background image

3

2

EATON    

 IL504001EN

    

 Installation instructions

 

EATON    

 IL504001EN

    

 Installation instructions

 

Installation Instructions – CoviO Linear Cove System

Installation Instructions – CoviO Linear Cove System

INSTALLATION

1.

Optimize cove design detials.

ote:

N

To optimize cove lighting, cove design must be 

optimized.

Figure 1. 

Figure 2.1 

Figure 2.2 

Figure 3 

Figure 4 

Figure 5 

Figure 6.1 

Figure 6.2 

Table 1. 

1.7”

42 mm

Upper mounting 

channel

Bottom mounting 

channel

Female connector

Male Connector

Female Connector

Beginning of Run Power Connection 

Should Follow Wiring Chart Above

Line Voltage 

Power Feed 

(By Others)

15 degree 

mount

30 degree 

mount

Beginning 

of Run 

Power Cord

2. Plan run lengths and power drops per run

lengthspecifications below:

3. Unpack fixtures, cables, and mounting hardware from

boxes.

ote:

N

All installations require a beginning of run power cord 

with custom connector and junction box supplied by 

Eaton. Line voltage power supply line supplied by 

others. If your installation calls for the jumper cable 

accessory to add space between fixtures, make sure 

they are available.

1.8” 

46 mm

12” / 24” 

305 mm / 610 mm

1.8” 

46 mm

4. Prepare beginning fixture for line voltage input by

removing top screws to Wiring chart to be verified by

eng’g open junction box wiring compartment. Remove

cover of desired feed location and feed line voltage

power lead cable (by others) through hole. Trim power

feed to desired length. Connect power lead cable and

input driver wiring to female connector wires via wire

nuts. Green ground screw must be connected for safe

operation.

ote:

N

Minimum of 18 AWG power lead cable wires to be 

used.

5. Close junction box by tightening top screws.

Beginning 

of Run 

Power Cord

Beginning 

of Run 

Junction 

Box

Line Voltage 

Power Feed 

(By Others)

Beginning 

of Run Male 

Connector

WIRING CHART

* Fixtures utilize a Green Pigtail or a Green Through Wire for grounding.

HOT

NEUTRAL

GROUND *

CONTROL 1

CONTROL 2

Black

White

Green

Purple

Gray

6. Secure mounting clips with 2 screws in straight line at

least 2” from wall for optimal cove lighting.

Connector 

Location

Fixture 

Release Tab

Fixture 

Mounting 

Location

Mounting 

Holes

Top Mounting 

Clip

Bottom 

Mounting Clip

Mounting Stop 

For Vertical 

Mount

7.

If mounting angle is desired, place proper degree

mounting under the clip.

8. Snap male connector from beginning of run power feed

into female connector of the first fixture in the run.

Self closing cap of female connector must be opened

for connection. Connector must “click” to ensure

complete, proper connection.

Cove face and shield

2” (min.)

Fixture distance from

back of cove wall

6” (min.)

Distance from

ceiling plane

Align

CoviO Installation Run Length Specifications

       

Fixture Length  

(Total Lumen Output)

1F=12" 

(500lm)

Lumen Package

05L 

(500lm/ft)

10L 

(1000lm/ft)

15L 

(1500lm/ft)

Fixture Input Wattage

5.2W

10.2W

14.6W

Dimming Protocol

0-10V (STD) 

ELV (ELV) 

Triac (TR) 
WaveLinx (WL)

Maximum Interconnect 

Qty (PCS) @ 120V

140

70

50

Maximum Interconnect 

Qty (PCS) @ 277V

300

170

120

DALI (5LT)

Maximum Interconnect 

Qty (PCS) @ 120V

92

47

32

Maximum Interconnect 

Qty (PCS) @ 277V

216

110

76

Fixture Length  

(Total Lumen Output)

2F=24” 

(3000lm)

Lumen Package

05L 

(500lm/ft)

10L 

(1000lm/ft)

15L 

(1500lm/ft)

Fixture Input Wattage

10.2W

19.0W

28.9W

Dimming Protocol

0-10V (STD) 

ELV (ELV) 

Triac (TR) 

WaveLinx (WL)

Maximum Interconnect 

Qty (PCS) @ 120V

70

35

25

Maximum Interconnect 

Qty (PCS) @ 277V

170

85

60

DALI (5LT)

Maximum Interconnect 

Qty (PCS) @ 120V

46

25

16

Maximum Interconnect 

Qty (PCS) @ 277V

110

59

38

Summary of Contents for CoviO

Page 1: ...to sharp edges handle with care Failure to comply with these instructions may result in death serious bodily injury and property damage WARNING DISCLAIMER OF LIABILITY Eaton assumes no liability for damages or losses of any kind that may arise from the improper careless or negligent installation handling or use of this product IMPORTANT Read carefully before installing fixture Retain for future re...

Page 2: ... Close junction box by tightening top screws Beginning of Run Power Cord Beginning of Run Junction Box Line Voltage Power Feed By Others Beginning of Run Male Connector WIRING CHART Fixtures utilize a Green Pigtail or a Green Through Wire for grounding HOT NEUTRAL GROUND CONTROL 1 CONTROL 2 Black White Green Purple Gray 6 Secure mounting clips with 2 screws in straight line at least 2 from wall fo...

Page 3: ...es to assure alingnment between fixtures within the cove Connectors have 2 standoffs to align with the cove wall and optimize cove lighting performance 2 10 Install fixture into mounting by making sure mounting channel in the bottom of the fixture engages with the mounting clip Fixture can then be rotated into place making sure the top clip engages in the upper mounting channel to secure fixture i...

Page 4: ...terference 2 This device must accept any interference received including interference that may cause undesired operation Note The grantee is not responsible for any changes or modifications not expressly approved by the party responsible for compliance Such modifications could void the user s authority to operate the equipment Note The equipment has been tested and found to comply with the limits ...

Reviews: