GENERAL SAFETY INFORMATION

The following methods are used in this manual to alert the user to important information:-

WARNING !

Warnings are provided to ensure operator safety and MUST be followed .

CAUTION

Cautions are provided to prevent damage to the instrument.

NOTE

These are used to give general information to ensure correct operation.

SAFETY INSTRUCTIONS FOR INSTALLATION AND OPERATING PERSONNEL

The operating instructions provided here contain 

essential safety instructions

 for installation personnel and 

those engaged in the operation, maintenance and servicing of the equipment. 

WARNING !

Failure to comply with these instructions can endanger the lives or health of personnel and risk damage 
to the plant and the environment .

WARNING !

The responsibility for planning, installation, commissioning, operation and maintenance, particularly with 
respect to applications in explosion-hazard areas, lies with the plant operator .

Before commencing installation or commissioning:

•  Read and understand the contents of this manual and the product datasheet

•  Ensure installation and operating personnel have received adequate training for this task

•  Ensure that any operating instructions are fully understood by the personnel responsible.

•  Observe national and local installation and mounting regulations (e.g. IEC 60079-14).

WARNING !

If these assemblies have been used previously in general electrical installations,  

they MAY NOT be used in explosion-hazard area applications .

During operation:

•  Make the relevant instructions available at all times to the operating personnel.

•  Observe safety instructions.

•  Observe national safety and accident prevention regulations.

•  Operate the equipment within its published specification.

•  Servicing, maintenance work or repairs not described in this manual must not be performed without prior 

agreement with the manufacturer.

•  Any damage to this equipment may render its explosion protection null and void.

•  No changes to any of the components that might impair their explosion protection are permitted.

If any information provided here is not clear:

•  Contact Eaton’s MTL product line or one of its representatives.  

NOTE

Improper installation and operation of the enclosure can result in the invalidation of the guarantee.

Summary of Contents for Crouse-Hinds Megablock F300 Series

Page 1: ...F300 megablock range MTL fieldbus device couplers April 2022 INM F300 Rev 9 Instruction manual MTL fieldbus networks...

Page 2: ...tion of Conformity A printed version of the Declaration of Conformity has been provided separately within the original shipment of goods However you can find a copy of the latest version at http www m...

Page 3: ...r Requirements 4 5 2 Terminator 4 5 3 Trunk connections 4 5 4 Spur port connections 5 5 5 Surge protection 5 6 TESTING 6 6 1 Power LED 6 6 2 Spur LEDs 6 7 ROUTINE MAINTENANCE 6 8 ATEX UKCA SAFETY INST...

Page 4: ...this manual and the product datasheet Ensure installation and operating personnel have received adequate training for this task Ensure that any operating instructions are fully understood by the pers...

Page 5: ...fitted to any of the Megablock fieldbus terminals to provide protection against induced surges and transients that can potentially destroy or degrade certain components inside the F300 Megablocks 2 D...

Page 6: ...standard connector for the Megablock is a pluggable screw terminal elevator type Pluggable spring clamp connectors rely on constant spring pressure to maintain contact with the wire To order Megablock...

Page 7: ...then engage the DIN rail clips under the ledge of the DIN rail Push the Megablock against the edge of the rail then rotate the Megablock until it sits flat onto the DIN rail then release the pressure...

Page 8: ...that the T F97 molded logo is facing inwards towards the body of the Megablock otherwise difficulty will be experienced in accessing the spring clamp buttons to remove it For screw terminals loosen t...

Page 9: ...tor provides and cable screen S connections See section 5 5 for information on cable screen grounding Cable screen connections The S screen terminals for the trunk and the spurs are interconnected com...

Page 10: ...d tighten its securing screws 7 Repeat 5 and 6 for all the other FS32 modules A separate grounding bar F300 BAR is used for the trunk connector which must be similarly connected to ground see Figures...

Page 11: ...tice EN 60079 14 In addition particular industries or end users may have specific requirements relating to the safety of their installations and these requirements should also be met For the majority...

Page 12: ...ion and maintenance should be carried out in accordance with European national and local regulations which may refer to the standard EN 60079 17 In addition specific industries or end users may have s...

Page 13: ...9 INM F300 Rev 9 9 FM CONTROL DRAWINGS...

Page 14: ...10 INM F300 Rev 9...

Page 15: ...11 INM F300 Rev 9...

Page 16: ...eded by transient disturbances of more than 140 of the rated voltage 3 The apparatus shall only be installed in an area of at least pollution degree 2 as defined in IEC 60664 1 See footnote Ex ic IIC...

Page 17: ...13 INM F300 Rev 9 10 2 IECEx Control drawings F97 Megablock Part Numbers Wire Requirements Specific Conditions of Use...

Page 18: ...14 INM F300 Rev 9 F97 Megablock Part Numbers Wire Requirements Specific Conditions of Use...

Page 19: ...15 INM F300 Rev 9 F97 FISCO ic FNICO Installation Requirements Wire Requirements Specific Conditions of Safe Use Megablock Part Numbers...

Page 20: ...n Terminator and Connector Partition Terminator and Connector Installed Repair and Maintenance Certification Markings F3xx Partition Installation Connector Installation Terminator Installation DIN Rai...

Page 21: ...17 INM F300 Rev 9 11 CCC INSTRUCTIONS...

Page 22: ...18 INM F300 Rev 9...

Page 23: ...19 INM F300 Rev 9...

Page 24: ...20 INM F300 Rev 9...

Page 25: ...21 INM F300 Rev 9 THIS PAGE IS LEFT INTENTIONALLY BLANK...

Page 26: ...Old Mahabalipuram Road Sholinganallur Chennai 600 119 India Tel 91 0 44 24501660 24501857 Fax 91 0 44 24501463 E mail mtlindiasales eaton com ITALY MTL Italia srl Via San Bovio 3 20090 Segrate Milano...

Reviews: