3
2
EATON
IL504001EN
Installation instructions
EATON
IL504001EN
Installation instructions
Installation Instructions – CoviO Linear Cove System
Installation Instructions – CoviO Linear Cove System
INSTALLATION
1.
Optimize cove design detials.
ote:
N
To optimize cove lighting, cove design must be
optimized.
Figure 1.
Figure 2.1
Figure 2.2
Figure 3
Figure 4
Figure 5
Figure 6.1
Figure 6.2
Table 1.
1.7”
42 mm
Upper mounting
channel
Bottom mounting
channel
Female connector
Male Connector
Female Connector
Beginning of Run Power Connection
Should Follow Wiring Chart Above
Line Voltage
Power Feed
(By Others)
15 degree
mount
30 degree
mount
Beginning
of Run
Power Cord
2. Plan run lengths and power drops per run
lengthspecifications below:
3. Unpack fixtures, cables, and mounting hardware from
boxes.
ote:
N
All installations require a beginning of run power cord
with custom connector and junction box supplied by
Eaton. Line voltage power supply line supplied by
others. If your installation calls for the jumper cable
accessory to add space between fixtures, make sure
they are available.
1.8”
46 mm
12” / 24”
305 mm / 610 mm
1.8”
46 mm
4. Prepare beginning fixture for line voltage input by
removing top screws to Wiring chart to be verified by
eng’g open junction box wiring compartment. Remove
cover of desired feed location and feed line voltage
power lead cable (by others) through hole. Trim power
feed to desired length. Connect power lead cable and
input driver wiring to female connector wires via wire
nuts. Green ground screw must be connected for safe
operation.
ote:
N
Minimum of 18 AWG power lead cable wires to be
used.
5. Close junction box by tightening top screws.
Beginning
of Run
Power Cord
Beginning
of Run
Junction
Box
Line Voltage
Power Feed
(By Others)
Beginning
of Run Male
Connector
WIRING CHART
* Fixtures utilize a Green Pigtail or a Green Through Wire for grounding.
HOT
NEUTRAL
GROUND *
CONTROL 1
CONTROL 2
Black
White
Green
Purple
Gray
6. Secure mounting clips with 2 screws in straight line at
least 2” from wall for optimal cove lighting.
Connector
Location
Fixture
Release Tab
Fixture
Mounting
Location
Mounting
Holes
Top Mounting
Clip
Bottom
Mounting Clip
Mounting Stop
For Vertical
Mount
7.
If mounting angle is desired, place proper degree
mounting under the clip.
8. Snap male connector from beginning of run power feed
into female connector of the first fixture in the run.
Self closing cap of female connector must be opened
for connection. Connector must “click” to ensure
complete, proper connection.
Cove face and shield
2” (min.)
Fixture distance from
back of cove wall
6” (min.)
Distance from
ceiling plane
Align
CoviO Installation Run Length Specifications
Fixture Length
(Total Lumen Output)
1F=12"
(500lm)
Lumen Package
05L
(500lm/ft)
10L
(1000lm/ft)
15L
(1500lm/ft)
Fixture Input Wattage
5.2W
10.2W
14.6W
Dimming Protocol
0-10V (STD)
ELV (ELV)
Triac (TR)
WaveLinx (WL)
Maximum Interconnect
Qty (PCS) @ 120V
140
70
50
Maximum Interconnect
Qty (PCS) @ 277V
300
170
120
DALI (5LT)
Maximum Interconnect
Qty (PCS) @ 120V
92
47
32
Maximum Interconnect
Qty (PCS) @ 277V
216
110
76
Fixture Length
(Total Lumen Output)
2F=24”
(3000lm)
Lumen Package
05L
(500lm/ft)
10L
(1000lm/ft)
15L
(1500lm/ft)
Fixture Input Wattage
10.2W
19.0W
28.9W
Dimming Protocol
0-10V (STD)
ELV (ELV)
Triac (TR)
WaveLinx (WL)
Maximum Interconnect
Qty (PCS) @ 120V
70
35
25
Maximum Interconnect
Qty (PCS) @ 277V
170
85
60
DALI (5LT)
Maximum Interconnect
Qty (PCS) @ 120V
46
25
16
Maximum Interconnect
Qty (PCS) @ 277V
110
59
38