

E

1987,

 MOS

T

 E

N

GI

N

E

 DID NOT

 RE

QUI

R

E

 T

H

E

 US

E

 OF

 T

E

RMINA

L

 #7.

 CONS

UL

T

 T

H

E

 

F

A

CT

OR

Y

 F

O

R MORE

 DE

T

A

ILS

 I

F

 R

E

QUI

R

E

D

.

W

IRI

N

G

 NOT

E

S

:

1  

UNLE

S

S

 OT

HE

R

W

IS

E

 NOT

E

A

LL 

W

IRING T

O

 B

E

 T

E

W

 #14 

A

W

G

|–

>

-->

 T

E

W

 #1

A

W

G

. (1.

29 MM

)

------

---- 

CUST

O

ME

R CO

NN

ECT

IO

N

S

 - 

SE

W

IRI

NG

 LA

BLE

 F

O

R S

IZ

E

S

RIBB

O

N

 CAB

L

E

TO

 P

L

A

S

T

IC

 

ME

MB

RANE

 

CO

NT

R

O

L

L

E

R

 P

A

D

RIBBON CABLE

RIBBON CABLE

TO ANNUNCIATOR 

CARD (CABLE P3)

TO P7 ON RELAY CARD 

(CABLE P7)

T

O

 P

R

IN

TE

R

 (

C

AB

LE 

P2)

CONTROLLE

R CARD

P

U

MP

 ROOM 

T

R

OUB

L

E

F

UT

URE

#1

F

U

T

URE

 #2

MA

NUA

MODE

F

U

E

L

 S

T

OP

GRA

N

K

 ON 

B

A

T

. #2

E

N

G

INE

 RUN

E

N

GI

NE

 T

R

OUB

L

E

 A

L

A

R

M

C

OM

MON 

A

L

A

R

M

DRA

IN V

A

L

V

E

 S

O

L

.

O

F

F

 M

O

DE

CRA

NK

 ON B

A

T

#1

RELA

Y

 CARD

T

O

 P

.B.

 ON 

F

A

CE

 P

L

A

T

E

 

(C

AB

L

E

 P5

)

T

O

 CONT

ROLLE

R

 CA

RD

 

(C

A

B

L

E P7

)

CRA

NK

 #1

CRA

NK

 #2

GRO

UND T

O

 

ENCL

OSURE

T

O

 CONT

ROL

L

ER 

CARD (

C

ABL

P4

)

T

O

 CONT

ROL

L

ER 

CARD 

(C

ABL

E P1

1

)

T

O

 CONT

ROL

L

ER CA

RD

 

(C

A

B

L

E

 P4

) US

E T

W

O

 

CABL

ES O

N

 2

4

V

 

CO

NT

RO

L

L

E

RS

COM

M

UNICA

T

ION 

(C

ABL

E P2

)

T

O

 CONT

ROL

L

ER 

CARD (

C

AB

L

E

 

P1

1

)

PRINTER

AC PO

WER SUPPL

1

5

A

 M

AXI

M

U

M

THIS

 CONT

ROL IS NEGA

T

IVE

 GROUND

GROUND
NEUTRAL
LINE

MERCOID SW. INPUT

DELUTE VALVE START

LOW SUCTION

REMOTE START

INTERLOCK

FUTURE #2

FUTURE #1

LOW ROOM TEMP.

FUEL SPILL

HIGH RES.

LOW RES.

HIGH FUEL

LOW FUEL

BA

T

T

ER

Y

 

IS

O

L

A

T

OR

SEE NO

TE 5

DIESEL ENGINE

F

U

EL

 & W

A

TER SO

L

E

NO

ID

 V

A

L

V

E

E

N

G

INE RUN SW

.

O

VERSP

EED SW

.

O

IL

 PRES

SURE SW

.

E

N

GI

NE

 W

A

T

E

R T

E

M

P

. S

W

.

BA

T

T

ER

Y #

1

 I

N

PUT

(+)

ENGINE AL

T

. CIRCUIT

(I

F

 REQ

.)

BA

TTER

Y

 #

2

 I

N

PUT

 (

+

)

BA

T

T

E

R

Y #

1

 CRANK

BA

T

T

E

R

Y #

2

 CRANK

B

A

T

T

ERI

ES (

)

FUEL

 SO

L

E

NO

ID

LO

C

A

L

 

ST

O

P

 P

.B.

BA

TT

ER

CH

A

R

GE

R

 #

2

BA

T

T

ER

CHARGER #

1

CABL

E SUPPL

IE

B

Y

 

PRINT

E

R M

A

NUF

ACT

URER

Summary of Contents for Cutler-Hammer FD100

Page 1: ...IM05805016K For more information visit www chfire com Diesel Engine Fire Pump Controllers Instructions...

Page 2: ......

Page 3: ...TIMER 4 6 PROGRAMMING OF THE MAIN CONTROLLER 4 6 1 TO PROGRAM THE CONTROLLER 4 6 2 PROGRAM DESCRIPTIONS 4 6 2 1 Change Date 5 6 2 2 Change Time 5 6 2 3 Weekly Timer 5 6 2 4 Run Period Timer 5 6 2 5 L...

Page 4: ...FIELD FAILURE ALARM SIMULATION 13 13 1 CHARGER FAILURE 13 13 2 BATTERY FAILURE 13 13 3 LOW OIL PRESSURE 13 13 4 HIGH ENGINE TEMPERATURE 13 13 5 ENGINE FAIL TO START 13 13 6 ENGINE OVERSPEED 13 13 7 OT...

Page 5: ...ine battery voltage and system pressure Inspect all electrical connections components and wiring for any visible damage and correct as necessary Ensure that all electrical connections are tightened be...

Page 6: ...reading of each battery as well as the system pressure in PSI The LCD display is also used while programming the diesel controller 4 2 Annunciators The alarm and status indicators are located in the t...

Page 7: ...ll further cranking 5 4 Stop Modes The Stop Mode is programmable for either Manual Stop or Auto Stop see Figure 2 Note that the engine can be stopped at any time by placing the controller in the OFF p...

Page 8: ...a few seconds delay will prevent the lead pump controller from responding to momentary hydraulic transient pressure loss which would otherwise start the fire pump unnecessarily The SST can be program...

Page 9: ...grammed determines at what pressure the controller will initiate a start command to the engine The pressure range is 1 500 PSI Factory default 1 PSI 6 2 8 Pressure Stop Point The value programmed dete...

Page 10: ...programming menu If selected as YES after exiting the program mode and pressing the Time Print button for 3 seconds the programmed parameters and selected controller readings will be printed This is...

Page 11: ...rger is fully electronic and will protect itself by shutting down during a continued short circuit The maximum current draw that the chargers will draw when operating at 100 charging rate is 12 Volt S...

Page 12: ...t on the load side of the charger In addition the charger will not operate if a battery is connected incorrectly or if the wrong voltage of battery is connected AC Input Fuse Protection The AC Supply...

Page 13: ...ly after applying power to the charger with DIP Switch 8 in the ON position and a battery connected When the charger is in the forced charge mode it will attempt to recover a battery by delivering 10...

Page 14: ...ll sound if system overpressure is present 11 Electronic Starting Engines ECM The FD100 diesel engine fire pump controllers are compatible with NFPA20 Section 12 4 1 3 for engines with ECM Electronic...

Page 15: ...ection 14 of manual Depress the AUTO button LED on AUTO button will light and Annunciator Switch in Auto will illuminate Ensure that water pressure is available and the LCD display on the Display Pane...

Page 16: ...d will energize and reduce pressure Controller will start engine automatically Engine Run annunciator illuminates Press OFF button Engine will stop NOTE Engine will stop if Low Oil Pressure High Water...

Page 17: ...rm will also indicate if terminal 4 is wired from the engine to the panel and the engine is not physically running 13 5 Engine Fail to Start ALL ENGINES EXCEPT CATERPILLAR 1 Disconnect field wires 9 1...

Page 18: ...el It is recommended that square and clean cut edge is used for entry of paper into the printer mechanism scissor cut preferred To load paper turn on the power Now feed the cut edge of the paper into...

Page 19: ...PRINTER UNTIL ALL MESSAGES ARE PRINTED OTHERWISE INFORMATION WILL BE LOST 14 5 Print Status When programmed as YES the printer will print the STATUS of the controller upon exiting the program mode and...

Page 20: ...stores See list below depicting the office supply stores and their respective catalog number for the paper NON TAPED ENDED ROLLS WILSONS LAB CR722 TAPED ENDED ROLLS STAPLES 14485 GRAND TOY 7767000 OFF...

Page 21: ...AKE INSTRUCTION FROM LCD DISPLAY HOLD BUTTON FOR AT LEAST 3 SEC THEN PRINTERWILL PRINT ANY AVAILABLE INFORMATION 4 FOR DETAIL AND SET UP REFERTO OPERATING MANUAL 5 TO MANUALLY STARTTHE DIESEL DEPRESST...

Page 22: ...REASE COUNT UNLESS OTHERWISE SHOWN DECREASE COUNT UNLESS OTHERWISE SHOWN INCREASE COUNT LANG ENGLISH YEAR 98 HOUR 15 DAY MON RPT MINUTES 30 PRES TRANS YES START 100 PSI STOP 110 PSI INPUT OUTPUT INPUT...

Page 23: ...t Current 11 A 11 A Battery Voltage 8 0V 18 0V 18 0 V 31 4 V Ambient Temperature 60 C 60 C Table 2 Threshold 12V Battery 24V Battery Bulk Overcharge Float Bulk Overcharge Float Min Max Min Max Min Max...

Page 24: ...Controller Panel Pressing RESET On Controller Panel Pump Room PRT Eliminate Problem and Press RESET MM DD YR HH MM SS Fuel Spill mode High Engine Temperature 5 Placing Controller in the OFF Mode Plac...

Page 25: ...rint MM DD YR HH MM SS Fuel Solenoid Open mode Low Pressure This message is printed when the controller is called upon to start the diesel engine as a result of low system pressure MM DD YR HH MM SS L...

Page 26: ...CB1 CRANK 2 CB2 Dimensions Standard Enclosure Type NEMA 2 12 NOTES 1 All enclosures finished in FirePump red 2 Cable entrance bottom only 3 Standard enclosure type NEMA 2 12 4 Enclosure made from 14...

Page 27: ...NECTION DIAGRAM IS SUITABLE FOR THE FOLLOWING DIESEL ENGINES CLARKE DETROIT DIESEL ALLISON MODELS DDFP O3DT DDFP L3DT DDFP T3DT JDFP O6WA JDFP O6WR DDFP T6FA DDFP O6FA DDFP O6FH DDFP L8FA DDFP O8FA DD...

Page 28: ...D IS ISOLATED FROM CABINET GROUND 4 REFER TO CONTROLLER NAMEPLATE FOR PROPER POWER SUPPLY REQUIREMENTS THIS DIESEL CONTROLLER DRAWS 15AMPS MAX 5 FOR CATERPILLER ENGINES ONLY 6 AFTER 1987 MOST ENGINE D...

Page 29: ...the bottom right side ONLY Compare rating nameplates on controller and engine All Electrical Connections are tight All Wiring to and from Controller is Correct Field Connections Remote Starters Fuel L...

Page 30: ...t value is 10 PSI Set Sequential Start Timer If required Set Stop Mode to either Manual or Automatic Enable Disable AC Failure Start Set Print Routine to Automatic This will be set back to manual when...

Page 31: ...Place the controller in the AUTO mode by depressing the AUTO button At the programmed date and time the drain valve solenoid will open and the pressure will drop The engine will run for a minimum of...

Page 32: ...Failure and Charger 2 Failure should illuminate after 3 minutes Reconnect AC power Press the OFF button to reset the alarms Fail to Start Place the controller in the AUTO mode by depressing the AUTO...

Page 33: ...Stop Point Low Pressure Alarm Pressure Deviation Sequential Start Timer If required Enable Disable Manual Stop as per requirements Enable Disable AC Failure Start If Required Print Routine When finish...

Page 34: ...Hammer 2256 29th Street NE 10 Calgary Alberta T1Y 7G4 Canada Tel 403 717 2000 Fax 403 717 0567 www chfire com 2007 Eaton Corporation All Rights Reserved Printed in Canada Publication No IM05805016K O...