background image

 

California Air Tools   

2.5 Gallon Pressure Pot   

 
 
Model No. 255C 
 
 
 
 
 
 

 

 
 
 
 
 
 
                                                                                                                           

Technical Data 

 

    Type of feed

…………………………………………………………………………….……Air Pressure (1/4”) 

    Maximum pressure in the tank

…………………………………………………………...…………… (80 PSI) 

    Working pressure in the tank

………………………………………………………………………..... (60 PSI) 

   

Tank capacity……………………………………………………………………………………..…......(2.5 gal) 

 

Summary of Contents for 255C

Page 1: ...California Air Tools 2 5 Gallon Pressure Pot Model No 255C Technical Data Type of feed Air Pressure 1 4 Maximum pressure in the tank 80 PSI Working pressure in the tank 60 PSI Tank capacity 2 5 gal ...

Page 2: ...r pressurization of Attachments Hazard What Could Happen How To Prevent It WARNING Explosion of objects Attachments whose pressure rating is lower than the adjusted pressure in the tank could explode resulting in serious injury or property damage Always make sure that equipment connected to tank has a higher pressure rating than the regulated air pressure tank WARNING When performing maintenance d...

Page 3: ... and parts can occur in order to better increase the performance of the product Air Compressor Use an air compressor that can produce at least 90 PSI 1 WARNING Ensure the air supply is clean and does not exceed 90psi while operating the tool Too high air pressure maybe dangerous causing damage or personal injury 2 Drain the air compressor air tank daily Water in the air line will damage the tool 3...

Page 4: ...ed air pressure 4 Now adjust the regulator on the pressure pot to obtain the desired air pressure for the material Maintenance and Storage 1 Close the air flow to the equipment 2 Release all air pressure in the tank by pulling the safety valve ring until the pressure subsides 3 Rotate the pressure pot regulator counterclockwise 4 Loosen the metal screws remove the wing nuts and open the lid to one...

Page 5: ...efore assembly PROBLEMS POSSIBLE CAUSES CORRECTION Air escaping from port on regulator cap Broken or damaged diaphragm in regulator Replace regulator Pressure dropping slowly on gauge Dirty or work valve seat in regulator Replace regulator Air leak at the lid gasket Defective lid gasket Thumb screw not tight Replace lid gasket Tighten thumb screws Gauge not registering air pressure Defective air g...

Page 6: ......

Page 7: ...arranty on those parts will expire coincident with the original product warranty Warranty valid for 12 months from date of purchase Receipt or invoice required to validate warranty This limited warranty shall NOT apply to and does NOT cover products that are in anyway subject to any of the following 1 Improper setup installation or storage 2 Lack of proper maintenance and service 3 Accident damage...

Reviews: